AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3
  • AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3

AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Warranty:
1 year
Customized support:
OEM, ODM, OBM
Place of Origin:
Guangdong, China
Brand Name:
Vilva
Model Number:
VILVA-RCD
Power:
Electronic
Product name:
RCD Load Bank
Color:
Grey/Orange/White/Black
Material:
resistor (R), capacitor (C) and diode (D)
Rated Power:
0-400KW
Rated Voltage:
AC110~277V,AC380~480V
Load Tolerance:
≤±5%
Control power:
AC110~277V,AC380~480V
Power factor:
0.7~1.0
Type:
Indoor/Outdoor type
Application:
UPS testing
Certification:
CE
Supply Ability
Supply Ability:
20 Set/Sets per Month
Packaging & Delivery
Customized UPS testing load 20KVA RCD non-linear simulated load
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
Product Description
1.Main application:
Non-linear load: RCD load is a kind of non-linear simulate load, used to test UPS power supply,inverter power supply, etc., to understand its real working ability with non-linear loads such as computers and network equipment. With the development of digitalization and networking in today's society, rectifying loads such as computers and network equipment are used in large numbers. The load formed by these rectifying filter circuits has non-linear characteristics, and its resistance value is not constant, has higher requirements on the output range and stability of the power supply equipment. Therefore, for network UPS power supply, inverter power supply and other power supply equipment, analog loads with nonlinear characteristics must be used to debug and test their crest factor and other parameters.
2.Main advantages:
a. Non-linear load RCD load is composed of resistor (R), capacitor (C) and diode (D),Resistive load adopt new type of consumption components,Resistance thermal shrinkage and sealing installed in stainless steel tube, steel tube with insulation radiator, good moisture and corrosion resistance,good heat dissipation, high insulation, safe and reliable. High power density of resistance elements,3-phase current balance, no red heat phenomenon, Capacitive load capacitance,working time is more than 6000 hours.
b.The fan adopts a small axial fan, with large wind volume, good heat dissipation, low noise and other characteristics.

3.Standard:
According to GB/T 7260.3-2003 "Uninterruptible Power Supply (UPS) Part 3: Methods for Determining Performance and Test Requirements" and other relevant national standards, or IEC 62040-3 Annex E, through in-depth research and development and testing, the RCD load is determined Design specifications and parameter standards, and developed a new type of RCD simulation load. The circuit principle is shown in the figure below:
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
Product Paramenters
Model
Rated power
Rated voltage
Power factor
Adjustment accuracy
Display mode
Dimension
W*D*H(mm)
VILVA-5KW-RCD
5KW


1 Phase 
50HZ/60HZ

 AC110V
AC220V
AC230V
AC240V 




3 phase
50HZ/60HZ 

AC220V
AC380V
AC400V
AC415V
AC440V
AC480V






Adjutable:

Pf=0.7~1 




Fixed Pf 

  Pf=0.7          Pf=0.8   
  Pf=0.9
100W









Real-time display 

voltage (V)
 current (A) frequency (HZ) 
Power(KW/KVA)
Power factor
600*750*980
VILVA-10KW-RCD
10KW

100W
600*750*980
VILVA-20KW-RCD
20KW

100W
600*750*1110
VILVA-30KW-RCD
30KW

100W
600*750*1332
VILVA-40KW-RCD
40KW

100W
600*750*1332
VILVA-50KW-RCD
50KW

100W
600*750*1332
VILVA-60KW-RCD
60KW

100W
600*1000*1332
VILVA-80KW-RCD
80KW

100W
600*1000*1554
VILVA-100KW-RCD
100KW

1KW
800*900*1750
VILVA-120KW-RCD
120KW

1KW
900*1000*1750
VILVA-150KW-RCD
150KW

1KW
Customerlized
VILVA-200KW-RCD
200KW

1KW
Customerlized
VILVA-250KW-RCD
250KW

1KW
Customerlized
VILVA-300KW-RCD
300KW

1KW
Customerlized
VILVA-400KW-RCD
400KW

1KW
Customerlized
VILVA-500KW-RCD
500KW

1KW
Customerlized
Note:above mode may customerlized,please contact us!
General parameter
Load type
RCD Load:Resistor / Capacitor/ Diode rectifier
Protect Function
Short circuit/over voltage/over current/over temperature protection, over temperature alarm
Control mode
Local Manual control:Contactor or MCB
Cooling mode
Forced air cooling
Moving mode
4 wheels for easy moving&Forklift
Optional function
 Manual control with Remote control box / Remote control with software (RS485)
Related Products& Cases
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
1500KW Load bank shipping to Brune

AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
Yuchai 2*500KW Load Bank for Generator test
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
Huawei AC10.5KV 2600KW Load bank

AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
Our Company
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
Shenzhen Vilva Electronic Co.,Ltd
    Established on 2010,specializing in R&D, manufacturing and service of Load bank over 10 years,and is high-tech enterprise.
    Passed IS09001:2008 quality management system and CE certification, etc.
    Working closely with worldwide brands,like Huawei,ZTE,BYD,Yuchai,ABB,OMRON,KSTAR,EMERSON,INVT etc. 
Our Factory
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
Certifications&Exhibition
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier
FAQ
1.May the load bank be customized ? Yes,all product may be customized. 2.Are you a factory or a trading company? We are factory,specializing in R&D, manufacturing and service of Load bank over 10 years 3.Do you have this load bank in stock? Usually all load bank are customized ,but some standard load bank in stock. 4.How about the lead time ? About 35-58 days 5.Which port is closely with your factory ? Shenzhen Port & Guangzhou port 6. What kind of load in this load bank? Usually,combine the laod of Resistive/ Inductive/capacitive. 7. Can the Load Bank test at single phase? Yes, but the rating available is 1/3 of the rated testing capacity. 8. Indoor type or outdoor type? Standard indoor type isn't weatherproof, but optional outdoor type with air duct to enable weatherproof.
Packing & Delivery
AC230V 20kVA RCD Load Bank With High Quality Non-linear load bank for UPS testing as per IEC 62040-3 from China supplier

Contact information:

Amy
Shenzhen Vilva Electronic Co.,LTD
Email: Amy@vilva-test.com | Skype/WhatsApp:+86-15814356357
Tel:+86-18122867790 | Office:+86-0769-83036636-6053
Add: 2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C
No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher