Enquiries
Message
Home > Products > Other
DC 30A 50A 50mV 75mV Electric current Shunt Resistors for Amp Panel Meter Monitor
  • DC 30A 50A 50mV 75mV Electric current Shunt Resistors for Amp Panel Meter Monitor

DC 30A 50A 50mV 75mV Electric current Shunt Resistors for Amp Panel Meter Monitor

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Model Number:
FL-2 50A
Type:
Fixed Resistor
Place of Origin:
Zhejiang, China
Brand Name:
NQQK
Rated Power:
10~50W
Resistance:
0.01 -100K
Technology:
Metal Alloy
Package Type:
Surface Mount
Resistance Tolerance:
1% 2% 5% 10%
Temperature Coefficient:
100ppm
Operating Temperature:
-40°C ~+60°C
Name:
50A 50mV Shunt
Color:
Black
Certificates:
CE
Shipping Method:
DHL & OTHER
Pack:
carton
Material:
Copper with nickel plated
Accuracy class:
0.5
Voltage drop:
50mv/75mv/100mv
Resistor:
10 Ohm 100 Watt Resistor
web:
www.nqqkelc.com
Supply Ability
Supply Ability:
1000000 Piece/Pieces per Month 50A 50mV Shunt
Packaging & Delivery

DC 30A - 50A Electric current Shunt Resistors for Amp Panel Meter Currect Monitorct Monitor

Product Description

--------- Product Details ---------
Welcome to NQQK, Welcome to contact us

There are too many models of the shunt, please consult before place order. thank you.

The catalouge will be sent you check.

 

The main technical parameters:
1, accuracy level: 2 ~ 4000A; 0.5: 5000 ~ 10000A; 1 level.
2, the ambient conditions: -40 ~ +60 ℃, relative humidity ≤ 95% (35 ℃).
3, overload performance: rated current 120%, 2 hours.
4, the voltage drop: 50mV60mV70mV100mV
5, the load under the heat: temperature stability tends to change, the rated current 50A the following does not exceed 80 ℃; rated current 50A or more does not exceed 120 ℃.

 

Precautions:
(Or copper) and the shunt connection is not allowed to have artificial contact resistance, the sampling point of the secondary voltage can not be sampled from the non-sampling point.

Actual use of the current (long) is recommended not to exceed 80% of rated current.

 

 

ColorBlack and Silver
Current rating10A-3000A
Voltage drop50mV,60mV,75mV,100mV
Accuracy class0.5/0.2
MaterialCopper with nickel plated
Overload capacity120% of rated current for 2hr
Functionare used to multiply the measuring range of current of measuring instruments.
ApplicationUse for DC digital Amp Meter.

 

 

 

1. Select the shunt method
(1) according to the ammeter (or dual-use current and voltage meter) marked on the dial mV selected shunt rated voltage drop specifications (commonly used is 75mV or 45mV). If the current meter does not have this value, use the following formula to calculate the voltage limit for the meter, and then select the shunt rated voltage drop specification.
Table voltage limit (mV) = ammeter full scale current (A) × ammeter internal resistance (Ω) ÷ 1000
(2) according to want to expand the current range to select the shunt rated current specifications.
(3) will be selected shunt two current terminals are connected with the power supply and load, the potential end of the ammeter, the ammeter should be noted that the polarity of the terminal to be connected to the ammeter on the range expanded to the shunt calibration current value.
2. A Method of Calculating Ammeter of Current Meter after Using
For motor test measurements, often an ammeter to configure multiple shunts to address the larger measurement range can guarantee the accuracy of the required measurement problems. All of the shunts used are required to have a nominal voltage drop equal to the ammeter, eg 75 mV. In this way, after the shunt is selected, the full scale of the ammeter is the rated current value of the selected shunt, and the multiple of the ammeter (that is, the current value of each scale of the dial) is the rated current of the shunt divided by the total number of scales of the dial.
The shunt used for DC current measurement is available in slot and non-socket versions. The shunt has a manganese nickel-copper alloy resistive bar and copper strip and is plated with a nickel layer. The rated voltage drop is 60mV, but can also be used as 75,100,120,150 and 300 mV.
Slot-type shunt rated current has the following: 5 A, 10 A, 15 A, 20 A and 25 A
The non-slot type shunt has a nominal current of 30 A to 15 kA standard spacing.

 

Shunt is actually a very small resistance of the resistance, when a DC current through, the pressure drop for DC ammeter display
DC ammeter is actually a voltmeter, full-scale value of 75mV
DC ammeter and shunt is supporting the use of;
For example: 100A ammeter supporting shunt resistance of 0.00075 Europe
Namely 100A * 0.00075 Europe = 75mV;
50A ammeter supporting the shunt resistance of 0.0015 Europe
50A * 0.0015 ohms = 75 mV.

 

 

 

FL-21, FL-19, FL-13, FL-21, FL-13, FL-21, FL-
FL-29 type, FL-39 type, Taiwan type, Russian type, Korean type, American type and so on. . .
There are many shunts, but the shape can be customized according to customer requirements. The enclosed shunt is much smaller in shape than an external shunt.

 

A shunt, also known as a synchronous motor, is required to proportionally supply fuel to multiple branches. Common for the flow of oil. Used to solve the cylinder synchronization, walking motor synchronization, oil lubrication. According to the material can be divided into aluminum and cast iron; according to the structure can be divided into gear and plunger;

 

FAQ

Q:How to order our product ? 

A:1).Please tell us the model and quantity and other request you need. 

   2).We make the PI for you.

   3).After you confirm the PI, we arrange the order for you after receiving your payment.

   4).After the goods finished, we send the goods out to you and tell you the tracking number.

   5).We will track your goods until you receive the goods. 

Q:  What's your warranty ?

A: 1-2 years

Q: What's your contact information:

A: Our address: Liushi town, Zhejiang province, China. 

Q: What's your shipment method?

A: We ship by Express, by air, by sea, by train. Normally we checked and compare, then provide

customer the most proper shipment method.

Q: What's about MOQ?

A: First order MOQ=1pcs

Q: If i want to release order, what's the payment method you accept ?

A: We accept T/T, Paypal, Western union, L/C,etc.

Q: If i want to release order, what's the process?

A: Thanks. You can send inquiry to us by alibaba, or send us by email, we will reply within 24hrs.

Company Information

 

 

 

 

  

Contact us

 

ADD:NO.18 QunYing Road, Xingguang Industrial Zone, liushi, Yueqing City, Zhejiang, China

Tel: +86 577 61787391               Fax:+86 577 61787392

Skype: NQQK ELC

Mobile/WeChat/WhatsApp:+86-139 6878 5810

Web:www.nqqkelc.com               E-mail:sales at nqqkelc.com

 

Thank you & Now send your kindly inquiry below, please!        

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher