Dental Diagnosis Equipments Main strong points and function:
1. Compact control panel with intuitive symbols.
2. X-ray controls via keypad with spiral cable.
3. Optional remote control keypad.
4. Constant potential high-frequency multi-pulse X-ray generator.
5. Focal spot 0.5 IEC 336
6. Voltage at anode:61-85kV
7. Current at anode:4-10mA
8. Exposure time: panoramic 15s maximum, cephalometric 9 to 12s
9. Heating load management for minimum waiting time.
10. Removable CCD Sensor
11. Image height 22cm
12. Spatial resolution>5line pairs per mm
13. Acquisition dynamics 12 levels
14. Imaging area of 15X30 cm on Panoramic and 22x24cm on Ceph
USB interface
Dental Diagnosis Equipments Technical data
No | Photo | Item | Technology Parameter | |||
1 | Generator | Output Power: 32kW | ||||
High frequency output: 25kHz | ||||||
kVp Range: 40-150 KV | ||||||
mA Range: 10-400mA | ||||||
Exposure Timer Range: 0.001-6.3s (maximum) | ||||||
mAs Range (non-AEC): 1.5-630mAs | ||||||
Anatomical Programs (APR): yes | ||||||
Options: AEC, DAP | ||||||
Input Phase / Voltage: 3 phase, AC380V±10%, 50±1Hz | ||||||
2 | X-ray Tube | Nominal focal spot value: 0.6mm (small focus)/1.2mm (large forcus) | ||||
Rotation speed (min-1): 2700rpm@50Hz, 3200rpm@60Hz | ||||||
Maximum tube voltage: 150kV | ||||||
Maximum filament current: 370mA (small focus) / 760mA(large focus) | ||||||
Anode Heat Content: 150kHU (111KJ) | ||||||
Max rating (0.1s) (kw): 20/46kW@50Hz, 22/50kW@60Hz | ||||||
3 | Radiographic table | Focal spot to tabletop/wall stand: 1100mm (min) | ||||
Stand | Tube vertical travel range:750mm | |||||
Tube transverse travel range: 1250mm | ||||||
Tube rotation around table column: ±135°± 2° | ||||||
Tube rotation about the horizontal axis:+180° to -180°, locked at each 0°, 90°, 180°, 270° | ||||||
Table | Standard table top size: L2200mm×W785mm | |||||
Table height: 690mm | ||||||
Table top travel, longitudinal: 1000mm (min) | ||||||
Table top travel, transverse: 160mm (min) | ||||||
Gird | Size: 388mm×464mm (15"×18") | |||||
R=10:1, f=100cm, N=40 line/cm | ||||||
4 | Collimator | Control method: Manual | ||||
Maximum X-ray field coverage range: 43cm*35cm | ||||||
The average brightness of the light field: >150lux | ||||||
Input power: 24V AC, 10A | ||||||
5 | Wall stand | Minimum focal spot height: 800mm | ||||
Vertical height: 2000mm | ||||||
Vertical travel range: 1000mm (min) | ||||||
Film size: 8"×10",10"×12",11"×14",14"×14", 12"×15", 14"× 17" | ||||||
Grid | Size: 388mm×464mm (15"× 18") | |||||
R=10:1, f=180cm, N=40 line/cm |
1.Light and handy design allows easy mobilization and convenient operation.
2.Rocker arm can be self-balanced, easy for miving, operation and control.
3.Possess double control radiographic function ; safety and efficiency are both taken into consideration.
4.This mobile DR possesses the advanced panel detecting technology.
5.Fast and high quality imaging.
Welcome to contact for more information regarding our Dental Diagnosis Equipments :)
Certificate:
Our team:
Orich high frequency dental instrument, x ray machine CE Package:
Our Service.
1)Product Training To Our Clients By Our Technical Engineer In Our Factory.
2)Our Engineers Overseas Training And Installing Orich high frequency dental instrument, x ray machine CE .
3)One To One Service In Overseas Market.
Welcome your inquiries on Orich high frequency dental instrument, x ray machine CE and You are warmly and sincerely welcomed to ORICH factory!
ORICH, ALL REACH!