1)Center Number | | |
Text command | Parameter | Sample |
CENTER Add | 710#number# | 710#13500135000# |
| 711#number# | 711#13800138000# |
CENTER Del | D01# | D01# |
| D02# | D02# |
Command Description | 1)Center number can control the oil and power and resume factory settings | |
| 2) Center number can receive the call and text of vibration alarm and over speeding alarm. | |
| 3) SIM must display the income call number to control oil and power. | |
| 4) Only 2 number can be center number. | |
| 5) Change center number must resend the command. | |
| 6)Add new center number by CETNER,A, and delete by CENTER,D | |
Command Feedback | Successful Setting:Add admin account 1 OK! | |
2) View Center Number | | |
Text command | Parameter | Sample |
View | 901# | |
Command Description | This directive is used to view Device Manager number. | |
Command Feedback | Successful Setting:Admin1: | |
| Admin2: | |
5)APN Setting | | |
Text command | Parameter | Sample |
APN Setting | 802#username#account#password# | 1:802#intenet#123#123# |
| | 2: 802#internet# |
Command Description | APN differs according to the local telecom operators. | |
| For example:APN request password,please refer to Sample 1,and Sample 2 for no password. | |
Command Feedback | Successful Setting:SET APN OK! | |
6) Set Server | | |
Text command | Parameter | Sample |
SERVER Parameter | 803#SERVER # port# | 1:803#gps.dyegoo.net#6100# |
| | 2: 803#47.90.39.27#6100# |
View SERVER | CIP# | 1)CIP# |
Command Description | Change the IP and port when move to a new server | |
| port:10~65535 | |
| | |
Command Feedback | Successful Setting:set IP OK! | |
7)Moving Time Interval | | |
Text command | Parameter | Sample |
TIMEER Parameter setting | 730#uploading interval# | 730#20# |
Command Description | Time scope:0,10~60 seconds; 0,no data uploading; | |
| 10~60,means time interval;the default value is 15 seconds! | |
Command Feedback | Successful Setting:SET TIMER OK! | |
8)Static Time Interval | | |
Text command | Parameter | Sample |
STATIC | SUP#time interval# | SUP#5# |
Command Description | Timescope:1~60 minutes;The device has | |
| 3D transmission and the default time interval are 5 minutes. | |
Command Feedback | Successful Setting:SET STATIC TIME OK! | |
9) Cancel the continuous upload | | |
Text command | Parameter | Sample |
NUP | NUP# | NUP# |
Command | This command is used to cancel sending data to the platform | |
Description | If need again to restore the upload , you need to send TIMEER Parameter setting. | |
Command Feedback | SET OK! | |
10)Oil-Cut | | |
Text command | Parameter | Sample |
RELAY Parameter1 | 222# | 222# cut off oil and power |
RELAY Parameter2 | 333# | 333# recover oil and power |
| 1)RELAY control the start and closeness of the relay | |
Command Description | 2) Only the center number can operate. | |
| 3)the device only cut off the oil circuit on the condition of the driving speed below 20KM/H or in static state. | |
| 4)When send the command, the device will reply “please waiting “When the vehicle speed is over 20KM/H, the device will cut off the oil or the power when the speed below 20KM/H. | |
| Successful Setting:Fuel cut has already been completed OK! | |
Feedback | | |
11)GMT | | |
Text command | Parameter | Sample |
GMT | 801#location, time# | 801#E8# |
Command Description | The default time zone is Beijing time. If time zone need revised, please operate according to the above command. | |
Command Feedback | Successful Setting:Set time zone ok! | |
12)Vibration Alarm | | |
Text command | Parameter | Sample |
Open Vibration Alarm | 911# | 911# |
VIBRATION Parameter | 123#sensitivity#alarming way# | 1) 123#2#3# |
Set into | V123#2# | 1) V123#2# |
vibration alarm time | | 2) V123#1# |
Cancel vibration | 456# | 456# |
alarm | | |
Command Description | the sensitivity value of the vibration is from 1 to 5,1is the most sensitive and o is close. Alarming ways: 1, calling 2, texting, 3 calling and texting. | |
| Must set the center number and receiving number. | |
Command Feedback | set vibration alarm level,OK! | |
13)Speed Alarm | | |
Text command | Parameter | Sample |
SPEEDING Parameter | SSA#speed#alarm way# | 1) SSA#120# |
| Or | 2) SSA#150#3# |
| 667# speed#alarm way# | 1) 667#120# |
| | 2) 667#150#3# |
| The speed scope is form 60-220, if the speed is no this cope, the alarm is off. | |
| Alarming :1, calling 2, texting, 3 calling and texting. | |
| Must set the center number and receiving number. | |
Command Feedback | Successful Setting:set speeding alarm,OK! | |
14)ACC Alarm | | |
Text command | Parameter | Sample |
Open ACC | 840#1# | 840#1# |
Alarm | | |
Close ACC | 840#0# | |
ALARM | | |
Command Description | 1) When ACC is on, it cannot be turned on, SMS reply: Set up fail, please turn off ACC (set up fail! pls turn off ACC) 2) Alarm method: 1-Phone + platform, 2- SMS + platform. , 3-Phone + SMS + platform. The interval between two alarms is 3 minutes. | |
15)Reset | | |
Text command | Parameter | Sample |
RESET | 930# | 930# |
Command Description | Reset the device | |
Feedback | Successful Setting:Reset system, ok! | |
| | |
16)Factory | | |
Text command | Parameter | Sample |
Parameter | 940# | 940# |
Description | Restore the factory setting | |
| Only center number can initial this function | |
| Factory setting will recover to the original setting | |
Feedback | Successful Setting:FACTORY OK! | |
17)Language Setting | | |
command | Parameter | Sample |
LANG Parameter | LANG1# | LANG1# 1:CHINESE, |
| LANG0# | LANG0#:ENGLISH |
Command Description | ;When check the location, it will reply the Chinese location in Chinese language setting; while reply the URL link when in English language setting. | |
Feedback | Successful Setting:SET LANG OK! | |
18) GEO-fence Setting | | |
Text command | Parameter | Sample |
Setting | 920#radius#way# | 920#1#2# |
Cancel | 921# | 921# |
Command Description | Setting Geo-fence alarm, radius from 1-100, Unit:100M. | |
| Alarming :1, calling 2, texting | |
| Out Geo-fence 1 time, the Geo-fence canceled. | |
Feedback | Set Enclosure-2 OK / Cancel Enclosure OK | |
18)Position | | |
Text command | Parameter | Sample |
command | 988# | 988# |
Command Description | Check the longitude and altitude and other information of the device | |
Command Feedback | Reply with longitude and altitude, speed and IMEL. | |
| | |
19)Google Link | | |
Text command | Parameter | Sample |
command | 666# | 666# |
Command Description | Check the location link of Google map | |
Command Feedback | | |
| http://maps.google.com/maps?q=N22.540885,E11306310.+ | |
| \ | |
| 9*-9*-5265 | |
20)Version | | |
Text command | Parameter | Sample |
VERSION | V00# | V00# |
Command Description | The command is to check the software version | |
Command Feedback | VERSION:Xxxx | |
| BUILD:2012-07-05 10:12 | |
| | |
21)Param Check | | |
Text command | Parameter | Sample |
PARAM | 886# | 886# |
+[‘ | | |
=、7410-0+ | | |
*+ | | |
Command Feedback | IMEI:351190012535936 | |
| APN : cmnet | |
| IP:IP and port | |
| TIMER: moving uploading interval | |
| STATIC: static uploading interval | |
| CENTER: center number | |
| LANG: language(CN/EN) | |
| GMT: time zone (E/W8) | |
22)Status Check | | |
Text command | Parameter | Sample |
STATUS | 902# | 902# |
Command Description | The command is designed for checking the device’s working status. | |
Command Feedback | External power:ON/OFF | |
| GSM Signal:HIGH/MIDDLE/LOW | |
| GPS:FIXED/UNFIXED | |
| RELAYER:DISABLE/ENABLE | |
| Vibrate Warning:ON/OFF | |
| Pause:ON/OFF | |
23) Monitor (Voice Surveillance)-CALL BACK(default) | | |
command | Parameter | Sample |
SSS# | SSS# | SSS# |
Description | Using Command Send this command to the tracker’s number, the tracker will call back to admin number. | |
24) Monitor (Voice Surveillance)-CALL | | |
command | Parameter | Sample |
Open Calling mode | SS1# | SS1# |
Return to Call back | SS0# | SS0# |