Features:
MODEL | ELG-75-12 | ELG-75-24 | ELG-75-36 | ELG-75-42 | ELG-75-48 | |
OUTPUT | DC VOLTAGE | 12V | 24V | 36V | 42V | 48V |
CONSTANT CURRENT REGION | 6 ~ 12V | 12 ~ 24V | 18 ~ 36V | 21 ~ 42V | 24 ~ 48V | |
RATED CURRENT | 5A | 3.15A | 2.1A | 1.8A | 1.6A | |
RATED POWER | 200VAC ~ 305VAC | |||||
60W | 75.6W | 75.6W | 75.6W | 76.8W | ||
100VAC ~ 180VAC | ||||||
48W | 60W | 60W | 60W | 60W | ||
RIPPLE & NOISE | 150mVp-p | 200mVp-p | 250mVp-p | 250mVp-p | 250mVp-p | |
VOLTAGE ADJ. RANGE | Adjustable for A-Type only (via built-in potentiometer) | |||||
10.8 ~ 13.2V | 21.6 ~ 26.4V | 32.4 ~ 39.6V | 37.8 ~ 46.2V | 43.2 ~ 52.8V | ||
CURRENT ADJ. RANGE | Adjustable for A-Type only (via built-in potentiometer) | |||||
2.5 ~ 5A | 1.57 ~ 3.15A | 1.05 ~ 2.1A | 0.9 ~ 1.8A | 0.8 ~ 1.6A | ||
VOLTAGE TOLERANCE | ±3.0% | ±3.0% | ±2.5% | ±2.5% | ±2.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 500ms, 100ms/115VAC, 230VAC | |||||
HOLD UP TIME | 10ms/ 230VAC 10ms/ 115VAC(at full load) | |||||
INPUT | VOLTAGE RANGE | 100 ~ 305VAC 142 ~ 431VDC | ||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||
POWER FACTOR | PF≥0.97/115VAC, PF≥0.95/230VAC, PF≥0.92/277VAC@full load | |||||
TOTAL HARMONIC DISTORTION | THD< 20%(@load≥50%/115VC,230VAC; @load≥75%/277VAC) | |||||
EFFICIENCY | 85% | 88% | 89% | 90% | 90% | |
AC CURRENT | 0.7A / 115VAC 0.45A / 230VAC 0.38A/277VAC | |||||
INRUSH CURRENT | COLD START 50A(twidth=350μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | |||||
Max. No. of PSUs on 16A CIRCUIT BREAKER | 5 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC | |||||
LEAKAGE CURRENT | <0.75mA / 277VAC | |||||
NO LOAD / STANDBY POWER CONSUMPTION | No load power consumption <0.5W for Blank / A / Dx / D2-Type Standby power consumption <0.5W for B / DA-Type | |||||
PROTECTION | OVER CURRENT | 95 ~ 108% | ||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |||||
OVER VOLTAGE | 14 ~ 18V | 28 ~ 34V | 41 ~ 48V | 47 ~ 54V | 54 ~ 62V | |
Protection type : Shut down o/p voltage, re-power on to recovery | ||||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recovery | |||||
ENVIRONMENT | WORKING TEMP. | Tcase= -40 ~ +85°C (Refer to "Derating Curve") | ||||
MAX. CASE TEMP. | Tcase= +85°C | |||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||
STORAGE TEMP., HUMIDITY | -40 ~ +80°C , 10 ~ 95% RH | |||||
TEMP. COEFFICIENT | ±0.03%/°C (0~50°C) | |||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||
SAFETY & EMC | SAFETY STANDARDS | U8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; IP65 or IP67; GB19510.1, GB19510.14 approved | ||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC | |||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | |||||
EMC EMISSION | Compliance to EN55015, EN61000-3-2 Class C (≥50% loading) ; EN61000-3-3, GB17743, GB17625.1 | |||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV) | |||||
OTHERS | MTBF | 331K hrs min. MIL-HDBK-217F (25°C ) | ||||
DIMENSION | 180*63*35.5 mm (L*W*H) | |||||
PACKING | 0.7Kg; 16pcs / 12.2kg / 0.67CUFT |
Mechanical Specification:
Other Series for Choose:
More Products for Choose:
Q1. Are you original Mean Well Power Supply?
A: Yes, We sell 100% Genuine Mean Well. And there are 2 method to identify:
Method 1: The Original Brand Logo is 'Mean Well', not 'MiWi' 'MeanWell' or 'MingWei' etc.
Method 2: Each product has an unique Serial No. on it, which can be checked in Mean Well official website. (For more information, please contact our sales. )
Q2: Do you offer guarantee for the products?
A: Yes, we offer 2 ~ 7 years warranty.
If the goods have quality problem during warranty period, we provide maintenance service.
If you have using problem, welcome to contact us for help.
Q3. Can I have a sample order firstly? What is your MOQ limit?
A: Yes, sample order is acceptable. And we do not have MOQ limit. Welcome to inquiry.
Q4. What about the lead time and shippment?
A: For common type like APV, LPV, ELG, LRS, DR, MDR series, we have enough stock. Sample Order can be delivered within 3 days, Bulk Order can be delivered within 3~7 days after payment, not common type need 10~35 days after payment, for detail lead time, please contact our sales.
For shipping, we often use DHL, FedEx, UPS, and TNT. And they take 3-5 days to arrive. For bulk order, we recommend to send goods by Air or by Sea to save your transportation cost.
Q5: What is your payment terms?
A: We accept pay via Bank Transfer, Paypal and Western Union.
For bulk order, if the lead time is long, we also accept 30% in advance, and 70% balance before shipping.
We also accept Trade Assurance online to get 100% guarantee for your orders.
(For more details, please contact us)
Q6. How to proceed an order?
A: 1. Inquiry: Tell us your requirements, such as model No, Quantity and delivery address...
2. Quotation: We will quote you soon according to your requirements.
3. Confirmation: If quotation is OK, we will send PI to you for payment.
4. Payment: After your payment, please give us your bank slip, then we can arrange goods for you soon.
5. Delivery: Once get your payment and goods all ready, we will delivery goods soon, and tell you the tracking number or Vessel No. then (For more details, please contact us.)