4585Z | Parameter |
Backset | 45mm |
Center distance | 85mm |
Fire test-Timber fire door | 111 mins |
Fire test- Steel fire door | 260 mins |
CE certificate (Intertek) | 3 X 9 1 0 G 3 B C 2 0 |
Intended Use | Yes/No | Comments | Reference |
On hinged doors | Yes | Locks are tested for side force and end force | EN12209:2016 |
Supported lock application | Yes | Tested in accordance with 5.5.1 and 5.11.3 using the fixture 20 or 29 and/or 5.11.5 using fixture 32 with support | |
Suitability for use on smoke control /fire resistance doorset | Yes | See manufacturers declaration referring to a test according to EN 1634–1 or declaration of melting point of the relevant latching parts and if applicable the duration of the proven smoke control and/or fire resistance | |
Lock for use with unsprung handle | Yes | The lock shall conform to 5.4.6, minimum follower restoring torque of 0,8 Nm |