Technical Parameters
QAS 60 Diesel generator set technical parameters | |||||
| 50Hz |
| |||
Unit Model | Unit | QAS60 |
| ||
PRP(1) | kW / kVA | 46.4kW / 58kVA |
| ||
LTP(2) | kW / kVA | 51.04kW / 63.8kVA |
| ||
Rate Speed | rpm | 1500 |
| ||
Power factor |
| 0.8 |
| ||
Voltage |
| AC 400V,3 phase 4 line |
| ||
Rated Current | A | 86.6 |
| ||
7 meters of sound pressure level | dB(A) | 69 |
| ||
Specific fuel consumption 0% load | kg/h | 2.3 |
| ||
Specific fuel consumption 50% load | kg/h | 6.3 |
| ||
Specific fuel consumption 75% load | kg/h | 8.5 |
| ||
Specific fuel consumption 100% load | kg/h | 11.6 |
| ||
Standard base fuel tank capacity | L | 149.4 | |||
Continuous full load operation time (standard) | h | 10.9 |
| ||
24 hours base fuel tank capacity | L | 414.8 | |||
Continuous full load operation time (24 h) | h | 30.4 |
| ||
Teu postures unit size shape | L×W×H(mm) | 2360*1050*1550 | |||
Working Weight | kg | 1600 | |||
24 H tank base cabinet type unit size shape | L×W×H(mm) | 2360*1050*1750 | |||
Working Weight | kg | 1900 | |||
Trailer type unit size shape | L×W×H(mm) | 3520*1760*1950 | |||
Working Weight | kg | 1950 | |||
Single step load capacity | kW | 41.8 |
| ||
Single step load capacity (ISO 8528-5:1993 G2 Standard) | kW | 41.8 |
| ||
ENGINE: | |||||
Up to standard |
| ISO 3046 / ISO 8528-2 GB/T 6072.1 & GB/T 2820.2 | |||
Manufacturer |
| Dongfeng Cummins | |||
MODEL |
| 4BTA3.9-G2 | |||
Number of Cylinders |
| 4 | |||
Air Intake Type |
| turbocharging | |||
Type of cooling |
| Water-Cooling | |||
Fuel injection way |
| Direct injection | |||
Speed Adjustment Mode |
| Electronic Governor | |||
The maximum rated power output | kW | 58 |
| ||
Coolant Volume | L | 8.3 | |||
Oil Capacity | L | 10.9 | |||
Cylinder total displacement | L | 3.9 | |||
Dc starting system | Vdc | 24 | |||
Discharge standard |
| EU II | |||
Alternator | |||||
Up to standard |
| IEC 34-1 / ISO 8528-3 | |||
Manufacturer |
| Leroy Somer | |||
MODEL |
| LSA43.2 M45 | |||
Stator/Rotor Insulation Class |
| H / H | |||
IP Grade | IP | 23 | |||
Phase digits/line number |
| 3 phase / 4 Star Connection | |||
Excitating Way |
| Synchronous brushless self-excitation | |||
Reference Conditions | |||||
Inlet pressure (Absolute Pressure) | bar | 1 | |||
Relative Air Humidity | % | 30 | |||
Air inlet Temperature | ℃ | 25 | |||
Limited Conditions | |||||
Highest use of temperature | ℃ | 50 | |||
Highest use of altitude | M | 4000 | |||
Minimum using the environment temperature | ℃ | -15(Cold start matching -25) |
Description:
(1) Commonly used power rating PRP: between the prescribed maintenance cycle and environmental conditions, varying load conditions, to the maximum power output. Generator allows 10% overload operation in 12 hours of running time 1 hour, within 24 hours running time of the average load rate, no more than the load factor of performance parameters indicated in table.
(2) Standby power rating LTP: refers to the main grid power, generator set between the prescribed maintenance cycle and environmental conditions, varying load conditions stipulated by the maximum power output. Generating set total run time not more than 500 hours a year, of which more than 300 hours continuous running time is not, and does not allow overloading. Alternator at 25 ° C ambient temperature peak power calibration.
Generating set standard: "the general technical standard diesel generating sets" international ISO8528, international electrotechnical society 34-1, IEC GB2820 in China. Diesel engine standards: international standards ISO3046 1 generating unit mobility: ISO 8528-93 is suitable for outdoor use wild took noise test with reference to the EU 2000/14 / EC OND measurement standards
Fuel Density :0.86 kg/l
The main standard:
Optional configuration of the machine:
Machinery
Battery discharge device/battery switch
Electrical class
PMG permanent magnet generator