Functions Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP 1)ECG Heart rate(HR) ECG waveform Arrhythmia and ST-segment analysis 2)RESP Respiration rate(RR) Respiration waveform 3)SpO2 Oxygen saturation(SpO2) Plethysmogram(PLETH) waveform Pulse rate(PR) Bar graph 4)NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN) 5)TEMP T1, T2, TD 6)IBP(optional) CH1:SYS,DIA,MAP CH2:SYS,DIA,MAP IBP waveform 7)CO2(optional) EtCO2 InsCO2:Inspired Minimum CO2 AwRR:Air Way Respiration It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.
Features 1)12.1'' TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech). 2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection. 3)All-round monitor for adult, pediatric and neonate. 4)With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe. 5)Finish all operations by keys and knobs. 6)Maximum 8-channel waveform synchronous display. 7)Display 7-lead ECG waveform on one screen, cascade ECG waveform display 8)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling. 9)Heart rate variability (HRV) analysis function 10)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data. 11)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events. 12)Drug concentration calculation and titration table functions. 13)One-touch printing of trend graph 14)Connect to Central Monitoring System by 3G, Wi-Fi or wired mode. 15)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring. 16)Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary).
Performance
ECG Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, dual-channel 3-lead, single-channel Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s HR: Measurement and alarm range: 15~350 bpm Accuracy: ±1 % or ±1 bpm, whichever is greater Alarm accuracy: ± 2 bpm Resolution: 1 bpm ST-segment monitoring: Measurement and alarm range: -2.0 mV ~ +2.0 mV Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Pacemaker: yes