Model | S-60-5 | S-60-12 | S-60-15 | S-60-24 |
---|---|---|---|---|
Specification | ||||
DC output voltage |
5V
|
12V
|
15V
|
24V
|
Output voltage error(Note 2) |
±2%
|
±1%
|
±1%
|
±1%
|
Rated output current |
12A
|
5A
|
4A
|
2.5A
|
Output current rage |
0-12A
|
0-5A
|
0-4A
|
0-2.5A
|
Wave and noise(Note 3) |
120mVp-p
|
120mVp-p
|
150mVp-p
|
150mVp-p
|
Inlet stability(Note 4) |
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
Load stablity (Note 5) |
±1%
|
±0.5%
|
±0.5%
|
±0.5%
|
DC output power |
60W
|
60W
|
60W
|
40W
|
Efficiency |
72%
|
76%
|
77%
|
79%
|
Adjustable range for DC voltage |
+10,-5%
|
+10%
|
+10%
|
+10%
|
AC input voltage range | 85-264VAC 47-63Hz 120-370VDC | |||
Input current | 2A/115V 60A/230V | |||
AC INnrush current |
Cold-start current 30A/115V 60A/230V |
|||
Leakage current | <3.5mA/240VAC | |||
Overload proctection | 105%~150% Tpye pulsing hiccp shutdown Reset:auto recovery | |||
Over-voltage protection | 115%~135% | |||
High-temperature protection | ………… | |||
Temperature coefficient | ±0.03%/°C(0~50%) | |||
Setup rise hold up time | 800ms,50ms,10ms/115V 300ms,50ms,80ms/230VAC | |||
Vibration | 10-500HZ,2G 10min,/1cycle,Period for 60min,Each axes | |||
Withstand voltage | Input and output internal ,1.5KVAC,Input and enclosure,.5KVAC,Output and enclosure,0.5KVAC | |||
Isolation resistance | Input and output internal,Input and enclosure,Output and enclosure,500VDC/100MΩ | |||
Working temperature and humidity | -10°C~+60°C(Refer to output derating curve),20%~90%RH | |||
Store temperature and humidity | -20°C~+85°C,10%~95%RH | |||
Overall dimension | 159×97×38mm | |||
Weight | 0.55Kgs | |||
Safety standards | UL1012 TUV EN6050(IEC,UL1950)Approved | |||
EMC standards | CISPR22(EN55022),IEC801-2,3,4,IEC555-2 Verification | |||
Note 1.The testing condition for the paramenter above is ,230VAC input,rated load,25°C70% RH.Humidity. 2.Error.include the setting error,line stability and load stability.(Note:5). 3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. 4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. 5.Load stability test:the load is from 0% to 100%. 6.C2,3,6 must be knocked down. |
Single Output Type |
|
Newest Type LRS-35W LRS-50W LRS-75W LRS-100W LRS-150W |
|
Din Rain Type DR-30W DR-45W DR-60W DR-75W DR-120W DRP-240W DRT-240W LP-100~500W |
|
Waterproof Type |
|
Mini Type |
|
High Efficiency Type |
|
Multiple Type |
|
PFC function type |