Product Brand | AOASIS | Name | Conventional Circuit Breaker |
Product Type | AOW-1000 | Rated Current In(A) | 1000 |
Pole Number | 3/4 | Rated Voltage Ue(v) | 400/690 |
Insulation voltage Ui(V) | 1000 | Impulse Withstand Voltage Uimp (V) | 12KV |
Type | AOW-1000 | AOW-1600 | AOW-2500 | AOW-4000 | ||
Frame size rated current Inm (A) | 1000 | 1600 | 2500 | 4000 | ||
Pole | 3P,4P | 3P,4P | 3P,4P | 3P,4P | ||
Rated current In (A) | 1000 | 1600 | 2500 | 4000 | ||
Rated voltage Ue (V) | 400/690 | 400/690 | 400/690 | 400/690 | ||
Insulation voltage Ui (V) | 1000 | 1000 | 1000 | 1000 | ||
Impulse withstand voltage Uimp (V) | 12kV | 12kV | 12kV | 12kV | ||
Ultimate breaking capacity lcu (kA) | AC400V | 100 | 100 | 100 | 100 | |
AC690V | 65 | 65 | 65 | 65 | ||
Running breaking capacity lcs (kA) | AC400V | 65 | 65 | 65 | 80 | |
AC690V | 65 | 65 | 65 | 65 | ||
Short-time withstand current(1s)(RMS) lcw (kA) | AC400V | 65 | 65 | 65 | 80 | |
AC690V | 65 | 65 | 65 | 50 | ||
Connection mode | ||||||
Overall dim.(mm) H(height)*W(width)*L(thickness) | Fixed type 3P | |||||
Fixed type 4P | ||||||
Drawout type 3P | 334*206*244 | |||||
Drawout type 4P |
Type | AOW-2000 | AOW-3200 | AOW-6300 | ||||
Frame size rated current Inm (A) | 2000 | 3200 | 6300 | ||||
Pole | 3P,4P | 3P,4P | 3P,4P | 3P | |||
Rated current In (A) | 400,630,800,1000,1250,1600,2000 | 2000,2500,2900,3200 | 4000,5000 | 6300 | |||
Rated voltage Ue (V) | 400/690 | 400/690 | 400/690 | 400/690 | |||
Insulation voltage Ui (V) | 1000 | 1000 | 1000 | 1000 | |||
Impulse withstand voltage Uimp (V) | 12000 | 12000 | 8000 | 8000 | |||
Power frequency withstand voltage U (V) | AC3500 50HZ | AC3500 50HZ | AC3500 50HZ | AC3500 50HZ | |||
Rated current of N-pole IN (A) | 50%ln | 50%ln | 50%ln,100%ln | 50%ln,100%ln | |||
Ultimate breaking capacity lcu (kA) | AC400V | 80 | 100 | 120 | 120 | ||
AC690V | 50 | 65 | 85 | 85 | |||
Running breaking capacity lcs (kA) | AC400V | 50 | 80 | 100 | 100 | ||
AC690V | 40 | 65 | 75 | 75 | |||
Short-current making capacity lcm (kA) | AC400V | 176 | 220 | 264 | 264 | ||
AC690V | 105 | 143 | 165 | 165 | |||
Short-time withstand current(1s)(RMS) lcw (kA) | AC400V | 50 | 80 | 100 | 100 | ||
AC690V | 40 | 50 | 75 | 75 | |||
Closing time (ms) | 70 (max) | 70 (max) | 70 (max) | 70 (max) | |||
Electrical life | AC400V | 6500 | 3000 | 500 | 500 | ||
AC690V | 3000 | 1500 | 500 | 500 | |||
Mechanical life | Maintenance free | 15000 | 10000 | 4000 | 4000 | ||
Maintenance required | 30000 | 20000 | 8000 | 8000 | |||
Connection mode | Horizontal, vertical | Horizontal, vertical | Horizontal | Horizontal | |||
Overall dim.(mm) H(height)*W(width)*L(thickness) | Fixed type 3P | 402*362*323 | 402*422*323 | ||||
Fixed type 4P | 402*457*323 | 402*537*323 | |||||
Drawout type 3P | 432*375*421 | 432*435*421 | 432*813*494 | 432*928*494 | |||
Drawout type 4P | 432*470*421 | 432*550*421 | 432*928*494 |