Enquiries
Message
Home > Products > Other
Concrete Permeability Apparatus with 1 Cell, 3 Cell Model
  • Concrete Permeability Apparatus with 1 Cell, 3 Cell Model

Concrete Permeability Apparatus with 1 Cell, 3 Cell Model

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin:
Hebei, China
Brand Name:
RUSHI
Model Number:
RS-3085
Power:
380v-50HZ
Product name:
Concrete Permeability Apparatus
Working pressure:
20Kg/cm2
Number of specimen:
1pcs or 3PCS
Geometry of the molding:
dia.150*150mm
Dimensions:
500X650X1650mm
Weight:
135Kg
Supply Ability
Supply Ability:
100 Piece/Pieces per Day
Packaging & Delivery

 Concrete Permeability Apparatus - Single Cell

 

Product Description

 

The design of concrete mix aims at maximum durability for the conditions prevailing at the site where it is to be used. ability to resist the flow of water through, is one of the important durability characteristics. The permeability is determined on cement. mortar and concrete specimens, either cast in the laboratory or obtained by cutting out cores from existing structures. The Permeability test is carried out as per the standard IS:3085 and US Bureau of Reclamation.
One of the durability tests of concrete is to determine permeability of water through specimen. Permeability apparatus is used for determining the permeability of cement mortar and concrete specimens of 15cm cylinder cast in the laboratory
Salient Features
Specification: The concrete permeability apparatus comprises of a brass/ gunmetal cell of circle cross section mounted on a stand and a pressure chamber is connected to the cell through copper tubing and T-connector mounted on the stand with sleeve packed valve and rubber hose pipe with end connections. The cell assembly consists of one base plate, one metal funnel and one top plate, and a pressure tube is supplied to develop pressure in the chamber. The apparatus is supplied with a measuring cylinder 500cc to measure percolated quantity of water. Pressure can also be applied by a pressure air line or by a compressor.
Available for sample of size 150mm dia X 150mm high.
Available for sample of size 100mm dia X 100mm high.
Models available:
Concrete Permeability Apparatus 3 cell model for 100mm cylinder

Concrete Permeability Apparatus 1 cell model for 100mm cylinder
Concrete Permeability Apparatus 1 cell model for 150 mm cylinder
Concrete Permeability Apparatus 1 cell model for 300 mm cylinder
Note: Self purchase accessories(Compresssor with pressure gauge 0-20 kg/cm sq. with automatic pressure valve and pressure rubber hose)
is:3085-1965 Indian Standard
METHOD OF TEST FOR PERMEABILITY OF CEMENT MORTAR
AND CONCRETE
1. SCOPE
1.1 This standard covers the method for determining the permeability ofcement mortar and concrete specimens either cast in the laboratoryobtained by cutting out cores from existing structures.
2. PRINCIPLE
2.1 The test consists in subjecting the mortar or concrete specimen of known dimensions, contained in a specially designed cell, to a known hydrostatic pressure from one side, measuring the quantity of water percolating through it during a given interval of time and computing the coefficient of permeability as described in 8.1. The test permits measure- ment of the water entering specimen as well as that leaving it.
3.APPARATUS
3.1 Permeability Cell-The permeability cell shall consist of a metal cylinder with a ledge at the bottom for retaining the specimen, a flange at the top, a removable cover plate and a sheet metal funnel which can be securely bolted to the cell. Gunmetal, aluminium or other suitable corrosion-resistant metal shall be used for fabrication of the cell and cover plate, which shall be designed to safely withstand the maximum test pressure. A rubber or neoprene O-ring or other suitable gasket, seated in matching grooves, shall be used between the cell and the cover plate to render the joint water-tight. Typical details of the permeability cell together with pertinent dimensions for use with test specimens of various sizes, are shown in Fig. 1.
3.2 Water Reservoir-A suitable reservoir may consist of a length of metal pipe, 50 to 100 mm in diameter and about 500 mm long. The reservoir shall be fitted with a graduated side arm gauge-glass, and the necessary fittings and valves for admitting water and compressed air and for draining, bleeding and connection to the permeability cell,as shown in Fig.2.

- The choice of reservoir dimensions is necessarily a matter of compro- mise between the accuracy with which the water entering the specimen can be measured and the of the eapaoity. The combination would be the smallest diameter and sufficient length to provide a for at 24 houra of continuous operation. Lengths much greater than about 500 mm may be difficult to handle.
3.3 Pressure Lines-Heavy duty armoured rubber hose or suitable metal tubing or any other equally suitable hose or pipe shall be used for the various high pressure connections. All joints shall be properly made to render them leakproof.
4. ACCESSORIES

4.1 Supply of Compressed Air-Suitable arrangements shall be made for supplying compressed air at 5 kg/cm2 to 15 kg/cm2 see 6) to the permeability cell assemblies. Compressed air or nitrogen cylinders or alternatively a compressor of adequate capacity may be used. Suitable regulating valves and pressure gauges shall be provided. Several cells at different operating pressures may be served by a common source as shown in Fig.2.
4.2 Supply of De-aired Water-An adcquate supply of clean de-aired water shall be available for use in the permeability tests. Water may be easily de-aired for this purpose by boiling and cooling. De-aired water may be stored in closed containers, which should, as far as possible,be kept full. Unnecessary agitations and contact with air shall be avoided.

