LC1-D3210 30A telemecanique AC contactor
APPLICATION
-------------------------------------------------------------------------------------------------------------------------------------------
CJX2(LC1) series AC contactor (simplified as contactor in the following) is suitable for using in the circuits up to the rated voltage 660VAC 50Hz or 60Hz, rated current 95A, for making and breaking and frequent starting, controlling the AC motor. Combined with the auxiliary contact group, air delayer, machine interlocking device etc. It is conbined into the delay contactor, mechanical interlocking contactor, star-delta starter, with the thermal relay, it is combined into the electromagnetic starter.
TYPE AND MEANING
-------------------------------------------------------------------------------------------------------------------------------------------
Coil Voltage (V) | 24 | 36 | 48 | 110 | 127 | 220 | 230 | 240 | 380 | 415 | 440 | 480 | 600 | 660 |
50Hz | B5 | C5 | E5 | F5 | G5 | M5 | P5 | U5 | Q5 | N5 | R5 | T5 | S5 | Y5 |
60Hz | B6 | C6 | E6 | F6 | G6 | M7 | P6 | U6 | Q6 | N6 | R6 | T6 | S6 | Y6 |
50/60Hz | B7 | C7 | E7 | F7 | G7 | M7 | P7 | U7 | Q7 | N7 | R7 | T7 | S7 | Y7 |
SPECIFICATION
-------------------------------------------------------------------------------------------------------------------------------------------
Type | CJX2-09 | CJX2-12 | CJX2-18 | CJX2-25 | CJX2-32 | CJX2-40 | CJX2-50 | CJX2-63 | CJX2-80 | CJX2-95 |
Rated insulation voltage (V) | 660 | 660 | 660 | 660 | 660 | 660 | 660 | 660 | 660 | 660 |
Conventional thermal current (A) | 20 | 25 | 32 | 40 | 50 | 60 | 75 | 80 | 110 | 125 |
Rated operational current | 9 | 12 | 16 | 25 | 30 | 40 | 50 | 63 | 80 | 95 |
Controlled power (KW) 220V | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 25 |
Controlled power (KW) 380V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 |
Controlled power (KW) 415V | 4 | 5.5 | 9 | 11 | 15 | 22 | 25 | 37 | 45 | 45 |
Controlled power (KW) 440V | 4 | 5.5 | 9 | 11 | 15 | 22 | 30 | 37 | 45 | 45 |
Controlled power (KW) 660V | 5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | 45 | 45 |
Note | The installation of the relays can use two screws and also use the 35mm installation rail | The installation of the relays can use three screws and also use the 75mm or 35mm installation rail |
Note: 3P: three NO main contacts; NC: one NO auxiliary contacts; NC: one NC auxiliary contacts.
SPECIFICATION OF COIL
-------------------------------------------------------------------------------------------------------------------------------------------
Type | CJX2-09 | CJX2-12 | CJX2-18 | CJX2-25 | CJX2-32 | CJX2-40 | CJX2-50 | CJX2-63 | CJX2-80 | CJX2-95 | ||
Closing voltage 50/60Hz(V) | (0.85 ~1.1)Us | |||||||||||
Releasing voltage 50/60Hz(V) | (0.2~0.75)Us | |||||||||||
Coil Power | 50Hz | Closing | 70 | 70 | 110 | 110 | 110 | 200 | 200 | 200 | 200 | 200 |
Closed | 8 | 8 | 11 | 11 | 11 | 20 | 20 | 20 | 20 | 20 | ||
60Hz | Closing | 80 | 80 | 115 | 115 | 115 | 200 | 200 | 200 | 200 | 200 | |
Closed | 8 | 8 | 11 | 11 | 11 | 20 | 20 | 20 | 20 | 20 | ||
Consumption | 1.8~2.7 | 1.8~2.7 | 3~4 | 3~4 | 3~4 | 6~10 | 6~10 | 6~10 | 6~10 | 6~10 |
OUTLINE & MOUNTING SIZE
-------------------------------------------------------------------------------------------------------------------------------------------
Outline size
Mounting size
LC1-D3210 30A telemecanique AC contactor
Q: Are you the MANUFACTURER or Trader?
A: we are both the factory and trade company for switching power supply, as well as other products, the products are of high quality with most reasonable price.
Q: What is your MOQ?
A: the MOQ can be only 1pc, we suggest for wholesaler order for smaller order online, welcome to contact us for details.
Q: What is the LEAD TIME?
A: the lead time is usually 2-20 days, it depends on your exact product and quantity.
Q: Do you accept OEM?
A: Yes, it is highly welcome.
LC1-D3210 30A telemecanique AC contactor