● Performance:
Display:
-12.1" Anti-dazzling Color TFT-LCD
-Resolution: 800×600 pixels
Battery (Option):
-Type: Rechargeable Lithium battery,11.1V/4.0AH
-Operating time under the normal use and full charge:≧150minutes
-(2 batteries for 300 minutes)
Recorder (Option):
-Method: Thermal dot array
-Paper width:50mm(1.97 in)
-Paper length:15m
-Paper Speed:12.5/25/50(mm/sec)
-Traces: Maximum 3 tracks
-Recording way: Real-time recording, Periodic recording, Alarm recording
Alarm:
-Level: Low, medium and high
-Indication: Auditory and visual
-Patient Physiological Alarm Light color: Yellow & Red:
-Equipment Technical Alarm Light color: Blue
-Supports Pitch Tone and multi-level volume;
-Supports custom arrhythmia tone
Input device:
-Touch screen (Option).
-knob: standard config
-Mouse input: Support
-Keyboard input: Support
System Output & Extensible Interfaces:
-Ethernet Network:1 Standard RJ45 socket
-Defibrillation Output:1 RJ11 socket
-Nurse Call:1 BNC socket
-Video Output:1VGA port
-USB1.1 port:4
-Auxiliary Module Rack connector.1
-SD memory card:2G (option)
-Analog Output(ECG or IBP):Option
Trend & Reviewing:
-Trend:168 hours
-NIBP measurement reviewing:1000 groups
-ARR event:128 groups of ARR event and the associated waveform
-Alarm events:128 groups of parameter alarm events and associated parameter
-Waveform at the alarm moment
Holographic waveform: The storage time depends on the stored waveforms and
the quantity of them.
Environment:
-Operating temperature:0~+40℃
-Storage temperature:-20℃ to +50℃
-Operating humisity:15%to85%(non condensing)
-Storage humidity :10% to 93%(non condensing)
-Operating atmospheric pressure:860hPa to 1060hPa
-Storage atmospheric pressure:500hPa to 1060hPa
Safety:
-IEC60601-1 Approved, CE marking according to MDD93/42/EEC
ECG:
-Lead Mode:3-leads ECG input
5-leads ECG input
12-leads ECG input
-Lead selection:Ⅰ,Ⅱ,Ⅲ
Ⅰ,Ⅱ,Ⅲ,aVR,aVL,aVF,V-
Ⅰ,Ⅱ,Ⅲ, aVR,aVL,aVF,V1~V6(option)
-Gain: 2.5mm/mV(×0.25), 5mm/mV(×0.5), 10mm/mV(×1),
20mm/mV(×2), 40mm/mV(×4),Auto
-RR: Monitor mode≧105dB
Surgery mode≦105dB
Diagnostic mode≧90dB
-Frequency response(-3d B):
Monitor mode 0.5~40Hz
Surgery mode 1~25Hz
Diagnostic mode 0.05~150Hz
-input impedance: ≧5.0Mohm
-ECG signal range:±10.0mV
-Electrode offset potential: ±500mV
-Patient Leakage Current:<10uA
-Standardizing signal:1mV±5%
-Baseline recovery:<5s after Defibrillation.(Mon or Surg mode)
-Indication of electrode separation: Every electrode(exclusive of RL)
-Protection: Breakdown Voltage 4000AVC 50/60Hz;defibrillator proof
-Sweep speed:12.5mm/s,25mm/s,50mm/s
HR:
-Range: Adult 10~300bpm
Pediatric & Neonate:10~350bpm
-Refreshing time:≦50 bpm per 2 pulses
50~120bpm per 4 pulses
≧120bpm per 6 pulses
-Resolution: 1bpm
-Accuracy:±1% or ±1bpm,whichever is greater
ST segment:
-Measurement range:-2.0mV~2.0mV
-Accuracy:-0.8mV~0.8mV: ±0.02mV or ±10% whichever is greater
Over ±0.8mV:unspecified
-Resolution:0.01mV
RESP :
-Method: Thoracic impedance
-Lead Selected from:Ⅰ(RA-LA)orⅡ(RA-LL);Default:Ⅰ
-Gain:×0.25, ×1, ×2, ×4
-Bandwidth:0.25Hz to 2.0Hz (-3dB)
-Sweep Speed: 6.25mm/s,12.5mm/s,25mm/s
-Measurement Range:0~150 rpm
-Resolution: 1rpm