5. TEST SPECIMENS
5.1 Size of Specimens-The specimens shall be cylindrical in shape with height equal to the diameter. The standard size of specimen shall have diameter and height of 150 mm. In the case of specimens containing aggregates whose nominal size does not exceed 20 mm, the(and the height of the specimen may be reduced to 100 mm. In the case of specimens containing aggregates whose nominal size exceeds 40 mm,the diameter and the height of the specimen should not be less than about four times the nominal size of the aggregate.
5.2 Casting and Curing-The mortar or concrete mix shall be cast in split moulds of the required size, with a removable collar of about half the height set on the top. The material shall be compacted either by hand rodding or vibration, as proposed to be done during construction. The collar shall then be removed and the mould shall be struck off level with a straight-edge using a sawing motion without further trovelling or finishing, which might raise the fines to the surface.The specimen shallbe cured for 28 days unless otherwise specified by the engineer-in-charge.
6. PRESSURE HEAD
6.1 The standard test pressure head to be applied to the water in the reservoir should be 10 kg/cm2. This may, however, be reduced up to 5 kg/cm2in the case of relatively more permeable specimens where steady state of flow is obtaincd in a rcasonable timc, and may bc incrcased up to 15 kg/cm2 for relatively less permeable specimens and where sealing could be ensured to be fully effective.
7.PROCEDURE

7.1 Calibrating the Reservoir-Each reservoir shall be calibrated under the operating pressures of 5 kg/cm2 to 15 kg/cm2 (see 6) as indicated below:

With the reservoir drain-cock and the shut-off valve betweenthe reservoir and the cell closed, and with the air bleeder valve open, the reservoir shall be filled with water. The reservoir drain-cock shall then be opened to flush out any air and closed again. The reservoir shall be refilled to a point above the zero mark of the gauge-glass scale; the bleeder valve shall be closed and the desired air pressure applied. The drain-cock shall be carefully opened to bring the water to the mark and quickly closed.Water shall then be drawn off and caught in 250 ml increments in a graduated jar and the level in the gauge-glass read on the scale. The calibration constant for the reservoir shall be expressed in millilitres per division of the scale.
7.2 Preparing the Specimen-The specimen shall be thoroughly cleaned with a wire brush to remove all laitancc. The end faccs shall then be sand-blasted or lightly chiselled.
7.3 Sealing the Specimen-The specimen shall be surface-dried and the dimensions measured to the 0-5 mm. It shall then be centred in the cell, with the lower end resting on the ledge. The annular space between the specimen and the cell shall be tightly caulked to a depth of about 10 mm using a cotton or hemp cord soaked in a suitable molten sealing compound. The rest of the space shall be carefully filled with the molten sealing compound, level with the top of the specimen. Any drop in the duc to cooling shall be madc up, using a hcated rod to remclt the solidified compound before pouring fresh material over it. A mix- ture of bees-wax and rosin, applied smoking hot, forms an effective seal. The proper proportions are best chosen by trial. Other suitable materials are stearine pitch, marine glue, and various asphaltic compounds.
7.4Testing the Seal-It is essential that the seal is'watertight.This may be checked very conveniently by bolting on the top cover plate, inverting the cell and applying an air pressure of 1 to 2 kg/cm2 from below. A little water poured on the exposed face of the specimen is used to detect any leaks through the seal, which would show up as bubbles along the ledge. In case of leaks the specimen shall be taken out and resealed.
7.6 Running the Test-With the system completely filled with water,the desired test pressure (see 6) shall be applied to the water reservoir and the initial reading of the gauge-glass recorded. At the same time a clean collection bottle shall be weighed and placed in position to collect the water percolating through the specimen. The quantity of percolate and the gauge-glass readings shall be recorded at periodic intervals. In the beginning, the rate of water intake is larger than the rate of outflow. As the steady state of flow is approached, the two rates tend to become equal and the outflow reaches a maximum and stabilizes. With further passage of time, both the inflow and outflow generally register a gradual drop. Permeability test shall be continued for about 100 hours after the steady state of flow has been reached and the outflow shall be considered as average of all the outflows measured during this period of 100 hours.

NoTE-The stendy state of flow is defined as the stage at which tho outflow and inflow of water become equal for first time.
7.7 Test Temperature-The test shall preferably be carried out at a temperature of 27 2C. In case arrangements are not available for maintaining the above temperature, a record shall be maintained of the actual temperature. An approximate correction may made on the basis that each increase of temperature above the standard tempera- ture, results in 10 percent increase in the coefficient of permeability and vice versa.
7.8 Precautions-There are several precautions which shall be observed, before any dependable estimate of permeability can be obtained fromthe test data, of these the most important are as follows:
a)The seal around the specimen shall be effective. Leakage through it can give rise to entirely misleading results. Obtaining a good seal is a matter of experience only a general guidance can be provided.
b)It is important that the air content of the water entering the specimen should not exceed about percent. Excessive amounts of dissolved air can result in air locks in the specimen and appa- rent reduction in permeability. Periodical samples shall be from the cell drain-cock and the dissolved air determined.The system shall be drained and replenished with fresh de-aired water, as soon as the air content exceeds the above limit.
c)The flow should be permitted to attain the steady state before the coefficient of permeability is calculated. Examination of the inflow outflow rate data or suitable graphs of the same may be used to determine the establishment of the steady state.
d)The observation of outflow from the specimen is liable to be influenced by evaporation of the percolate during collection. The collection bottle may be housed in a humid chamber, or alter- natively, blank observations on a similar bottle containing water should be made and the necessary correction for evaporation loss applied. The inflow measurement provides an additional check.
e)It is very important that the specimen surface is carefully prepared by sand blasting or chiselling, as even a thin highly impervious skin can result in considerable underestimation of the permeability.
8.CALCULATION
8.1 The coefficient of permeability shall be calculated as follows:

K=Q/{AT*(H/L)}
where

K= coefficient of permeability in cm/sec;
Q= quantity of water in millilitres percolating over the entire period of test after the steady state has been reached;

A= area of the specimen face in cm2;
T=time in seconds over is measured;and
H/L=ratio of the pressure head to thickness of specimen,both expressed in the same units.
9.REPORT
9.1 The following information shall be included in the report on each specimen:
a)Identification mark of the specimen,
b)Particulars of mix,
c) Age at commencement of the test,
d)Duration of test,
e)Size of specimen,
f)Test pressure,
g)Test temperature,
h) Coefficient of permeability at test temperature,and
j)Corrected coefficient of permeability at standard temperature.

Product Image
 

 

 

Our Services

 

1. Installation and training:
a. If buyers visit our factory and check the machine, we will teach you how to installand use the machine, and also train your workers/technician face to face.
b.Without visiting, we will send you user manual and video to teach you to install and operate.
c.If buyer needs our technician to go to your local factory, please arrange board and lodging and other necessary things.
d.We will give your professional guidance (Product introduction and operation manual) together with product .

2. After Service:
a.One year guarantee for whole machine.
b.24 hours technical support by email 
c.If there is any problem found of the machine, we will repair it for free in one year.
d.Honesty to working for you, after or before sale with our patient and sincerit

FAQ

 

 

Frequently Asked Question:


Q1.Are you trade company or factory?
A:We are trade company but we also have own factories. Building trade company is just for exporting various types of concrete mould and others products.


Q2. How to visit your company
1. Fly to Beijing airport: By high speed train from Beijing Nan to Cangzhou Xi (1 hour),then we can pick up you.
2. Fly to ShangHai Airport: By high speed train from Shanghai Hongqiao to Cangzhou Xi(4.5 hours), then we can pick you up.

Q3:After an order is placed, when to deliver?
A:Generally about 7-20days, If we have inventory, we can arrange shipment within 3 days.
Please be aware that our production lead times depend on specific items and item quantities.

Q4:What about the warranty with after - sales services?
A:, We can help you repair your equipment freely.,even it's not from our factory. After the warranty, the professional after-sale service team will provide perfect technical support and help guests solve problems encountered while using our product, handles guest problems and complaints in a professional and timely.

Q5:What about the product' services and quality?
A:Each instruments must be carried out 100% quality examination and test when shipping and delivery goods. Product use training, each of our product provide video training to show you how to install & operate. We can arrange engineer to train the operation of equipment to customer's company when you need. Products are widely recognized and trusted by users.

Our Company

 

 Our company can also produce the customized testing machines as clients' requirements.
Best service and the best price for you.

Concrete Permeability Apparatus with 1 Cell, 3 Cell Model from China supplier
Concrete Permeability Apparatus with 1 Cell, 3 Cell Model from China supplier
Concrete Permeability Apparatus with 1 Cell, 3 Cell Model from China supplier
Concrete Permeability Apparatus with 1 Cell, 3 Cell Model from China supplier
Concrete Permeability Apparatus with 1 Cell, 3 Cell Model from China supplier
No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher