Pure sine wave output, true on-line dual conversion design
Adopt 4 layer PCB, and SMD technology
High efficiency IGBT (Insulated Gate Bipolar Transistor) inverter technology.
The sixth generation low-exhaust and big-power IGBT with excellent high speed switch feature, high voltage feature and large current feature. Drives by electric voltage, only need small control power. The sixth generation with lower saturation voltage, the inverter has high efficiency, low temperature, high reliability.
Touch screen display, with simple operation and Intuitive data, optional display language and logo.
Set work modes on the display directly, UPS mode, ECO mode, EPS mode
Intelligent detecting function
This system microprocessor can continually online detect power status, the breaker status and all the working status of the circuit
Excellent load feature Completely capable to load from 0-100% while no need to change to bypass, which make sure the output reliable.
Isolation Transformer in output for Better Performance
Static & Manual Bypass Inbuilt
Three phase separately control, realizes the control of instantaneous over-loading balance, so as to reach 100% unbalanced load.
DC cold start function
When mains failure, can directly use the battery to start the ups until the battery discharge to low voltage, when mains recover, can self start UPS
Generator compatible
According to the real electric circumstances, UPS can be compatible to the generator, highly improve the generator input efficiency, save the energy.
Intelligent communication
With RS232 and RS485 standard collocation, optional SNMP and dry contact
Perfect protection.
Input/output over/low voltage protection, input surge protection, phase sequence protection, battery over charge/discharge protection, short circuit protection, over-temperature protection and so on, as well as alarm function.
Selectable battery inspection module
Can test the single parameter and display on the LCD, battery failure will immediately alarm and inform the administrator
High-powered dynamic feature
Adopt kinds of feedback control such as instantaneous control mode and virtual value, not only reach the high dynamic adjustment, but also reduce the output voltage distortion.
Optional input harmonic filter or 12 pulse rectifier
Effectively restrain the input THD,raise UPS input power factor, reduce the input THD current
Capacity(KVA) |
10 |
15 |
20 |
25 |
30 |
40 |
50 |
60 |
80 |
100 |
120 |
160 |
200 |
250 |
300 |
400 |
500 |
600 |
Power Watt(KW) |
8 |
12 |
16 |
20 |
24 |
32 |
40 |
48 |
64 |
80 |
96 |
128 |
160 |
200 |
240 |
320 |
400 |
480 |
Working Principle |
Low Frequency Transformer Based True On Line-Double Conversion |
|||||||||||||||||
RECTIFIER (INPUT) |
||||||||||||||||||
Phase |
Three Phase |
|||||||||||||||||
Input Power Factor |
Standard more than 0.9 ( 6pulse Rectifier+Filter ), Optional more than 0.96 ( 12pulse Rectifier+Filter) |
|||||||||||||||||
Input Voltage Range |
220/380VAC (230V/400VAC or 240V/415VAC)±25% 3P+N+PE ; 110V/208VAC( 120V/220VAC or 277V/480VAC ) optional |
|||||||||||||||||
Input Frequency Range |
50Hz±10% / 60Hz±10% (Selectable) |
|||||||||||||||||
Total Harmonic Distortion (THDi) |
6pulse Rectifier<30%, Optional 12pulse Rectifier & Filter<5% |
|||||||||||||||||
Output Ripple |
<2% |
|||||||||||||||||
Soft Start |
0~100% 5sec |
|||||||||||||||||
CHARGING |
||||||||||||||||||
Charging Mode |
Constant current, then constant voltage, charge with temperature compensation, automatic switch Between Equalized charging and Float charging, |
|||||||||||||||||
Float Charging Voltage |
432VDC |
|||||||||||||||||
Equalized Charging Voltage |
464VDC |
|||||||||||||||||
Temp. Compensated Voltage |
-3mV/℃/cell |
|||||||||||||||||
Charging Current |
0.1C ( Automatic adjust according to battery capacity) |
|||||||||||||||||
BATTERY |
||||||||||||||||||
Type |
VRLA/AGM/Gel, optional Lithium Battery |
|||||||||||||||||
Battery Capacity |
7~999AH settable (Configuration Battery Capacity according to Back-up Time) |
|||||||||||||||||
Quantity |
32units 12V or 192units 2V batteries (Nominal Voltage 384VDC) |
|||||||||||||||||
Temperature |
20ºC~25ºC (For Maximum Efficiency) |
|||||||||||||||||
INVERTER (OUTPUT) |
||||||||||||||||||
Phase |
Three Phase |
|||||||||||||||||
Rated Voltage |
Rated Capacity*0.9 |
|||||||||||||||||
Nominal Voltage |
220/380VAC (230V/400VAC or 240V/415VAC), 3P+N 110V/208VAC( 120V/220VAC or 277V/480VAC ) optional |
|||||||||||||||||
Output Voltage Regulated Accuracy |
±1%( Stable load), ±3%( fluctuant load) |
|||||||||||||||||
Output Frequency Range |
50Hz 60Hz<±0.5% ( Asynchronous ) |
|||||||||||||||||
Crest Factor |
> 3:1 |
|||||||||||||||||
Output Total Harmonic Distortion (THDi) |
Pure Sine Wave, Linear Load< 3%, Non-Linear Load<5% |
|||||||||||||||||
Dynamic Characteristics |
Instant voltage<±5% ( from 0 to100% ), Instant recover time<10ms |
|||||||||||||||||
Unbalanced Load Voltage |
< ±5% |
|||||||||||||||||
Overload Capacity |
At 115% load, normal work, At 125% load 10 min, At 150% load 1min, At 200% load 1S |
|||||||||||||||||
Inverter Efficiency |
>92% ( full load ) |
>93% ( full load ) |
>95% ( full load ) |
|||||||||||||||
BYPASS |
||||||||||||||||||
Phase |
3 Phase +N |
|||||||||||||||||
Input Nominal Voltage |
220/380VAC (230V/400VAC or 240V/415VAC) 110V/208VAC( 120V/220VAC or 277V/480VAC ) optional |
|||||||||||||||||
Output Nominal Voltage |
220/380VAC (230V/400VAC or 240V/415VAC) 110V/208VAC( 120V/220VAC or 277V/480VAC ) optional |
|||||||||||||||||
Transfer Time |
0ms( adopt static switch ) |
|||||||||||||||||
PROTECTION FUNCTION |
||||||||||||||||||
Input Protection |
Input voltage, frequency over limited protection, Phase fault, Phase lack |
|||||||||||||||||
Output Protection |
Over current, short circuit, over voltage, low voltage |
|||||||||||||||||
Battery Protection |
Over charge, over-discharge protection |
|||||||||||||||||
Temperature Protection |
Environment over temperature protection, inverter over temperature protection |
|||||||||||||||||
Hardware Fault Protection |
Assistant power abnormal, breaker cut off, breaker overload, power devices over current/over voltage etc protection |
|||||||||||||||||
GENERAL SYSTEM PARAMETERS |
||||||||||||||||||
Working Environment |
Temp: -10~40ºC, relative humidity: 30%~90%, Altitude<2000m ( 1% decrease against 100 meters’ rise, max. altitude 4000m ) |
|||||||||||||||||
Cooling Method |
COMPULSIVE VENTILATION |
|||||||||||||||||
Communication Interface |
RS232/ RS485, optional dry contact, SNMP card ( for remote control via Internet) |
|||||||||||||||||
Parallel Operation |
Tandem hot backup or parallel connection |
|||||||||||||||||
Auti-surge Capacity |
10/700μS, 5KV; 8/20μS, 20KA |
|||||||||||||||||
Protection Level |
IP31 |
IP30 |
||||||||||||||||
Safety Performance |
Vin-n Vout-n 3000Vac, creepage<3.5mA , insulating resistance>2MΩ(500VDC) |
|||||||||||||||||
Noise (dB) |
48~55 |
55~60 |
60~65 |
65~70 |
FAQ
Q: Why choose us?
A: We are China Leading ups&solar system Manufacturer, 14 years experience in producing and marketing
ups & solar products.
100% QC inspection Before Shipment.
Best Quality & Best Service with Competitive price.
Good after-sale service: 2 years warranty and if possible we provide on-site installation and repairing
All of our products have the CE certificate, ISO9001,ISO14001,OHSAS18000,TLC, IEC authentication, and Chinese energy conservation certification
Market covers the 100 cities and countries all over the world. Have branch office in Pakistan, Australia, etc.
If you have some problems about CHP series online ups , or want to know more details about 3 phase ups,3 phase ups system,480 volt 3 phase ups,apc 3 phase ups,3 phase ups circuit,lithium battery, solar inverter,etc. Welcome to contact us!
Looking forward to your inquiry in alibaba.