Outside measurement | 650×410×450mm |
Voltage | 380V/220V/415 50Hz 60HZ |
Power | 3KW |
Maximum ID of cutting hose | 51mm |
Protection class | IP54 |
Dies | 10pieces |
Trouble phenomena | Trouble reason | Eliminating method |
Machine has not action | Oil tank has not been filled with oil | Fill oil as per requirement |
Motor rotation direction is not correct | Regulate two phase lines | |
Electric trouble | Overhaul electric circuits | |
Scale is damaged | The scale is fastened on the oil cylinder end face by the screw | Regulate the scale as per the instruction to make scale to telescope freely |
Conductor at scale location is connected with scale | Anew connect the scale conductor to make it to be insulated from scale base | |
Electric trouble | Overhaul electric circuits and electric elements | |
Scale conductor cutting | Anew connect scale | |
System pressure is excessively low | Adjust buckling pressure-regulating valve | |
No buckling | The valve core of solenoid reversal valve is seizured by foreign matters | Dismount solenoid reversal valve, use gasoline to clean the valve core. |
Electric trouble | Overhaul electric circuits | |
Mould is not opened | Opening mould pressure is excessively low | Adjust opening mould pressure regulating valve |
Electric trouble | Overhaul electric circuits | |
Lubrication is poor | Smear grease on the working inclined face of mould base | |
Oil leakage | Joint is not tightened closely | Tighten the oil pipe joint |
Sealing washer is damaged. | Replace sealing washer |