Section | Overall Diameter | Cable Weight | Radius of Bend | Electrical Resistance | Current Carrying Capacity in Air |
No.xmm2 | mm | kg/km | mm | Q/km | A |
2x16 | 17 | 140 | 255 | 1,910 | 75 |
2x25 | 20 | 200 | 300 | 1,200 | 116 |
2x35 | 23 | 275 | 345 | 0.868 | 140 |
3x16 | 17 | 210 | 255 | 1,910 | 69 |
3x25 | 21 | 300 | 315 | 1,200 | 107 |
4x16 | 19 | 280 | 285 | 1,910 | 69 |
4x25 | 22 | 410 | 330 | 1,200 | 107 |
4x35 | 25 | 550 | 380 | 0.868 | 132 |
4x50 | 28 | 750 | 420 | 0.641 | 165 |
4x70 | 32 | 1000 | 480 | 0.443 | 205 |
4x95 | 38 | 1350 | 570 | 0.32 | 250 |
4x120 | 41 | 1680 | 620 | 0.253 | 280 |
4x35+1x25 | 28 | 623 | 420 | 0.866+1.200 | 130 |
4x50+1x25 | 30 | 805 | 450 | 0.641+1.200 | 161 |
4x70+1x25 | 33 | 1062 | 500 | 0.443+1.200 | 205 |
4x70+1x35 | 34 | 1093 | 500 | 0.443+0.868 | 205 |
4x95+1x25 | 38 | 1434 | 570 | 0.32+1.200 | 250 |
4x120+1x25 | 42 | 1723 | 630 | 0.253+1.200 | 280 |
4x50+2x16 | 32 | 859 | 480 | 0.641+1.910 | 161 |
4x70+2x16 | 36 | 1116 | 540 | 0.443+1.910 | 205 |
4x70+2x25 | 37 | 1154 | 550 | 0.443+1.200 | 205 |
4x95+2x16 | 40 | 1489 | 600 | 0.320+1.910 | 250 |
4x120+2x16 | 45 | 1787 | 680 | 0.253+1.910 | 280 |
ABC Cables Without Street Lighting | ||||||||||||||
1+1 Structure | ||||||||||||||
Phase Conductor | Neutral Conductor | Completed Cable | ||||||||||||
Section | Insulation | Electrical Resistance | Section | Insulation | Electrical Resistance | Overall Diameter | Cable Weight | |||||||
Thickness | Thickness | |||||||||||||
DC.20°C | DC.20°C | |||||||||||||
No.xmm2 | mm | Q/km | mm2 | mm | Q/km | mm | kg/km | |||||||
1x25 | 1.3 | 1.2 | 25 | 1.3 | 1.2 | 17.6 | 210 | |||||||
1x35 | 1.3 | 0.868 | 35 | 1.3 | 0.868 | 19.6 | 270 | |||||||
1x50 | 1.5 | 0.641 | 50 | 1.5 | 0.641 | 23 | 360 | |||||||
1x70 | 1.5 | 0.443 | 70 | 1.5 | 0.443 | 26.4 | 500 | |||||||
1x95 | 1.7 | 0.32 | 95 | 1.7 | 0.32 | 30.6 | 680 | |||||||
3+1 Structure | ||||||||||||||
Phase Conductor | Neutral Conductor | Completed Cable | ||||||||||||
Section | Insulation Thickness | Electrical Resistance | Section | Insulation Thickness | Electrical Resistance | Overall Diameter | Cable Weight | |||||||
Thickness | Thickness | |||||||||||||
DC.20°C | DC.20°C | |||||||||||||
No.xmm2 | mm | Q/km | mm2 | mm | Q/km | mm | kg/km | |||||||
3x25 | 1.3 | 1.2 | 25 | 1.3 | 1.2 | 21.2 | 410 | |||||||
3x35 | 1.3 | 0.868 | 35 | 1.3 | 0.868 | 23.7 | 550 | |||||||
