Kingflex centrifugal glass wool insulation is a product made in a process in which glass fiber is made from molten glass using the patented centrifugal method and processed with addition of environmental adhesive mainly imposed of thermosetting resin.
Technical Data for glass wool insulation blanket | |||
Item | Unit | Index | Standard |
Density | kg/m3 | 10-48 | GB/T 5480.3 |
Average fiber dia | μm | 43959 | GB/T 5480.4 |
Water content | % | ≤1 | GB/T 16400-2003 |
Grade of combustibility | Non-combustible GradeA | GB 8624-1997 | |
Reshrinking temp | ℃ | 250-400 | GB/T 11835-2007 |
Thermal conductibility | w/m·k | 0.034-0.06 | GB/T 10294 |
Hydrophobicity | % | ≥98 | GB/T 10299 |
Moisture rate | % | ≤5 | GB/T 5480.7 |
Sound absorption coefficient | 1.03 product reverberation method 24kg/m3 2000HZ | GBJ47-83 | |
Slag inclusion content | % | ≤0.3 | GB/T 5480.5 |
Technical Data for glass wool insulation board | |||
Item | Unit | Index | Standard |
Density | kg/m3 | 24-100 | GB/T 5480.3-1985 |
Average fiber dia | um | 5.5 | GB/T 5480.4-1985 |
Water content | % | <1 | GB/T 3007-1982 |
Reaction of fireclassification | A1 | EN13501-1:2007 | |
Reshrinking temp | >260 | GB/T 11835-1998 | |
Thermal conductibility | w/m.k | 0.032-0.044 | EN13162:2001 |
Hydrophobicity | % | >98.2 | GB/T 10299-1988 |
Moisture rate | % | <5 | GB/T 16401-1986 |
Sound absorptioncoefficient | 1.03 product reverberation method 24kg/m3 2000HZ | GBJ 47-83 | |
Slag inclusioncontent | % | <0.3 | GB/T 5480.5 |
Specification and Dimension | ||||
Product | Length (mm) | Width (mm) | Thickness (mm) | Density (kg/m3) |
Glass wool Insulation blanket | 10000-20000 | 1200 | 30-150 | 12-48 |
Glass wool Insulation board | 1200-2400 | 600-1200 | 20-100 | 24-96 |
Application of glass wool insulation blanket:
Kingflex centrifugal glass wool insulation is the best material used for the insulation and sound absorption of steel structure, they widely apply for industrial plants, warehouses, public facilities, exhibition centers, shopping centers,cold stores and a variety of indoor playgrounds, sports grounds and other buildings.
Application of glass wool insulation board/panel:
• For thermal and acoustic insulation of concrete floors in order to reduce energy loses and transmission of impact sound.
• For insulation of single leaf walls with dressed stone or marble facings and cavity wall construction, precast structures and prefabricated buildings.
• For thermal insulation of concrete and metal roof decks.
• For thermal insulation of industrial applications; boilers, ovens, refrigerators, storage tanks, marine and road transport.
Advantages:
Sound-absorbing/Noise Reduction
Non- Toxic
Good Thermal Stability
Excellent Durable Resistance to Tide
Heat Preservation and Heat insulation
Non-combustible Grade A
Low Thermal Conductivity (0.034 W/mk)
Operating Temperature (-100°C to 450°C)
Excellent Corrosion and Moisture Resistance
Extremely Light Weight
Superior Acoustical Properties
Asbestos - Free
Perfect sound absorption performance.
Effectively eliminate and control of pipeline system noise;
High-density 64kg/m³ and thickness 50mm can reduce 20db noises.
High re-shrinking temperature(250~350 ℃ ).
Waterproof & anti-moisture.
Resistant to corrosion.
Low density.
Stable chemical property.
Easy to install.
Technical Data |
|||
Item |
Unit |
Index |
Standard |
Density |
kg/m3 |
10-48 |
GB/T 5480.3 |
Average fiber dia |
μm |
5-8 |
GB/T 5480.4 |
Water content |
% |
≤ 1 |
GB/T 16400-2003 |
Grade of combustibility |
|
Non-combustible GradeA |
GB 8624-1997 |
Reshrinking temp |
℃ |
250-400 |
GB/T 11835-2007 |
Thermal conductibility |
w/m·k |
0.034-0.06 |
GB/T 10294 |
Hydrophobicity |
% |
≥ 98 |
GB/T 10299 |
Moisture rate |
% |
≤ 5 |
GB/T 5480.7 |
Sepcification |
||||
Product |
Length(mm) |
Width(mm) |
Thickness(mm) |
Density(kg/m3) |
Glass Wool B lanket |
8000-25000 |
1130-1200 |
25-150 |
12,16,20,24,32,40,48 |
1.What is insulation product?
Insulation product is used to cover pipes, ducts, tanks, and equipment in commercial or industrial environments and is typically relied upon to control temperature for a much broader range of temperature variances that of a typical home. Home or residential insulation is typically found in the exterior walls and attics and is used to keep the home environment a consistent, comfortable living temperature. The temperature differential in a home insulation environment is in most cases far less than that of a typical commercial or industrial application.
2.What about the lead time?
The bulk goods order production delivery time will be within three weeks after receiving the down payment.
3.How are your products tested?
We normally test BS476, DIN5510, CE, REACH, ROHS, UL94 at an independent lab. If you have a specific request or a specific test request please contact our technical manager.
4.What type of your company?
We are an enterprise integrating manufacture industry and trade.
5. What is your main product?
NBR/PVC rubber foam insulation
Glass Wool Insulation
Insulation Accessories