China PMK high quality syrup mixing tank
Dear all, thank you for visiting our web. Hope you can find what you need here! For a more efficent communication, please refer to the following question when sending the inquiry.
1. What is your product? (shampoo, or sucscreen or ?)
2. What is the capacity you need?
3. Is your product highly corrosive?
4. Does the product needs heating when mixing?
Other Application of this syrup mixing tank
PMK syrup mixing tank |
||||||||||
|
Technical Parameter |
Payment terms |
Payment terms:T/T,Western Union,PayPal 30% deposit before production,70% balance before shipment Trade term:EXW,FOB&CIF are available |
Material |
Stainless steel 304/stainless steel 316 |
Packing Information |
Safe package: PE film+plywood case |
Safety Instruction of this syrup mixing tank:
1. Equipment must be reliable ground zero line.
2. Often use a millimeter to check the insulation factor of the device
3. On a regular basis (every month) to check electrical control box of electrical wire ear elastic
4. In the case of very wet, you should stop using the equipment as soon as possible to avoid short circuit
5. In the electric box around the control circuit should have good ventilation, to ensure the safety of the device
Common Faults and Solutions
1. Electric heating, turn on the heating button, heating button leakage protection circuit disconnect :
Cause:Heating tube burned;
Solution:replaced heating tube;
2. The heating tube no response:
Cause:Check the heating tube is short circuit, check button, GFCI is whether working;
Solution:Determined after the repair and replacement parts;
3. the circuit trip when Homogeneous opened:
Cause: (1) Homogeneous electrical short circuit.
(2) Homogeneous seal damaged, material or leakage of water from the homogenizer, the discovery of long-term use did not cause the motor burned out;
Solution: Check whether the motor short circuit, replace, repair motor, replace sealed homogeneous;
4. mixing paddle no working:
Cause:The drive has failed;
Solution: (1)Check whether there are procedures disorder inverter, inverter reset procedure;
(2) Frequency is faulty, timely maintenance;
(3) three-phase indicator does not light
Cause: (1)bad light (2)Circuit lack of phase;
Solution: (1)Replacement lamp
(2)Check the circuit components damaged, replace it in time
Maintenance Guidence:
1. Keep the equipment looks clean, no watermarks, smooth
2. Keep equipment clean, after finished product should be cleaned with hot water as soon as possible
3. Check on the homogeneous blade usually, Are there loose screws
4. Homogenizer into the water whether the flow, the water solenoid valve is working properly
5. Check the mixing gear regularly adequacy of the grease, any abnormal sound
Picture Show |
Picture of the touch screen
Picture of the mixing paddle
Picture of the lid
CE Certificate of this pressure homogenizer |
Picture of Package |
About Promake