Description:
1: Channel number: SK32-32 have 32 channels.
2: SIM slots: SK32-32 device can read 32 SIMs in total. That means the device can support 32 SIMs working at one time (32 channels), and each channel can read 1 SIMs named A,B,C,D . (This SIMs will rotate to avoid blocking).
3: Channel LED: One channel include 4 LEDs for ABCD SIMs.
ACT |
LED Status |
||
Startup(Rebooting) |
All ON |
||
Fail mobile connection |
Blink |
Flash(100ms) |
SIM is locked by device or operator |
Flash(500ms) |
SIM is No Balance |
||
Flash(1000ms) |
SIM registered failed |
||
Calling |
ON |
||
Idle or No SIM |
OFF |
4: Power LED.
5: RESET: Restore the factory default (Press the button and hold on for more than 5s).
6: Power Interface (Input power: 100-240V ~ 50-60Hz 1.2A MAX Output power: 12V/5A).
7: LAN: Ethernet port (100M/10M Adaptive).
8: WAN: Ethernet port (100M/10M Adaptive The default WAN IP is 192.168.1.10).
9: CONSOLE Interface: USB serial port (Baud rate: 115200, 8.n.1.n).
10: Antenna connector.
11: Cooling fans: Support 2 mode – ON & Automatic (When Control center detect the CPU too hot, fans will be ON, otherwise it will OFF).
1.4 Special Features
Support HTTP/SIP SMS API
Support USSD/AT API
Support IMEI modification
Support SMPP server/client
Support SNMP
1.5 Mobile Features
SMS Send, Receive and Forward(GSM/SIP/HTTP)
SMS Inbox
AT Command, USSD
SMS Format: PDU/TXT
PIN Code Management
CDMA Delay Answer
GSM Polarity Reversal
Carrier Selection
2 Quick Start
2.1 Insert SIM Cards
A/C: The chip side towards up.
B/D: The chip side towards down.
The external antenna should be installed vertically always on a site with a good wireless signal. It is strongly recommend that you choose the long antenna.
2.3 Connect Device
Connect the power adapter to keep power on, connect a RJ45 network cable from GoIP WAN port to a router LAN port (The router should be connected to internet).
router: A device used for visiting internet, such as TP-Link, Tenda, D-Link.
2.4 Serial Connection
Connect one side of serial cable to the console port on the back panel, another side to computer USB port. (Don't need connect it normally)
2.5 Check Device IP
The GoIP WAN default IP is 192.168.1.10.
1 If the router LAN IP is 192.168.1.1, the GoIP default IP will be OK.
2 If the router LAN IP is not 192.168.1.1, for example 192.168.0.1, the GoIP default IP should be corrected.
2.6 Log Into The Management Web
After retrieving the IP address, open browser (IE, Chrome, FireFox, Opera …), input the IP address and the login web will return. The username & password will be needed to log into.
Default account is root
Default password is root.
When login successfully, the “Initial Setting” guide page will be help to make gateway working more easily.
3 Gateway Setting
3.1 Network Setting
Items |
Description |
|
WAN Type |
Dynamic IP |
Automatically get IP from local network. |
Static IP |
Manually set up gateway IP 1, The WAN IP should be in the segment of the router. 2, The WAN IP should be unique or it will conflict with other network devices. 3, Check the IP Mask and Default Gateway in your router configuration. (The WAN IP segment will be same with the router which gateway connect to. For example, the router LAN IP is 192.168.10.1, and the gateway WAN IP should be 192.168.10.xxx.) |
|
PPPoE |
Need ISP (Internet Service Provider.) offer the account and password .Use this mode when there is no router in the local network |
|
WAN IP |
The WAN IP address of gateway |
|
IP Mask |
The subnet mask of gateway |
|
Default Gateway |
Default gateway IP address. Example: router IP. |
|
DNS Gateway |
Domain name server IP address. Example: 8.8.8.8. |
3.2 Port Setting
Basic Config
Hardware Properties
3.3 Base Station
Items |
Description |
Max Channels |
The maximum number of base station |
Lowest Valid Signal |
The lowest valid signal of base station, the default value is -90 dbm. SIM card will not register in the base station which signal is lower than the value. |
Switch Period |
Base station switch period, the default value is 60 minutes. Base station will switch automatically by the period (when base selection is “poll”). |
Base Balancing |
Disable: every channel will select the base station with best signal. We suggest this mode. Enable: every channel will try to select different base station. |
Base Stations settings/operations.
3.4 IMEI Setting
IMEI means International Mobile equipment Identity, it is a 15-digit number. The gateway can do IMEI modification, it can protect SIM from blocking. With the function, you can do static IMEI or dynamic IMEI.
You can click “Add New” button to add a new dynamic IMEI list, this list includes initial IMEI value of IMEI group and the size of IMEI group. Click “Delete” will delete a exist IMEI list, if you want to change the settings of dynamic IMEI list, please click “Edit” button.
IMEI Switchin
3.5 Rules Setting
Dialing Plan
The dial pattern string is a normal regular expression. For example: The pattern 90[1-4] means the dialed number start with 90 and end with anyone of 1/2/3/4. So like the input 901,902,903 or 904 all can be accepted.
Translated Prefix: Another number which GoIP rewrite the Original prefix to.
CallerId Hidden: Hide the SIMs number in GoIP when Callee’s phone receive the VOIP calls.it need the SIMs operator support this.
Black List
3.6 obile Setting
PIN Setting
When SIMs inside need PIN code to unlock, user can type those code in this ABCD option in advanced.
Billing Setting
Billing: Specify whether enable GoIP billing or not. If set to Enabled, system will bill the outbound calls for the port which has been assigned with billing tariffs.
Hangup The Call: Specify whether enable hangup the call when balance is ont enough. When select enable, the call will be hang up immediately when run out of balance. But when you select disable the call will not be hangup.
USSD Check: Specify whether enable to get balance through USSD check or not. This field takes effect only when GoIP Billing is set to Enabled.
Price and support
we are manufacturer and can give you factory price. we can give you professional free support services with the help of our technology support engineers.
Skype :live:61dc7ce87cbb984f
telephone:+8615079669301
wechat:390761884