Enquiries
Message
Home > Products > Other
Automatic Dissipation Factor Meter 10 kV Transformer Capacitance Tan Delta Measuring Bridge
  • Automatic Dissipation Factor Meter 10 kV Transformer Capacitance Tan Delta Measuring Bridge

Automatic Dissipation Factor Meter 10 kV Transformer Capacitance Tan Delta Measuring Bridge

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin:
Hebei, China
Brand Name:
Weisheng
Model Number:
VS-2810
Power:
Electronic
Product name:
Transformer Tan Delta Tester (Dielectric Loss Tester)
Test current range:
10μA~1A
Range of tan delta:
Unlimited
Accuracy of Cx:
±(rdg*1%+1pF)
Accuracy of tan delta:
±(rdg*1%+0.00040)
Measuring time:
About 40s
Input power:
180V~270VAC, 50Hz±1%
Display mode:
Digital only
Dimensions:
460*360*350mm
Instrument weight:
28kg
Supply Ability
Supply Ability:
200 Piece/Pieces per Month
Packaging & Delivery
Product Description

Automatic Dissipation Factor Meter 10 kV Transformer Capacitance Tan Delta Measuring Bridge

Product details

Product name Transformer Tan Delta Tester (Dielectric Loss Tester)
Test current range 10μA~1A
Range of tan delta Unlimited
Accuracy of Cx ±(rdg*1%+1pF)
Accuracy of tan delta ±(rdg*1%+0.00040)
Measuring time About 40s
Input power 180V~270VAC, 50Hz±1%
Display mode Digital only
Dimensions 460*360*350mm
Instrument weight 28kg
Product Keywords capacitance tan delta measuring bridge,tangente delta meter ps-jsb01,dissipation factor meter

Technical Parameters

I. Overview

    Dielectric loss measurement is a very basic method in the insulation test, which can effectively find the overall damp deterioration of the electrical equipment insulation, as well as local defects. It is widely used in electrical manufacturing, electrical equipment installation, handover and preventive tests. The measurement of dielectric loss of transformers, transformers, reactors, capacitors, bushings, and lightning arresters is the most basic method to measure their insulation performance. 

    VS-2810 automatic anti-interference precision dielectric loss tester breaks through the traditional bridge measurement method, adopts variable frequency power supply technology, uses single-chip microcomputer and modern electronic technology to perform automatic frequency conversion, analog/digital conversion and data calculation; achieves strong anti-interference ability , Test speed, high precision, fully automatic digitization, easy operation; power supply adopts high-power switching power supply, output 45Hz and 55Hz pure sine wave, automatic pressure, can provide up to 10kV voltage; automatically filter out 50Hz interference, applicable It is used in substations and other field tests with large electromagnetic interference. It is widely used in the dielectric loss measurement of transformers, transformers, bushings, capacitors, arresters and other equipment in the power industry.

II. Features

    1. The instrument adopts complex current method to measure capacitance, dielectric loss and other parameters. The accuracy of the test results is high, and it is easy to realize automatic measurement.

    2. The instrument uses frequency conversion technology to eliminate the 50Hz power frequency interference, even in the environment of strong electromagnetic interference, it can also measure reliable data.

    3. The instrument adopts large screen LCD, and the test process is prompted by Chinese menu, which is intuitive and easy to operate.

    4. The instrument is easy to operate, and the measurement process is controlled by microprocessor. As long as the appropriate measurement method is selected, the data measurement can be completed automatically under the control of microprocessor.

    5. Integrated model, with standard capacitor and high voltage power supply, easy to field test and reduce field wiring.

    6. The instrument has high measurement accuracy and can meet the requirements of oil dielectric loss measurement. Therefore, only standard oil cup and special test line are needed to realize oil dielectric loss measurement.

    7. With CVT test function, CVT self-excited test can be realized, without external accessories, only one measurement is needed, and the capacitance and dielectric loss of C1 and C2 are all measured.

    8. Ivddv technology is used in the reverse wiring test, which eliminates the instability of the previous reverse wiring data.

    9. It has the function of reverse wiring low-voltage shielding. When the 220kV CVT bus is grounded, the 10kV reverse wiring dielectric loss of C11 can be measured without disconnection.

    10. It has the function of measuring high voltage dielectric loss, and can use high voltage transformer or series resonance to carry out dielectric loss test of more than 10KV voltage.

    11. Grounding protection function, when the instrument is not grounded or the grounding is poor, the instrument does not enter the normal program and does not output high voltage. With over-current protection function, the instrument will not be damaged in case of short circuit or breakdown.

    12. Electric shock protection function, when the instrument operator accidentally electric shock, the instrument will immediately cut off the high voltage, to ensure the safety of test personnel.

III. Testable Parameters

    The instrument can measure the following parameters and display them digitally:

        Capacitance value CX of the tested product, in pF or nF, 1nF = 1000pF.

        The dielectric loss value tgδ of the tested product is displayed in%.

IV. Technical Parameters

Accuracy:

Cx:

±(rdg×1%+1pF)

tgδ:

±(rdg×1%+0.00040)

Anti-interference index:

Frequency conversion anti-interference, the above accuracy can still be achieved under 200% interference

Electric capacity range:

Internal high voltage:

3pF~60000pF/10kV 60pF~1μF/0.5kV

External high voltage:

3pF~1.5μF/10kV 60pF~30μF/0.5kV

Resolution:

Up to 0.001pF, 4 significant digits

Range of tgδ: unlimited,

resolution 0.001%, automatic identification of three types of test samples: capacitance, inductance and resistance.

Test current range:

10μA~1A

 

Internal high voltage:

Setting voltage range:

0.5~10kV

Maximum output current:

200mA

Up and down pressure method:

continuous smooth adjustment

Test frequency:

45, 50, 55, 60, 65Hz single frequency

45/55Hz, 55/65Hz, 47.5/52.5Hz automatic double frequency conversion

Frequency accuracy:

±0.01Hz

Externally applied high voltage:

The maximum test current is 1A during positive connection, power frequency or frequency conversion 40-70Hz

Maximum test current when reverse wiring is 10kV/1A, power frequency or frequency conversion 40-70Hz

CVT self-excited low voltage output:

Output voltage 3~50V, output current 3~30A

Measuring time:

 

About 40s, related to the measuring method

Input power:

180V~270VAC, 50Hz±1%, power supply from mains or generator

Computer interface:

Standard RS232 interface

Printer:

Weihuang A7 thermal micro printer

Environment temperature:

-10℃~50

Relative humidity:

<90%

Dimensions:

460*360*350mm

Instrument weight:

28kg


Company Profile

Certifications

Filed Test & Service

Packaging & Shipping



No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher