Brand New Dc Digital Voltmeter Module Digital Voltmeter Display Module 3Phase Panel Voltmeter Rs485 Panel Meter
Model | Dimension | Measurement range | Code |
DA8-AV | 48H×96W×58L | AC Voltage:20/200/600 | B0300DA01 |
DA8-DV | DC Voltage:0.2/2/20/200/600 | B0300DA01 | |
DA8-AA | AC Current:0.2/2/20/200 | B0300DA01 | |
DA8-DA | DC Current:0.0002/0.002/0.02/0.2/2/20 | B0300DA01 |
Input | Please refer to the range description |
Accuracy | AC:±0.3%F.S±3Digits DC:±0.2%F.S±3Digits |
A/D switch | Double integral |
Sampling rate | About 2.5times/second |
Input impedance | Refer to measuring specifications table |
Display range | 0~±19999,Decimal point can switch through pin of PCB board |
Display | 4 1/2 red LED 0.56 inch |
Overflow indication | Display“1”or“-1” |
Environment | 0℃~50℃ 35~85%RH |
Storage environment | -20℃~60℃ 35~90%RH |
Power | AC 100~240V 50/60Hz |
Power consumption | ≤3W |
Dielectric strength | AC 1500V 1min 50Hz |
Insulation strength | 100MΩ DC 500V |
Dimension | 48H×96W×58L |
Vibration | Sweep-frequency vibration:10~50HZ |
Weight |
0.5kg |
Type | Range | Input | Resolution | Input Impendance |
AC Accuracy Level |
AC Accuracy Level |
Voltage Signal | 200mV | Direct input | 0.01mV | 200KΩ | ±0.3%F.S ±3Digits | ±0.2%F.S ±3Digits |
2V | Direct input | 0.1mV | 2MΩ | ±0.3%F.S ±3Digits | ±0.2%F.S ±3Digits | |
20V | Direct input | 1mV | 2MΩ | ±0.3%F.S ±3Digits | ±0.2%F.S ±3Digits | |
200V | Direct input | 10mV | 2MΩ | ±0.3%F.S ±3Digits | ±0.2%F.S ±3Digits | |
600V | Direct input | 100mV | 5.1MΩ | ±0.5%F.S ±3Digits | ±0.3%F.S ±3Digits | |
Current Signal | 2mA | Direct input | 0.0001mA | 100Ω | ±0.3%F.S ±3Digits | ±0.2%F.S ±3Digits |
20mA | Direct input | 0.001mA | 10Ω | ±0.3%F.S ±3Digits | ±0.2%F.S ±3Digits | |
200mA | Direct input | 0.01mA | 1Ω | ±0.3%F.S ±3Digits | ±0.2%F.S ±3Digits | |
2A | Direct input | 0.1mA | 0.2Ω | ±0.3%F.S ±3Digits | ±0.2%F.S ±3Digits | |
Above AC 5A |
AC 0~5A input (ratio display) |
1mA | 2mΩ | ±0.3%F.S ±3Digits | ||
Above DC 2A |
DC 0~75mV input (ratio display) |
1mA | 100KΩ | ±0.2%F.S ±3Digits | ||
Note:When the measured voltage > 600V, it must be changed to AC 0 ~100V input by 100V ratio voltage transformer and the meter will display the ratio value. |
FAQ
Q1.Can you produce according to the samples or drawings?
Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.
Q2.What is your terms of payment?
Usually,we accept T/T, irrevocable L/C at sight. For regular orders, Terms of payment 30% deposit, full payment before delivery the goods.
Q3.What is the lead time?
For standard models, lead time is about 3~5 days after order confirmed and payment received.
For OEM orders, the delivery is about 2~3 weeks after data confirmed and payment received.
Q4.What is your terms of packing?
Under TOKY brand, the standard packing is 1pc item in a colour box or brown inner box, then into standard export carton.
For OEM order, usually 1pc item in a brown inner box, then into standard export carton.
Q5.What is your terms of delivery?
We accept EXW,FOB,CIF,etc. You can choose the one which is the most convenient or cost effective for you.
Q6.How to solve the quality problems after sales?
Take photos or videos of the problems and send to us.
We will make a satisfied solution for you within 24 hours after we confirm the problems.
Q7.Do you have any MOQ limit for the order?
Low MOQ, 1pc for sample checking is available.
Q8.Is it OK to print my logo on the product?
Yes, OEM service is available.
Please confirm with our sales team formally before production and confirm the design firstly based on our sample.
Q9.Are you manufacturer or trading company?
We are manufacturer for over 30 years. Welcome to visit our factory at anytime.