Product Parameter | ||
Product Name | Ultrasonic Flowmeter | |
Flow rate range | 0-±10/S, forward and reverse measurement | |
Measurement accuracy | ±1% | |
Pipe diameter | DN15-DN6000 | |
Fluid temperature | -30°C-160°C | |
Fluid types | water, sea water, sewage, acid and alkali, alcohol, beer, various oils, etc., a single uniform liquid that can conduct ultrasonic waves | |
Pipe material | steel, stainless steel, cast iron, copper, PVC, aluminum, glass fiber reinforced plastic and other dense pipes, lining allowed | |
Communication interface | isolated RS485 serial interface, support MODBUS protocol | |
Data storage | SD card regularly stores the measurement results of the set parameter meter (optional) | |
Power supply mode | DC8-36V or AC85-264V | |
Signal output | 1 channel 4-20mA current output, impedance 0-1K, accuracy 0.1% 1 channel OCT pulse output, pulse width 6-1000ms 1 relay output (optional) | |
Signal input | 3 channels of 4-20mA current input (optional) Connect three-wire PT100 platinum resistance to realize heat measurement |