-Accuracy: ±2rpm or 2% whichever is greater
-Delay of Apnea Alarm:10s,15s,25s,30s,35s,40s,45s,50s,55s,60s
NIBP :
-Way of measurement: Automatic oscillometry
-Range of measurement:
Adult: SYS 30~270mmHg
DIA 10~220mmHg
MAP 20~235mmHg
Child: SYS 30~235mmHg
DIA 10~220mmHg
MAP 20~225mmHg
Neonate: SYS 30~135mmHg
DIA 10~100mmHg
MAP 20~125mmHg
-Cuff pressure range:0~300mmHg
-Resolution:1mmHg
-Pressure Accuracy: Static:±2% or ±3mmHg,whichecer is greater
Clinical: ±5mmHg average error
Standard deviation:≦8mmHg
-Unit: mmHg, kPa
-Measurement mode: Manual, Auto, STAT
-Intervals for AUTO measurement time:1,2,3,4,5,10,15,30,60,90 minutes;
2,4,8,12hours
-STAT mode cycle time: keep 5 minutes, at 5 seconds interval.
-Overpressure Protection: Hardware and software double protections
-Pulse rate range:40~240bpm
Standard SpO2(Digital):
-Measurement Range:0~100%
-Resolution:1%
-Accuracy: At70~100%,±2%
At0~69%,unspecified
PR:
-Measurement Range:25~255bpm
-Resolution:1bpm
-Accuracy: ±1% or ±1bpm,whichever is greater
Nellcor-SpO2:
-Measurement Range:0~100%
-Resolution:1%
-Accuracy:At70~100%:±2%(Adult)
At70~100%:±3%(Neonate)
At70~100%:±2%(Low Perfusion)
At0~69%,unspecified
PR:
-Measurement Range:20~300bpm
-Resolution:1bpm
-Accuracy: 20bpm to 250bpm: ±3bpm
251bpm to 300bpm: unspecified
Masimo-SpO2:
-Measurement Range:0% to 100%
-Resolution:1%
-Accuracy: 70% to 100%:±2%(adult/pediatric,non-motion conditions)
70% to 100%:±3%(neonate,non-motion conditions)
70% to 100%:±3%(motion conditions)
0% to 69%, unspecified
-Average time:2-4s,4-6s,8s,10s,12s,14s,16s
PR:
-Measurement Range:25bpm to 240bpm
-Accuracy: ±3bpm(non-motion conditions)
±5bpm(motion conditions)
-Resolution:1bpm
TEMP :
-Max Channel: 8
-Measurement way: Thermal resistance way
-Measurement Range: 0.0℃~50.0℃(32℉~122℉)
-Accuracy: ±0.1℃ or ±1℉(exclusive of probe)
-Resolution: 0.1℃ or 1℉
-Unit: Celsius(℃),Fahrenheit(℉)
-Connecting cable: Compatible with YSI-400 serial
IBP :
- Max Channel: 8
- Measurement way: Directly invasive pressure measurement
- Sensitivity of transducer: 5uV/V/mmHg, ±2%
- Impedance of transducer: 300 to 3000Ω
- Measurement Range: -50~+350mmHg
- Resolution: 1mmHg
- Unit: mmHg, kpa, H2O
- Accuracy:
Static: ±1mmHg or ±2%, whichever is grater(exclusive of transducer)
±4mmHg or ±4%, whichever is grater(inclusion of transducer)
Dynamic: ±4mmHg or 4%, whichever is grater
Transducer sites: Arterial Pressure (ART)
Pulmonary Artery Pressure (PA)
Left Atrium Pressure (LAP)
Right Atrium Pressure (RAP)
Central Venous Pressure (CVP)
Intracranial Pressure (ICP)
P1/P2
-Selection of measurement range:
ART:0~+350mmHg
PA:-10~+120mmHg
CVP/RAP/LAP/ICP:-10~+40mmHg
P1/P2:-50~+350mmHg
EtCO2(Sidestream):
-Measure method: Infrared spectrum
-Measure Range: 0.0~13.1%(0~99.6mmHg)
-Resolution: 1mmHg
-Unit: %,mmHg,kpa
-Accuracy: 0% to 4.9%,±0.3%(±2.0mmHg)
5.0%to 13.1%,<±10%of the reading
-Measurement range of awRR:3~150rpm
-Calibration: Offset calibration:auto,manual,Gain calibration
EtCO2(Mainstream):
-Measure method: Infrared spectrum
-Warm up time: Capnogram displayed in less than 15 seconds,At an ambient
Temperature of 25℃, full specifications within 2 minutes.
-Measure Range: 0.0~19.7%(0~150mmHg)
-Resolution: 1mmHg
-Rise time(10l/min):≦60ms
-Unit: %,mmHg,kpa
-CO2 Accuracy:0-40mmHg, ±2mmHg
41-70mmHg, ±5% of reading
71-100mmHg, ±8% of reading
101-150mmHg, ±10% of reading
(at 760 mmHg,ambient temperature of 25℃)
-awRR measurement range:0~150rpm
-awRR measurement Accuracy: ±1rpm
EtCO2(Microstream):
-Measure method: Infrared spectrum
-Warm up time: Capnogram displayed in less than 20 seconds, At an ambient
Temperature of 25℃,full specifications within 2 minutes.
-Measure Range: 0.0-19.7%(0-150mmHg)
-Resolution: 1mmHg
-Unit: %,mmHg,kpa
-CO2 Accuracy: 0-40mmHg, ±2mmHg
41-70mmHg, ±5% of reading
71-100mmHg, ±8% of reading
101-150mmHg, ±10% of reading
(At 760 mmHg,ambient temperature of 25℃)
(When RR>80 rpm, all the rang is ±12% of reading)
CO2 response time: <3S
-awRR measurement range:2~150rpm
-awRR measurement Accuracy: ±1rpm
-Sample Flow Rate:50ml/min ±10ml/min
Multi Gas:
-Measure method: Infrared spectrum
-Fi and ET values: CO2 ,N2O ,O2 ,AG(HAL,ISO,NEF,SEV,DES)
-Resolution:1%
-Unit:%
-Calibration: Room air calibration automatically when changing airway
Adapter (<5 sec)
-Warm-up time:<10S,full accuracy within 1min
-Measurement and alarm range of AG
- Gas Range Accuracy
CO2 0-10% ±(0.3% ABS+4%REL)
N2O 0-100% ±(2% ABS+8%REL)
O2 10-100% ±(2% ABS+2%REL)
HAL,ISO,ENF 0-5% ±(0.15% ABS+10%REL)
SEV 0-8% ±(0.15% ABS+10%REL)
DES 0-18% ±(0.15% ABS+10%REL)
-awRR measurement range: 0~150rpm
-awRR measurement Accuracy: ±1rpm
-Rise time(flowing speed 10I/min)CO2≦90ms
O2≦300ms
N2O≦300ms
Hal,Iso,Enf,Sev,Des≦300ms
-Total system response time :<1seconds
Noninvasive Cardio Output (ICG):
Method: Measurement of thoracic electrical bioimpedanc
-Measurement Range:HR:40~250bpm
SV:5~250ml
SI:5~125ml/m2
C.O.:1.4~15L/mm
TFC:15~143KΩ
-Accuracy: HR±2bpm
SV: unspecified
C.O unspecified
-Alarm range: C.L.:0.0L/min/m2 to 15.0 L/min/m2 continuously adjustable
TFC: 10/KΩ to 150/kΩ continuously adjustable.
BIS:
-More detail please refer to BIS Specification
CO:
-More detail please refer to CO Specification
Power supply:
-Power Voltage: AC 100-240V 50/60Hz
-Power Input: ≦150VA
-Input Current:1.7~0.8V
-Safety class: Category I