3x50 | 1.5 | 0.641 | 50 | 1.5 | 0.641 | 27.8 | 730 | |||||||
3x70 | 1.5 | 0.443 | 70 | 1.5 | 0.443 | 31.9 | 1000 | |||||||
3x95 | 1.7 | 0.32 | 95 | 1.7 | 0.32 | 36.9 | 1370 | |||||||
3x120 | 1.7 | 0.253 | 120 | 1.7 | 0.253 | 40.6 | 1690 | |||||||
3+1+1 Structure | ||||||||||||||
Phase Conductor | Neutral Conductor | Street Lighting Conductor | Completed Cable | |||||||||||
Section | Insulation Thickness | Section | Insulation | Section | Insulation Thickness | Overall Diameter | Cable Weight | |||||||
Thickness | Thickness | |||||||||||||
No.xmm2 | mm | mm2 | mm | mm2 | mm | mm | kg/km | |||||||
3x50 | 1.5 | 50 | 1.5 | 25 | 1.3 | 29.8 | 830 | |||||||
3x70 | 1.5 | 70 | 1.5 | 25 | 1.3 | 33.6 | 1100 | |||||||
3x95 | 1.7 | 95 | 1.7 | 25 | 1.3 | 38.2 | 1470 |
AS/NZS-3560.1 | ||||||||||||||
LV XLPE Insulated 2/3/4 Core Aluminium ABC | ||||||||||||||
Section | Conductor Diameter | Insulation Thickness | Electrical Resisdence | Cable Weight | Rated Strength | Modulus of | Coeff. of Linear Expansion | |||||||
Thickness | Resistance | Elasticity | ||||||||||||
No.xmm2 | mm | mm | DC.20°C | kg/km | kN | GPa | xlO-6/°C | |||||||
Q/km | ||||||||||||||
2x16 | 4.7 | 1.3 | 1.91 | 130 | 4.4 | 59 | 23 | |||||||
2x25 | 5.9 | 1.3 | 1.2 | 190 | 7 | 59 | 23 | |||||||
2x35 | 6.9 | 1.3 | 0.868 | 250 | 9.8 | 59 | 23 | |||||||
2x50 | 8.1 | 1.5 | 0.641 | 340 | 14 | 59 | 23 | |||||||
2x95 | 11.4 | 1.7 | 0.32 | 640 | 26.6 | 56 | 23 | |||||||
3x25 | 5.9 | 1.3 | 1.2 | 290 | 10.5 | 59 | 23 | |||||||
3x35 | 6.9 | 1.3 | 0.868 | 370 | 14.7 | 59 | 23 | |||||||
3x50 | 8.1 | 1.5 | 0.641 | 510 | 21 | 59 | 23 | |||||||
4x16 | 4.7 | 1.3 | 1.91 | 270 | 8.8 | 59 | 23 | |||||||
4x25 | 5.9 | 1.3 | 1.2 | 390 | 14 | 59 | 23 | |||||||
4x35 | 6.9 | 1.3 | 0.868 | 500 | 19.6 | 59 | 23 | |||||||
4x50 | 8.1 | 1.5 | 0.641 | 670 | 28 | 59 | 23 | |||||||
4x70 | 9.7 | 1.5 | 0.443 | 930 | 39.2 | 56 | 23 | |||||||
4x95 | 11.4 | 1.7 | 0.32 | 1280 | 53.2 | 56 | 23 | |||||||
4x120 | 12.8 | 1.7 | 0.253 | 1570 | 67.2 | 56 | 23 | |||||||
4x150 | 14.2 | 1.7 | 0.206 | 1890 | 84 | 56 | 23 | |||||||
AS/NZS-3560.2 | ||||||||||||||
LV XLPE Insulated 2/3/4 Core Copper ABC | ||||||||||||||
2x6 | 3.3 | 1.3 | 3.18 | 0.14 | 4.8 | 112 | 17 | |||||||
2x10 | 4.2 | 1.3 | 1.89 | 0.23 | 8 | 112 | 17 | |||||||
2x16 | 5.2 | 1.3 | 1.19 | 0.35 | 12.2 | 112 | 17 | |||||||
2x25 | 6.6 | 1.3 | 0.749 | 0.57 | 19.4 | 110 | 17 | |||||||
3x6 | 3.3 | 1.3 | 3.18 | 0.22 | 7.2 | 112 | 17 | |||||||
3x10 | 4.2 | 1.3 | 1.89 | 0.35 | 12 | 112 | 17 | |||||||
3x16 | 5.2 | 1.3 | 1.19 | 0.53 | 18.3 | 112 | 17 | |||||||
3x25 | 6.6 | 1.3 | 0.749 | 0.86 | 29.1 | 110 | 17 | |||||||
4x6 | 3.3 | 1.3 | 3.18 | 0.29 | 9.6 | 112 | 17 | |||||||
4x10 | 4.2 | 1.3 | 1.89 | 0.47 | 16 | 112 | 17 | |||||||
4x16 | 5.2 | 1.3 | 1.19 | 0.71 | 24.4 | 112 | 17 | |||||||
4x25 | 6.6 | 1.3 | 0.749 | 1.15 | 38.8 | 112 | 17 | |||||||
AS/NZS-5000.2 | ||||||||||||||
PVC Insulated Flat Aerial Cables 1/2/3 Core Copper | ||||||||||||||
1x6 | 3.1 | 1 | 80 | 3.17 | 2.3 | 112 | 17 | |||||||
1x10 | 4.1 | 1 | 120 | 1.88 | 3.9 | 112 | 17 | |||||||
1x16 | 5.1 | 1 | 180 | 1.18 | 5.9 | 112 | 17 | |||||||
1x25 | 6.8 | 1.2 | 300 | 0.749 | 10.4 | 110 | 17 | |||||||
1x35 | 7.7 | 1.2 | 370 | 0.54 | 12.7 | 110 | 17 | |||||||
1x50 | 8.9 | 1.4 | 510 | 0.399 | 17.3 | 110 | 17 | |||||||
1x70 | 10.7 | 1.4 | 710 | 0.276 | 25 | 110 | 17 | |||||||
2x6 | 3.1 | 1 | 150 | 3.17 | 4.6 | 112 | 17 | |||||||
2x10 | 4.1 | 1 | 240 | 1.88 | 7.8 | 112 | 17 | |||||||
2x16 | 5.1 | 1 | 360 | 1.18 | 11.8 | 112 | 17 | |||||||
2x25 | 6.8 | 1.2 | 600 | 0.749 | 20.8 | 110 | 17 | |||||||
3x6 | 3.1 | 1 | 230 | 3.17 | 7 | 112 | 17 | |||||||
3x10 | 4.1 | 1 | 360 | 1.88 | 11.8 | 112 | 17 | |||||||
3x16 | 5.1 | 1 | 540 | 1.18 | 17.8 | 112 | 17 |
3x25 | 6.8 | 1.2 | 910 | 0.749 | 31.2 | 110 | 17 |
4x6 | 3.1 | 1 | 310 | 3.17 | 9.3 | 112 | 17 |
4x10 | 4.1 | 1 | 480 | 1.88 | 15.7 | 112 | 17 |
4x16 | 5.1 | 1 | 730 | 1.18 | 23.7 | 112 | 17 |
4x25 | 6.8 | 1.2 | 1210 | 0.749 | 41.6 | 110 | 17 |
Description | Conductor | Cable | ||||||||||||||
Type | Section | Electrical Resistance | Conductor Diameter | Rated Strength | Current Carrying Capacity | Insulation Thickness | Overall Diameter | |||||||||
mm2 | DC.20°C | Min. | Max. | Min. | Max. | |||||||||||
Q/km | mm | mm | daN | A | mm | mm | mm | |||||||||
Phases and Public Lighting | 16 | 1.91 | 4.6 | 5.1 | 190 | 70 | 1.2 | 7 | 7.8 | |||||||
25 | 1.2 | 5.8 | 6.3 | 300 | 90 | 1.4 | 8.6 | 9.4 | ||||||||
35 | 0.868 | 6.8 | 7.3 | 115 | 1.6 | 10 | 10.9 | |||||||||
50 | 0.641 | 7.9 | 8.4 | 140 | 1.6 | 11.1 | 12 | |||||||||
70 | 0.443 | 9.7 | 10.2 | 180 | 1.8 | 13.3 | 14.2 | |||||||||
95 | 0.32 | 11 | 12 | 215 | 1.8 | 14.6 | 15.7 | |||||||||
120 | 0.253 | 12 | 13.1 | 250 | 1.8 | 15.6 | 16.7 | |||||||||
150 | 0.206 | 13.9 | 15 | 290 | 1.7 | 17.3 | 18.6 | |||||||||
Neutral (Messenger) | 54.6 | 0.63 | 9.2 | 9.6 | 1660 | 1.6 | 12.3 | 13 | ||||||||
70 | 0.5 | 10 | 10.2 | 2050 | 1.5 | 12.9 | 13.6 | |||||||||
95 | 0.343 | 12.2 | 12.9 | 2750 | 1.6 | 15.3** | 16.3** | |||||||||
Special Neutral (Compacted) | 54.6 | 0.63 | 8.4 | 9.2 | 1660 | 1.6 | 11.6 | 12.5 | ||||||||
70 | 0.5 | 9.4 | 9.8 | 2050 | 1.5 | 12.4 | 13 | |||||||||
95 | 0.343 | 11.2 | 12 | 2750 | 1.6 | 14.4 | 15.2 |
Structure | Insulated conductors | Public Lighting | Messenger | Complete cable | ||||||||
Section | Electrical Resistance | Insulation Thickness | Section | Rated Strength | Electrical Resistance | Diameter | Cable Weight | |||||
No.xmm2 | DC.20°C | mm | No.xmm2 | kN | DC.20°C | mm | kg/km | |||||
Q/km | ohm/km | |||||||||||
1x10+16 | 1x10 | 2.85 | 1.4 | 4.7 | 2.15 | 10 | 90 | |||||
1x16+25 | 1x16 | 1.91 | 1.4 | 7.4 | 1.38 | 15 | 140 | |||||
1x25+35 | 1x25 | 1.20 | 1.4 | 10.3 | 0.986 | 17 | 200 | |||||
1x35+50 | 1x35 | 0.868 | 1.6 | 14.2 | 0.720 | 20 | 275 | |||||
1x50+70 | 1x50 | 0.641 | 1.6 | 20.6 | 0.493 | 22 | 350 | |||||
1x70+95 | 1x70 | 0.443 | 1.8 | 27.9 | 0.363 | 25 | 505 | |||||
3x10+16 | 3x10 | 2.85 | 1.4 | 4.7 | 2.15 | 14 | 180 | |||||
3x16+25 | 3x16 | 1.91 | 1.4 | 7.4 | 1.38 | 22 | 270 | |||||
3x25+35 | 3x25 | 1.20 | 1.4 | 10.3 | 0.986 | 26 | 390 | |||||
3x35+50 | 3x35 | 0.868 | 1.6 | 14.2 | 0.720 | 30 | 530 | |||||
3x50+70 | 3x50 | 0.641 | 1.6 | 20.6 | 0.493 | 35 | 700 | |||||
3x70+95 | 3x70 | 0.443 | 1.8 | 27.9 | 0.363 | 41 | 990 | |||||
3x120+95 | 3x120 | 0.253 | 2.0 | 27.9 | 0.363 | 47 | 1510 | |||||
1x16+1x16+25 | 1x16+1x16 | 1.91 | 1.4 | 1x16 | 7.4 | 1.38 | 16 | 205 | ||||
3x16+1x16+25 | 3x16+1x16 | 1.91 | 1.4 | 1x16 | 7.4 | 1.38 | 22 | 335 | ||||
3x25+1x16+35 | 3x25+1x16 | 1.20 | 1.4 | 1x16 | 10.3 | 0.986 | 26 | 455 | ||||
3x35+1x16+50 | 3x35+1x16 | 0.868 | 1.6 | 1x16 | 14.2 | 0.720 | 30 | 595 | ||||
3x50+1x16+70 | 3x50+1x16 | 0.641 | 1.6 | 1x16 | 20.6 | 0.493 | 35 | 765 | ||||
3x70+1x16+95 | 3x70+1x16 | 0.443 | 1.8 | 1x16 | 27.9 | 0.363 | 41 | 1055 | ||||
3x120+1x16+95 | 3x120+1x16 | 0.253 | 2.0 | 1x16 | 27.9 | 0.363 | 47 | 1600 | ||||
4x16+25 | 4x16 | 1.91 | 1.4 | 7.4 | 1.38 | 22 | 330 | |||||
4x25+35 | 4x25 | 1.20 | 1.4 | 10.3 | 0.986 | 26 | 490 | |||||
4x35+50 | 4x35 | 0.868 | 1.6 | 14.2 | 0.720 | 30 | 660 | |||||
4x50+70 | 4x50 | 0.641 | 1.6 | 20.6 | 0.493 | 35 | 870 | |||||
4x70+95 | 4x70 | 0.443 | 1.8 | 27.9 | 0.363 | 41 | 1235 |