FEATURES:
The water tube type, burner on top design minimizes carryover and produces dry 99+% saturated steam in 5 minutes or less from a cold start. Faster start-up means less fuel used, greater savings, and more responsible use of precious natural resources.
Ultra Compact Design Saves Space and Costs
LSS boilers occupy 33% less floor space than LWS boilers, and do not require tube pull space. Compact design means much smaller radiation losses and larger fuel savings.
Full Steam Output Within Five Minutes
Floating headers mean fast start-up. T·SUN LSS boilers produce fast steam in 5 minutes or less from a cold start-up. LWS boilers require from 1 to 1.5 hour start-up times. T·SUN’s unique design yields significant time and fuel savings.
Dry Steam
The T·SUN LSS design minimizes carryover and produces dry 99+% saturated steam through a 3-stage process:
POPULAR ALL OVER THE WORLD:
Customers in China: DUPONT, VEOLIA, MILLIPORE, Panasonic, TCL, CGET, LONHON, SEA-LION, etc
Customers in 115 countries & regions:
Europe: U.K., Germany, Belgium, Holland, Sweden, Norway, Spain, Russia, Hungary, Romania, Bulgaria, Lithuania, Estonia, Slovenia, Slovakia, Ukraine, Georgia
America: U.S.A., Canada, Mexico, El Salvador, Costa Rica, Nicaragua, Jamaica, Colombia, Brazil, Argentina, Ecuador, Chile, Paraguay, Saint Lucia, Netherlands Antilles, Peru
Africa: South Africa, Egypt, Algeria, Niger, Nigeria, Senegal, D.R.Congo, Congo Brazzaville, Ghana, Tunisia, Botswana, Swaziland, Uganda, Zimbabwe, Sudan, Ethiopia, Zambia, Tanzania, Kenya, Angola, Gabon, Mozambique, Madagascar, Lesotho
Asia: China, Japan, Singapore, Malaysia, Philippines, Indonesia, Thailand, Myanmar, Vietnam, North Korea, South Korea, Mongolia, India, Sri Lanka, Maldives, Pakistan, Turkmenistan, Kyrgyzstan, Uzbekistan, Kazakhstan, U.A.E. , Saudi Arabia, Kuwait, Qatar, Iraq, Israel, Lebanon, Turkey, Jordan
Oceania: Australia, New Zealand, Papua New Guinea
FACTORY ASSURANCE:
SPECIFICATIONS:
Model Items |
LSS0.03-0.4-Y/Q |
LSS0.05-0.7-Y/Q |
LSS0.1-0.7-Y/Q |
LSS0.2-0.7-Y/Q |
LSS0.3-0.7-Y/Q |
|
Boiler horsepower |
1.9 HP |
3.2 HP |
6.4 HP |
12.8 HP |
19 HP |
|
Rated steam output |
30 KG/HOUR |
50 KG/HOUR |
100 KG/HOUR |
200 KG/HOUR |
300 KG/HOUR |
|
Maximum working pressure (manual reset) |
<0.4MPa / 58PSI |
<0.7MPa / 102PSI |
<0.7MPa / 102PSI |
<0.7MPa / 102PSI |
<0.7MPa / 102PSI |
|
Saturated steam temperature |
<140°C |
<172°C |
<172°C |
<172°C |
<172°C |
|
Material of main body |
20# carbon steel |
20# carbon steel |
20# carbon steel |
20# carbon steel |
20# carbon steel |
|
Thickness of main body |
6mm |
8mm |
8mm |
10mm |
10mm |
|
Thermal efficiency |
>89% |
>89% |
>89% |
>89% |
>89% |
|
Fuel consumption |
0# diesel |
2kg/h |
3.4kg/h |
6.8kg/h |
13.6kg/h |
20.2kg/h |
Natural gas |
2.4Nm3/h |
4Nm3/h |
8Nm3/h |
16Nm3/h |
24Nm3/h |
|
LPG |
1.6kg/h |
2.7kg/h |
5.4kg/h |
10.8kg/h |
16kg/h |
|
Dimensions after installation |
Φ |
780mm |
820mm |
980mm |
1050mm |
1050mm |
H |
1150mm |
1290mm |
1810mm |
1990mm |
1990mm |
|
Packing dimensions |
L |
650mm |
900mm |
890mm |
950mm |
950mm |
W |
850mm |
770mm |
1050mm |
1050mm |
1050mm |
|
H |
1150mm |
1300mm |
1700mm |
1940mm |
1940mm |