The CDI-E102-series inverter is a classic-type low-power inverter with optimum SVC and V/F control, stable performance and simplified functions. It reserves the configuration most-frequently used by users, and is more cost-effective.
Different Series to Choose
Item |
Specification |
|||
Control |
Control mode |
V/F Control Open-loop Vector Control (SVC) Closed-loop Vector Control (VC)( Invalid CDI-E100 Series) |
||
Frequency Resolution |
Digital: 0.02% Analog: 0.1% |
|||
V/F curve |
Linear, square root, random V/F |
|||
Overload Capability |
G Model: 60s for 150% of the rated current; 3s for 180% of the rated current; P Model: 60s for 120% of the rated current; 3s for 150% of the rated current; |
|||
Start Torque |
G Model: 0.5Hz/150% (SVC); 0Hz/180% (VC) P Model: 0.5Hz/100% |
|||
Speed Regulation Range |
1:100(SVC) |
1:1000(VC) |
||
Stable Speed Accuracy |
±0.5%(SVC) |
±0.02%(VC) |
||
Torque Control Accuracy |
±5%(VC) |
|||
Torque Compensation |
Manual torque compensation (0.1%~30.0%), automatic torque compensation |
|||
Configuration |
Control power supply P24V |
E100 |
Max. Output Current 300mA with current-limiting protection |
|
E102 |
Max. Output Current 300mA without current-limiting protection |
|||
E180 |
Max. Output Current 300mA with current-limiting protection |
|||
Input Terminal |
E100 |
6-way Digital Input Terminal (DI1~DI6), in which D16 can access to high-speed Impulse Input (both built-in and external power supply are available). 2-way Analog Input Terminal (VF1, VF2), which can be used as voltage (0V~10V) or current (0/4mA~20mA) input. It can be used as Digital Input Terminal through reference. |
||
E102 |
5-way Digital Input Terminal (DI1~DI6), in which D16 can access to high-speed Impulse Input (only internal power supply is available) 2-way Analog Input Terminal (VF1, VF2), which can be used as voltage (0V~10V) or current (0/4mA~20mA) input. It can be used as Digital Input Terminal through reference. |
|||
E180 |
6-way Digital Input Terminal (DI1~DI6),in which DI6 can access to high-speed Impulse Input. Through external I/O expansion card, it can be expanded to 4-way(DI7~DI10). 2-way Analog Input Terminal (VF1, VF2), which can be used as voltage (0V~10V) or current (0/4mA~20mA) input. It can be used as Digital Input Terminal through setting NOTE: Both internal power supply and external power supply can be used for DI1~DI6, only internal power supply can be used for DI7~DI10. |
Item |
Specification |
||
Configuration |
Output Terminal |
E100 |
2-way Analog Input Terminal (FM1, FM2), which can not only be used as output voltage (0V~10V),but output current (0mA~20mA) 1-way open collector output (YO), DC 48V 50Ma below 1-way Impulse output (FMP), Frequency Range between 0.01kHz~100.00kHz 2-way Relay Output (T1, T2), DC 30V/3A below and AC 250V/3A below Note: YO and FMP are common YO/FMP terminal, but only one can be used at the same time. |
E102 |
1-way Analog Input Terminal FM1, which can not only be used as output voltage (0V~10V),but output current (0mA~20mA). 1-way Relay Output T1, DC 30V/3A below and AC 250V/3A below |
||
E180 |
2-way Analog Input Terminal (FM1, FM2), which can not only be used as output voltage (0V~10V),but output current (0mA~20mA) 1-way open collector output (YO), DC 48V 50Ma below. Additional 2-way open collector output (YO1, YO2) can be added through external IO expansion card. 1-way Impulse output (FMP), Frequency Range between 0.01kHz~100.00kHz 2-way Relay Output (T1, T2), DC 30V/3A below w and AC 250V/3A below Note: YO and FMP are common YO/FMP terminal, but only one can be used at the same time. |
||
Running |
Operating mode |
Keyboard, terminal, RS485 communication |
|
Frequency Source |
14 kinds of main frequency sources and 14 kinds of auxiliary sources. Adopt various combination modes to switch. Diversification to Each Frequency Source Input Mode: keyboard potentiometer, external analog, digital reference, impulse reference, Multiplex Directive, simple PLC, communication, arithmetic results, etc. |
||
Torque Source |
14 kinds of Torque Sources, including digital reference, external analog, impulse reference, Multiplex Directive, communication, arithmetic results, etc. |
||
Acceleration and Deceleration Time |
Four groups of straight lines (select the terminal to switch through acceleration and deceleration time), S Curve 1 and S Curve 2 |
||
Emergency stop |
Interrupt output of frequency inverter. |
||
Multiplex Speed |
16 speed is allowable to set at most and use various combination of multiplex directive terminal to switch |
||
Simple PLC Function |
Continuously run 16-phase speed and independently set acceleration and deceleration time and running time |
||
Jogging Control |
Independently set Jogging frequency and jogging acceleration and deceleration time, additionally, set the unit under running state and confirm whether the jogging is preferential |
||
Rotating Speed Tracking |
Frequency inverter starts operation by tracking the load speed |
||
Fixed-length and Fixed-distance Control |
Realize fixed-length and fixed-distance control function through Impulse Input |
Item |
Specification |
|
Running |
Control mode |
Realize counting function through Impulse Input |
Wobbulating Function |
Apply for textile winding equipment |
|
Built-in PID |
Realize process control closed loop system |
|
AVR Function |
When the gird voltage fluctuates, ensure constant output |
|
DC Braking |
Realize fast and stable shut-down |
|
Slip Compensation |
Compensate the speed deviation caused by the increase of load |
|
Hopping Frequency |
Prevent resonance from occurring with load |
|
Sagged Function |
Balance the load of multiple motors with same load |
|
Timing Control |
Be able to realize automatic shutdown of the frequency inverter when reaching given time |
|
Built-in Virtual Delay Relay |
Realize simple logic Programming to multi-functional output terminal function and digital input terminal signal, the logic results can not only be equivalent to digital input terminal function, but can be output through multi-functional terminal output |
|
Built-in Timer |
Build in 2 timers and acquire the timing input signal to realize timing signal output. Use alone or in combination |
|
Operation Module Built-in Operation Module |
One built-in 4-way Operation Module to realize simple addition, subtraction, multiplication and division, size judgment and integral operation |
|
Communication |
E100 |
The control panel is directly equipped with RS485 Communication Interface and supports Standard MODBUS Protocol |
E102 |
The control panel is not equipped with built-in RS485 Communication Interface, so external communication expansion card is required. It supports Standard MODBUS Protocol (External Connection of E102-485 Expansion Card) |
|
E180 |
The control panel is not equipped with built-in RS485 Communication Interface, so external communication expansion card is required. It supports Standard MODBUS Protocol (External Connection of E180-485 Expansion Card) |
|
Encoder |
E100 |
Be able to connect the encoder through Terminal DI5 & DI6 on control panel, such an encoder connection method can realize simple closed-loop control through PID Control and used for occasions without high requirements to control accuracy. |
E102 |
Only connect to 1-way pulse signal of encoder (DI6) |
|
E180 |
The control panel is not equipped with encoder interface, so external encoder expansion card is required. It supports ABZ Incremental Encoder, UVW Incremental Encoder and Rotary Transformer. This encoder connection method can realize high-performance closed-loop vector control and be used for occasions with high requirements to control accuracy. |
|
Type of Motor |
E100 |
Only be equipped with asynchronous motor |
E102 |
Only be equipped with asynchronous motor |
|
E180 |
Not only be equipped with asynchronous motor, but synchronous motor |
1.Simplified Functions and More Cost-effective
Optimized configuration according to the functions most-frequently used by users, so as to reduce resource waste, improve cost performance and competitiveness.
2.Compact Structure
Optimum structure and elegant appearance; can be installed through both slides and holes; easy to use.
3.Flexible Type Selection
The 15kW or below types have standard internal brake units, and the 18.5-22kW types can have optional internal brake units. The 11kW, 15 kW types have standard DC inductors, and 18.5-22kW types can have optional DC inductors
Mainly applies to low-power non-VC situations with demanding requirements for input/output.
Die-cutting machine, carving machine, textile machine, glass-making machine and dyeing machine.
External keyboard and external extended line.
-------------------------------------------------------------------------------------------------------------
Q: Are you trading company or manufacturer ?
A: We are factory.
Q: How long is your delivery time?
A: Generally it is 1-2 weeks if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is also according to quantity.
Q: Do you provide samples?