Enquiries
Message
Home > Products > Other
DRUL-971 Cable Type Radar Level Gage/Fuel Gauge Sending Unit (fuel level sensor)
  • DRUL-971 Cable Type Radar Level Gage/Fuel Gauge Sending Unit (fuel level sensor)

DRUL-971 Cable Type Radar Level Gage/Fuel Gauge Sending Unit (fuel level sensor)

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin:
Shandong, China
Brand Name:
Dorun
Model Number:
Guided Wave Radar Level Meter
NAME:
Guided Wave Radar Level Meter
Operating Frequency:
100MHZ-1.8GHz
Repeatability:
±2mm
Resolution:
1mm
Sampling:
the echo sampling 55 times/s
Response Speed:
>0.2s
Current Signal:
4...20mA
Accuracy:
<0.1%
Communication Interface:
HART communication protocol
Power:
24VDC(+/-10%)
Supply Ability
Supply Ability:
1000 Set/Sets per Month
Packaging & Delivery

Guided Wave Radar Level Meter

The basic principle of Guided wave radar is time travel, radar wave runs at the speed of light, running time can be transformed into level signal by electronic parts.Probe sends out high-frequency pulse and transmits along the cable probe or rod probe, when the pulse get material surface it will be reflected by the receiver inside the instrument, and the distance signal is transformed into level signal.

APPLICATION

Guided wave radar level meter used in water tank, acid and alkali storage tank, the slurry storage tank, solid particles and small oil tanks.

All kinds of conductive, non conductive medium, and corrosive medium.Such as coal, ash storehouse, oil tank, acid tank, etc.

TECHINICAL PARAMETER

DRUL-971 Cable Type

Application

 liquid, powder, solid particle

Measurement range

 30m

Process Connection

 thread, flange

Medium Temperature

 -40...250

Process Pressure

 -1.0...20bar

Accuracy

 ±10mm

Frequency Range

 100MHz...1.8GHZ

Explosion-proof/ Protection Degree

 ExiallCT6/IP67

Signal Output

 4...20mAHART(two-wire)

 

DRUL-972 Rod Type

Application

 liquid, powder, solid particle

Measurement range

 6m

Process Connection

 thread, flange

Medium Temperature

 -40...250

Process Pressure

 -1.0...20bar

Accuracy

 ±10mm

Frequency Range

 100MHz...1.8GHZ

Explosion-proof/ Protection Degree

 ExiallCT6/IP67

Signal Output

 4...20mAHART(two-wire)

 

DRUL-973 Coaxial Rod Type

Application

 liquid, powder, solid particle

Measurement range

 6m

Process Connection

 whorl, flange

Medium Temperature

 -40...250

Process Pressure

 -1.0...20bar

Accuracy

 ±10mm

Frequency Range

 100MHz...1.8GHZ

Explosion-proof/ Protection Degree

 ExiallCT6/IP67

Signal Output

 4...20mAHART(two-wire)

 

Installation Method

Reasonable installation can ensure the instrument long-time use and accurate measure.

 The instrument can adopt tread connection. Thread length can’t exceed 150mm. It can also be installed on the short pipe. If the diameter of the short pipe is from 2″to 6″, the height of the short pipe should ≤150mm. If it is installed on a longer short pipe, the cable probe should be fixed on the bottom in order to avoid the contact with the end of the short pipe.

 

The installation of DN200 or DN250 in a short pipe

When the instrument is installed in a short pipe which diameter is longer than 200mm, the inside wall of the short pipe will generate an echo. Measurement errors will be caused when the dielectric constant is low. Therefore,for diameter 200mm or 25mm short pipe , a special flange with ‘horn interface’ needs to be chosen.

 

• Installation on the plastic tank

Attention.

If you want the instrument operates normally, the surface of the process connection must be metal. When the instrument is installed on the plastic tank, if the top of the tank is also plastic or other non-conductive material, the instrument must match metal flanges. If you adopt thread connection, a metal plate should be equipped.

 

• The distance between the instrument probe and the tank wall

The distance from the instrument probe to the tank wall is recommended to be 1/6-1/4 of the tank diameter.(Longer than 300mm at least. For the concrete tank, 400mm at least.) When you choose the length of the probe, pay attention that the distance from the bottom of the probe to the tank bottom is longer than 30mm.

 

Notes:

• The radar installation can’t be installed to the spout below

• Avoid other devices in the tank contacting with the microwave conductive part.

• Avoid the guided wave cable probe contacting the installation short pipe.

 

The downward pull that the cable suffers

When you feed and out-feed, the medium will produce downward pull to the cable probe. The strength of it depends on the following factors:

1.the length of the cable

2.the density of the material

3.the diameter of the silo

4.the diameter of the cable

The following is the pressure produced by a 6mm cable probe in typical medium.

 

 The optimization of the interference

The inhibition of the interference echo:

The software can realize the inhibition of the interference echo. Then achieve the ideal measurement.

• Bypass pipe and guide wave pipe(It applies to liquid only.) For the medium whose viscosity ≤500cst, can use bypass pipe, waveguide or coaxial rod radar can be used to avoid the interference.

 

Measurement of corrosive medium

• When you measure the corrosive medium, you can choose the rod probe with plastic or tetrafluoroethylene pipe

 

The fix of the end of the guided wave radar probe

• There are 2 ways to fix the end of the probe. One is insulation fix and the other is non-insulation fix.

• Insulation fix: When the dielectric constant is low and the probe is fixed on the bottom of the metal tank, the insulation fix is needed.

• Non-insulation fix: When the dielectric constant is high and the tank is made of metal, other material with low dielectric constant or the similar dielectric constant to the medium, the non-insulation fix is chosen.

• Remark: When the user doesn’t know it is insulation or non-insulation, please contact with our company

The relationship between different kinds of medium and the measurement distance is listed in the following diagram.

Medium

 group

DK(s)

Solid particle

Liquid

Measurement range

1

1.4 …1.6

 

-condensensing gas, 

for example,N2C02

3m (Only refers to 

the coaxial rod probe.)

2

1.6-1.9

-Plastic with particles

-Liquefied petroleum gas, 

such as propane 

25m

- lime stone, 

special cement

-solvent

- sugar

- Freon 12 / Leone 

 

-Palm oil

3

1.9…2.5

-ordinarycement, 

plaster

-mineral oil, fuel

30m

4

2.5 …4

- Grains, seeds

-Benzene, styrene, tolunene,

30m

- Stone

- furan

- Grit

- naphthalene

5

4...7

-wetstone, ore

-Chlorobenzene, chloroform

30m

-salt

-cellulosespray

 

Isocyanuric hydrochloride , the amine

6

>7

- Metal powders

-aqueous liquids-alcohol

30m

- Carbon black

-liquid ammonia

- Coal

 

company 

  Yantai dongrun Instrument Co., Ltd. founded in 1998. It specializes in manufacturing online water quality analyzer, level meters, pressure gauge, flow meter, special temperature gauge and laboratory water analyzer.. Our company cooperates with Chinese Academy of Sciences and builds up a water analysis laboratory, mainly producing TOC analyzer, ammonia analyzer, fluorescence oxygen analyzer, etc. We have passed the ISO9001 certification. Our professional R & D team can provide technical supports to satisfy customer demand and our unique technologies can meet different working conditions.

 We are the important supplier of Yantai Wanhua Group,Pepsi,Sinopec,Jereil etc.

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher