Ammonia NH3 Gas Leak Detector for Farm Ammonia Monitor NH3 Sensor With Alarm ATEX CE
For some industrials, different farms, pig farm, poultry shed, etc, we need to test ammonia leakage or concentration.
Our Fixed ammonia gas detector can be with controller panel, it can be connected with detectors, the readings will show on the panel by 4-20mA or RS485 signal output. The Fixed ammonia Gas detector and controller panel have alarm functions, if there have any leakage or higher than alram concentration you set, it will alarm with sound and light. With relay output, once the concentration exceed the preset alarm point(threshold), it will start the acoustic-optical alarm on the central unit and drive the external equipment like exhaust fans.
Ammonia gas detector advantages
1. Employing overseas original sensor.
2. Standard equipped with three-wire system 4-20mA analog output;
relay output; RS485 output (optional)
3. Unique infrared ray control function, which can non-contacted controlthe device. Being compatible with all kinds of controlled alarms, PLC, DCS and
other control system, can be remote monitored.
4. Explosion-proof design, fast, reliable and stable.
5. Explosion-proof grade: II 2G Ex db IIC T6 Gb IP65
6. With self-calibration function and three standard keys will be used to
realize on-site maintenance.
Features
1. Monitor the Ammonia gas concentration in environment or pipeline
and alarm.
2. With self-calibration and zero calibration function,
makes the detection more accurate and reliable.
3. With temperature compensation, this is able to realize gas concentration compensation under conditions of different temperatures. Two-stage alarm with sound and light, alarm point is settable.
4. Infrared ray controller can remote control alarm point settings,
zero calibration, and address modification.
5. Can output one or two on-off signals, can drive ventilator or
solenoid valve and other external devices.
6. Working Voltage:12-36V DC
7. Case:die-cast aluminum + stainless steel (alarm light)
Technical Specification
Gas Detected |
Ammonia NH3 |
||
Detection principle |
Eletrochemistry, sensors and ic are imported from UK, fast response and high precision |
||
Install Method |
Wall-mounted, piping type, flow-type(according to the detected environment) |
||
Measure Range |
0-5, 0-20, 0-50, 0-100, 0-500, 0-1000, 0-2000, 0-3000ppm, 0-5000ppm(Ranges are Optional) |
||
Resolution |
0.001ppm, 0.01ppm, 0.1ppm, 1ppm |
||
Precision |
≤± 1%FS for high precision sensor or 3% F.S for normal sensors. |
||
Signal Output |
4-20MA, 0-5V, RS485, RS232, relay, wireless digital(optional) |
||
Response Time |
≤10S |
Recovery Time |
≤10S |
Repeatability |
≤±1% |
Linearity error |
≤±1% |
Zero shift |
≤±1%(F.S/year) |
Display |
High light nixie tube display |
Connection mode |
G1/2 external thread explosion-proof flexible pipe |
Unit |
ppm, mg/m3 |
Temperature |
-20℃~50℃ |
Humidity |
0-90%RH |
Explosion-Proof |
II 2G Ex db IIC T6 Gb IP65 |
Degree of protection |
IP65 |
Power |
12-36V DC |
Operating time |
24h |
Dimensions |
180*150*90mm |
Weight |
≤1.6kg |