PIP-8048LC is a 8000W 48V 60A Pure Sine Wave inverter charger off grid inverter featuring:
PIP-LC SERIES | 4024 | 6048 | 8048 | 11048 |
ELECTRICAL SPECIFICATIONS | ||||
Continuous/Surge Output | 4/8KW | 6/12KW | 8/16KW | 11/14.5KW |
Input Voltage Range | 60~135V or 120~270VAC (120 or 230V) | 120~270VAC (230V only) | ||
Output Voltage | 110/115/120Vac or 220/230/240VAC (programmable) | 220/230/240VAC | ||
Output Waveform | Pure Sine Wave | |||
Output Frequency | 50Hz or 60Hz (auto sensing 45Hz~70Hz) | |||
Output Regulation | < 3% RMS for battery voltage range | |||
Peak Efficiency | 90% (with Green Power Mode) | |||
Input VDC / Range | 24V: 20~29.3V | 48V: 40~58.5V | ||
Transfer Time | < 8ms | |||
Recharging Current | >60A | >85A | ||
PROTECTIONS | ||||
Batt. Reverse Polarity | By Fuse | |||
Overload (UPS/Batt. Mode) | > 110%: Pre-Alarm, Amber LED Blinking / >110~150% for 30 sec, > 150% for 200ms Shutdown | |||
Over Temperature | > 60°C Pre-Alarm | |||
Low Batt (Alarm/Shutdown) | <21.5V / <20V | <42.5V / <40V | ||
Short Circuit | Circuit (UPS Mode) / Electronic Circuit (Battery Mode) | |||
LED Indicator | Green: Power, Amber: Warning, Red: Fault | |||
LCD Display | UPS Status, Input / Output Voltage Frequency, Load, Battery Voltage, Battery Capacity, Temperature | |||
ENVIRONMENTAL / MECHANICAL SPECIFICATIONS | ||||
Certification / EMC | CE / EN62040-1-1, EN62040-2 | |||
Operating/Storage Temp. | 0°C ~ +40°C / -20°C~ +70°C | |||
Operating Humidity | 20~90%RH Non-Condensing | |||
Dimension | 415*600*260mm | 452*670*277mm | ||
Weight | 50Kg | 52Kg | 54kg | 110kg |
*NOTE: Product photos shown below are the smaller 1.6kw/2.4kw 24V models for illustrative purpose only; actual item has larger housing but same design & color