Tekna series
Easy to selection, standard configuration: PVDF pump head
Only five models for all flow range, set all functions of electronic metering pumps in one. Every model use PVDF pump head.
Standard Configuration: PVDF pump head and ceramic ball valve
The diaphragm has been tested over a period of 5 years.
Pumps can steady operation in range from 100 to 240 Vac.
Include foot filter, injection valve, fixing bracket, suction tube and delivery tube.
AKS | analog | manual adjustable |
AKL | manual adjustable, with liquid probe interfaces | |
APG | manual adjustable proportional flow rate: external analog signals (4-20mA) or external digital signal (water meter), with liquid probe interfaces | |
TPG | digital | manual adjustable proportional flow rate: external analog signals (4-20mA) or external digital signal (water meter), with liquid probe interfaces |
TPR | manual adjustable, proportional flow rate: built-in PH/ORP monitor controller |
Model | Pressure (Bar) | Flow Rate (L/H) | Connections In/Out(mm) | Max frequency (stroke/min) | Power (Watt) | GW (Kg) | Packing size L*W*H(mm) |
20 | 0.4 | 4 / 7discharge | 120 | 15 | 4.1 | 298*195*250 | |
16 | 0.8 | ||||||
10 | 1.2 | ||||||
6 | 1.5 | ||||||
20 | 2.5 | 4 / 6 inhale 4 / 7discharge | 120 | 20 | 4.3 | ||
18 | 3 | ||||||
14 | 4.2 | ||||||
8 | 7 | ||||||
12 | 4 | 4 / 6 | 160 | 20 | 4.3 | ||
10 | 5 | ||||||
8 | 6 | ||||||
2 | 8 | ||||||
16 | 7 | 4 / 6 | 300 | 40 | 4.3 | ||
10 | 10 | ||||||
5 | 15 | ||||||
1 | 18 | ||||||
5 | 20 | 8 / 12 | 300 | 40 | 4.3 | ||
4 | 15 | ||||||
2 | 38 | ||||||
0.1 | 54 |