CNMC-E POLYURETHANE PU SPRAY FOAM MACHINE
Whether it is a home, school or business, a building should be strong and able to protect the people inside it from the elements. Closed-cell spray foam can improve a building’s strength and durability in several ways.
Spray Foam Roofs: Strong and Durable
Applying a spray polyurethane foam (SPF) roofing system can improve a building’s strength. In fact, SPF roofs have effective lifespans that can exceed 30 years.
Because SPF conforms and adheres to the surface on which it is sprayed, a strong bond forms to protect the roof. The layer of spray foam is seamless and self-flashing, which can eliminate the ability of water to seep through weak spots, such as fasteners and seams. Spray foam can be applied in a sloped manner to allow water to easily drain off the roof.
The bond that SPF forms to the roof can increase a building’s resistance to wind uplift. So during periods of high wind, a home or building with a spray foam roof generally experiences less damage than a building without SPF. A prominent spray foam consultant notes that he has found that “when added to the inside of a structure, spray foam ‘glues’ the whole building together, enhancing overall wind and pressurization resistance.
CNMC-E POLYURETHANE PU SPRAY FOAM MACHINE
Model |
CNMC-E |
Power source |
single phase 220V 50Hz |
Heating powe |
7.5KW |
Driven mode |
pneumatic |
Air source |
0.5~0.8 MPa ≥0.9m³/min |
Raw output |
2~12 kg/min |
Maximum output pressure |
11MPA |
AB material output ratio |
1:1 |
Spray gun |
1 Set |
Feeding pump |
2 sets |
Heating hose |
15meters |
Gun connection pipe |
2pieces |
Feed delivery pipe |
2pieces |
pneumatic pipe |
5meters |
Spare parts |
1set |
Packing size |
750mm X 560mm X 1130mm |
Machine weight |
109KG |
1:Spray gun
2:Transfer pump:stainless steel
3:Heating hose :External heating 15 meters one roll
4:Spare Parts tool box
CNMC-E POLYURETHANE PU SPRAY FOAM MACHINE
SPF offers the following benefits:
Non-Permeable Air Seal
SPF expands to fill all voids and gaps within the framing system, creating a three-in-one Insulation, Air Barrier, and Vapor Retarder system. Traditional insulation systems are subject to unwanted air infiltration, a phenomenon called wind wash. With wind wash, outside air and moisture can be introduced into the wall cavity, greatly diminishing the R-Value. SPF’s closed cell structure does not allow air or moisture to penetrate. SPF virtually eliminates the heat loss that is associated with wind washing.
SPF prevents airborne contaminates such as mold, spores, pollens, and dust from penetrating the building envelope.
High R-Value
With an aged R-Value at 6.2 per inch (Closed Cell) and 4.2 per inch (Open Cell) SPF is vastly superior to fiberglass. With the Closed Cell Foam, there are Millions of closed cell bubbles virtually eliminating heat loss through convective air currents within the wall cavity. There is no reduction in R-Value over time as there is with traditional insulation systems.
Quiet
An SPF home has a measurable reduction in outside noise such as traffic, airplanes and barking dogs.
Green
Qualifies for multiple credits in LEED, Energy Star, and other energy saving programs.
No CFCs, HCFCs, or other gasses harmful to the environment. No airborne glass fibers.
Economic
Spray Foam Insulation offers a lifetime of performance and savings to you, the home owner. A typical SPF home pays for the upgrade via energy savings in 3 to 5 years. After that, it is just money in your pocket.
CNMC-E POLYURETHANE PU SPRAY FOAM MACHINE
1. The cylinder solenoid valves are all imported, more expensive than the common cylinders.
2. Free on-line training for technology, full way tracking and testing, high sales volume.
3. All accessories are supplied by the original manufacturer and are available to customers at cost price
4. The high pressure pipe is anti-corrosion.
5. The temperature control meter is dual display, which can display the actual temperature and the set temperature. Other manufacturers can only display the set temperature and can not see the actual temperature. Red meter shows the actual temperature, green shows the set temperature
6. The operation temperature control panel is independent module which can be replaced separately. For other factories ,there is an integrated board next to the temperature control table,if one is broken ,others temerature meters all should be changed .
Learn to maintain machine :
Main Machine Daily Use and Maintenance:
1 Replace DOP in oil cup of primary-secondary pump daily;
2 When equipment stops running, swerve Start/Reset switch to reset direction, making sure cylinder rod fully soaked inside DOP liquid, in this way it can prolong service life of seal ring.
3 Check sensitivity of the equipment heating system, if anything goes wrong, please fix the problem as soon as possible.
4 When equipment isn’t working, please turn off heating system timely, for not only it prevents potential danger also avoids low foaming quality cuz polyol material long-time heating.
5 Make sure turning on and off heating system in correct order. When turning on, first start main power,then turn on heating system; when turning off, first stopping heating system then turning off main power.
6 Remember to check if there’s enough oil inside oil-water separator and the water expelled from the separator;
The Leader of the Belt and Road
|
Mrs.Cindy Liu |
|
cnmc005(at)chnmach.com |
||
Skype | liuguiyun1991 | |
Whats App |
+8615653795070 |
|
Telephone |
+8615653795070 |