2 RCD is given priority to switch the consumer units | ||||||
Product model | Main switch configuration | Available loop element | ||||
Residual Current Protective Device | Quantity | |||||
AOX-07M/L2 | AOL-100 80A 30mA 2P | 2 | 3 | |||
AOX-10M/L2 | AOL-100 80A 30mA 2P | 2 | 6 | |||
AOX-13M/L2 | AOL-100 80A 30mA 2P | 2 | 9 | |||
AOX-16M/L2 | AOL-100 80A 30mA 2P | 2 | 12 | |||
AOX-21M/L2 | AOL-100 80A 30mA 2P | 2 | 17 |
Optional matching circuit protection products | ||||
Product Name | Product Model | Current Specification | ||
Isolating Switch(QS) | AOH-125 | 25A、40A、63A、80A、100A | ||
Residual Current Circuit Break(RCD) | AOL-100 | 40A、63A、80A、100A | ||
Mini Circuit Breaker(MCB) | AON-63 | 2A、4A、6A、10A、16A、20A、25A、32A、40A、50A、63A | ||
Surge Protection Device(SPD) | AOU-65 | Max Discharge Current 65kA Max. Permissible Strength of Backup Fuse 125A gL |
Product Model | Circuit Unit | Width(B) | Mounting Dimension (E) |
AOX-07M | 07 | 188 | 138 |
AOX-10M | 10 | 241 | 160 |
AOX-13M | 13 | 292 | 210 |
AOX-16M | 16 | 343 | 260.4 |
AOX-21M | 21 | 438 | 356 |