Model | ODD1200 | ||||||
Drying room air temperature (return air) | Medium normal temp. (25℃~63℃) | ||||||
Standard dehumidification (Return air) | 27℃ , 65%R.H | 20kg/h | |||||
35℃ , 60%R.H | 26.5kg/h | ||||||
50℃ , 50%R.H | 34.5kg/h | ||||||
60℃ , 45%R.H | 41kg/h | ||||||
Dehumidification (Return air) | 35℃ , 80%R.H | 41kg/h | |||||
50℃ , 80%R.H | 52kg/h | ||||||
Dehumidification (including moisture discharg) | 35℃ , 60%R.H | 41kg/h | |||||
60℃ , 45%R.H | 52kg/h | ||||||
Standard Dehumidifying air volume | 3200m³/h | ||||||
Standard Circulating air volume | 40000-26400m³/h | ||||||
Refrigerant | R134a | ||||||
Standard compressor input power | 9KW | ||||||
Main fan power | 4.4KW | ||||||
Circulation fan power | 7#forward and reverse two-speed fan2.2KW/1.5KW | ||||||
External fan power | 1.05KW | ||||||
Standard total input power | 16.7KW | ||||||
Air cooling condensor (FL optional) | FL-08 | ||||||
Power supply | 380V/3H/50HZ | ||||||
Drying control mode | Fixed value, curve program | ||||||
Equipment function | Dehumidification, moisture discharge, warming, air cooling temp. dropping. ventilation and cooling | ||||||
Control system | Touch screen + Single chip control | ||||||
Auxiliary heater power | 15KW | ||||||
Dimensions(Tray) | 1000*800*60mm | ||||||
Quantity(Tray) | 112 | ||||||
Equipment weight | 3230KG | ||||||
Dimensions(Equipment) | 6000*2400*2500mm |