Enquiries
Message
Home > Products > Other
Adopting American Agilent 5890 gas chromatographic core tech DGA-2014B Petroleum Products gas chromatography meter
  • Adopting American Agilent 5890 gas chromatographic core tech DGA-2014B Petroleum Products gas chromatography meter

Adopting American Agilent 5890 gas chromatographic core tech DGA-2014B Petroleum Products gas chromatography meter

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Warranty:
1 year
Customized support:
OEM
Place of Origin:
Chongqing, China
Brand Name:
TOP
Type:
stillation boiling range distribution detector
Supply Ability
Supply Ability:
30 Set/Sets per Month
Packaging & Delivery

Adopting American Agilent 5890 gas chromatographic core tech DGA-2014B Petroleum Products gas chromatography meter

Application

 

1. Applicable boiling range: petroleum products or distillates of 55~550℃ boiling range distribution 

such as fuel, kerosene, diesel, lubricants, wax oil etc. On this chromatographic condition tested sample components can all show the peaks. It adopts area normalization method to fix quantity. It complies to SH/T 0558-2002 and ASTM D2887standard.

2. Applicable boiling range: crude oil of initial boiling point~538℃ boiling range distribution. Get distribution proportion of fuel, diesel, kerosene, heavy oil. Since the heavy components above 538℃ can not show peak, it adopts incremental internal standard method and complies to ASTM D5307 standard.

3. Applicable boiling range: petroleum products or distillates of 55~680℃ boiling range distribution. 

On this chromatographic condition tested sample components can all show the peaks. It adopts area normalization method to fix quantity.

                           

Features

 

1. Adopts American Agilent 5890 gas chromatographic core tech; green backlight LCD screen; easy operation.

2. Temperature control upper limit max use temperature of 450℃for every instrument heating area.

3. Dual channel single column compensation; base line drift when program heat to operate FID test; ensure base line straight and chromatography peak shape perfect.

4. Adopts imported heat-resistant large aperture metal capillary column to separate; mas analysis

 use temperature of 450℃.

5. Can display and print C5-C44 n-alkanes calibration sample boiling point-time calibration curve.

6. Can provide oil sample boiling point-yield boiling range curve.

7. Can provide detailed boiling range report regarding 1% yield interval; also can provide it regarding 5℃, 10, 20, 30, 50, 100℃ boiling range.

8. Can be equipped with AS-2902 highly efficient auto liquid sample injector; auto injection 

analysis with unattended operation achieved; analysis efficiency improved and labor intensity reduced.

 

Tachnical parameters

 

Temperature control index

Oven/ Sample injector/ detector: above room temperature 5℃~450; precision ±0.1

 

Column oven parameters

Temperature control range: above room temperature 5℃~450; precision ±0.1

Program heating stages: 3 stages

Program heating speed: 0.1℃~50, increment 0.1

Program heating keeping time: 0~655 min (increment 1 min)

Big oven volume; back pullout design; program quick cooking after heating. Cooling speed: only 7min from 350 down to 60℃.

 

Injection method

Capillary split/unsplit stream injection: flash distillation injection

Packed column head injection: flash distillation injection

Can be equipped with unattended operation auto injector.

 

Hydrogen flame ionization detector (FID)

Easy disassembly and installation; convenient for cleaning and displacing nozzle; easy operation; can input signal to logarithmic amplification to reduce interference; high sensitivity, good linearity and wide range.

Limit of detection (LOD): Mt  5×10-12g/s (n-Hexadecath)

Baseline noise:  6×10-12A/H

Linearity range:  105

Stability time: < 0.5h

 

Chromatographic working station

24 bits high precision digital-to-analogue conversion (DAC)

Dual channel synchronous or asynchronous work

USB port; can be connected to external power supply; with serial port

Input voltage range: -1V~1V

Integral sensitivity: 0.05uV•s

Min solution: 1uV

Dynamic range (DR): 107

Sample frequency: Max 60 times/sec; adjustable program variables

 

 

 

 

Adopting American Agilent 5890 gas chromatographic core tech DGA-2014B Petroleum Products gas chromatography meter from China supplier

 

 

 

N-alkanes analysis spectrogram

 

 

 

Adopting American Agilent 5890 gas chromatographic core tech DGA-2014B Petroleum Products gas chromatography meter from China supplier

 

 

 

C5-C44 n-alkanes calibration sample boiling point-time calibration curve

 

Adopting American Agilent 5890 gas chromatographic core tech DGA-2014B Petroleum Products gas chromatography meter from China supplier

 

 

 

Diesel simulated distillation spectrogram

 

Adopting American Agilent 5890 gas chromatographic core tech DGA-2014B Petroleum Products gas chromatography meter from China supplier

 

 

 

 

 

You probably are looking for our flash point tester and mositure tester.

 

Adopting American Agilent 5890 gas chromatographic core tech DGA-2014B Petroleum Products gas chromatography meter from China supplierAdopting American Agilent 5890 gas chromatographic core tech DGA-2014B Petroleum Products gas chromatography meter from China supplier

 

 

 

 

 

 

 

TOP mainly supplies products as follows:

 

 

 

Our oil purifying and recycling machines:   
Series ZY Single-Stage Vacuum Transformer Oil Purifier 
Series ZYD Double High Vacuum Transformer Oil Purifier 
Series ZYB Multiply-Function insulating oil treatment machine 
Series TY Turbine Oil Purification Apparatus
Series TYA Lubricating oil/ hydraulic oil purification unit 
Series TYB Portable light Fuel oil purification machine 
Series TYD Vacuum dehydrator 
Series TYF Phosphate ester fire-resistance oil purifier 
Series PL Plate pressure oil purifier 
Series TYD Vacuum dehydrator 
Series EFD Explosion protection filtration machine 
Series BAM Press filtration system 
Series ZKCC Vacuum pumping device 
Series COP Cooking oil purification machine 
Series CYS Centrifugal oil purification machine 
Series JL Portable oil filtering and oiling machine   

 

EOR series waste engine oil recycling system

Our major testers/ analyzers: 

1.Transformer oil breakdown voltage tester ( BDV test kit) series IIJ-II

2. Acidity tester model ACD-3000I

3. Karl Fischer water content tester model TP-6A / model TP-2100

4. Moisture content tester(TPEE)

5. Fully automatic interfacial tension analyzer model IT-800

6. Gas-chromatography transformer oil gas analyzer model DGA2013-1

7. Consolidation point determinator model PT-2000

8. Kinematic viscosity tester model VST-2000

9. Flash point tester (open cup) model TPO-3000

10. Flash point tester (close cup) model TPC-3000

11. Transformer tester (CT/PT tester) model TPVA-404

12. Transformer turn ratio tester model HYG-II

13. Total base number analyzer(TBN tester) TBN-2030

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher