Product Name | 2-Zone thermal shock test chamber | ||||||
Brand | ATMARS | ||||||
colour | Blue , white , red , customized | ||||||
MOQ | 1Pieces |
Model | AS2- | |||||||
48A | 48B | 48C | ||||||
Performance | Temperature range | -55℃ to +180℃ | -65℃ to +180℃ | -75℃ to +180℃ | ||||
Thermal shock range | -40℃ to +150℃ Hot: +60℃ to +150℃ Cold: -40℃ to -10℃ | -55℃ to +150℃ Hot: +60℃ to +150℃ Cold: -55℃ to -10℃ | -65℃ to +150℃ Hot: +60℃ to +150℃ Cold: -65℃ to -10℃ | |||||
Temperature fluctuation | ≤±0.5℃ (at a steady temperature) | |||||||
Temperature deviation | ≤±2.0℃ | |||||||
Temperature uniformity | ≤±2.0℃ | |||||||
Recovery time | ≤3min. | |||||||
Transfer time | ≤10sec. | |||||||
Temperature overshoot | ≤±2.0℃ | |||||||
Hot zone | +60℃ to +180℃ | |||||||
Preheating time | +60℃ to +180℃ in 30min. | |||||||
Cold zone | -55℃ to -10℃ | -65℃ to -10℃ | -75℃ to -10℃ | |||||
Precooling time | +20℃ to -55℃ in 45min. | +20℃ to -65℃ in 45min. | +20℃ to -75℃ in 45min. | |||||
Test room | -40℃ to +150℃ | -55℃ to +150℃ | -65℃ to +150℃ | |||||
Exposure time Test room recovery time | High temperature exposure for 30min. | |||||||
Low temperature exposure for 30min. | ||||||||
within 3min. | ||||||||
Workspace volume | 48L | |||||||
Workspace dimensions (WxDxH)mm | 400 | 400 | 400 | |||||
300 | 300 | 300 | ||||||
400 | 400 | 400 | ||||||
Exterior dimensions (WxDxH)mm | 1470 | 1470 | 1470 | |||||
1820 | 1920 | 2120 | ||||||
1930 | 1930 | 1930 | ||||||
Material | Interior | Matte SUS #304 Stainless Steel Plates | ||||||
Exterior | Powder Coated Carbon Steel Plates | |||||||
Seal | Imported Silicone Seal | |||||||
Insulation | Hard Polyurethane Foam Insulation and Glass Wool | |||||||
System | Heating | Nichrome Wire Electric Heater | ||||||
Refrigeration | German GEA Cascade Semi-Hermetic Compressors or Other Brands Air-cooled or Water-cooled Cooling Mode for Option Zero Ozone Depletion Potential (ODP) Refrigerant - R404A / R23 | |||||||
Controller | Display Operating mode Memory capacity Control tolerance Temperature sensor input Communication interface | 7 inch 65535 true color, LED backlit display screen, resolution 800 x 480; Program and setpoint operating mode; Program capacity up to 127 programs, each 999 hours, maxiumum 32,000 cycles; Temperature measuring range: -90.00℃ to 200.00℃, tolerance: ±0.20℃; Supports multiple sensor inputs such as T type, PT100; Comes with USB interface, supports RS-485, LAN and others. | ||||||
Noise level | ≤70dB | |||||||
Allowable ambient conditions | Temperature: +5℃ to +35℃; Relative humidity: ≤85%RH (No condensation); Air pressure: 86kPa to 106kPa | |||||||
Electrical supply | AC 380 (1±10%)V (50±0.5)Hz 3 Phase 4 Wire plus Earth Wire | |||||||
▲Custom options available |