DC12V 41.6A switching power supply 500W SMPS
OUTPUT | DC VOLTAGE | 12V | 15V | 24V | 36V | 48V | |
OUTPUT POWER | 500W | 500W | 500W | 500W | 500W | ||
CURRENT RANGE | 41.6A | 33.3A | 20.8A | 13.8A | 10.4A | ||
RIPPLE & NOISE(max.) | 150mVp-p | 200mVp-p | 200mVp-p | 300mVp-p | 300mVp-p | ||
VOLTAGE ADJ. RANGE | ±10% | ||||||
LINE REGULATION | ±1.0% | ||||||
LOAD REGULATION | ±2.0% | ||||||
VOLTAGE TOLERANCE | ±2.0% | ||||||
SETUP,RISE TIME | 800ms, 50ms at full load | ||||||
HOLD UP TIME | 60ms | ||||||
INPUT | VOLTAGE RANGE | 180 ~ 264VAC (110VAC input can be custom-made) | |||||
AC CURRENT(Typ.) | 7A/115V 3.5A/230V | ||||||
FREQUENCY RANGE | 47-63Hz | ||||||
EFFICIENCY(Typ.) | 78% | 78% | 80% | 82% | 82% | ||
INRUSH CURRENT(Typ.) | 18A/115V 36A/230V | ||||||
LEAKAGE CURRENT | <3.5mA/240VAC | ||||||
PROTECTION | OVER LOAD | 115%~135% of rated output voltage | |||||
SHORT CIRCUIT | voltage off and reset input for recovers | ||||||
ENVIRONMENT | WORKING TEMP. | -0℃ ~ +45℃ (Refer to output load derating curve) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP.,HUMIDITY | -20℃ ~ +85℃ 10~95% RH | ||||||
TEMP. COEFFICIENT | ±0.05%/℃ | ||||||
COOLING METHOD | BY FAN | ||||||
SAFTY & EMC | WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC, I/P-FG:1.5KVAC, O/P-FG:0.5KVAC | |||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG,O/P-FG: 100M Ohms/ 500VDC | ||||||
SAFTY STANDARDS | Refer to CE EN60950-1 | ||||||
EMC STANDARDS | Refer to EN55022,EN55024,EN61000 | ||||||
OTHERS | DIMENSION | L240*W125*H65MM | |||||
WEIGHT | 12PCS/Carton/17KG | ||||||
SHELL MATERIAL | Aluminium |