Item | Value | ||
Model | XW-BST5V50mA | ||
Applicable Industries | Manufacturing Plant, Food & Beverage Factory | ||
Input Power | AC 110/220V ±10% / 50Hz | ||
Resolution | AD:16bit;DA:16bit | ||
Input Resistance | ≥1MΩ | ||
Input Power | 40 W | ||
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure | ||
Channel Control Mode | Independent Control | ||
Voltage | Per Channel Voltage Range | Charge:0.025V~5V;Discharge:0.025V~5V | |
Accuracy | ±(0.1%FS+0.1%RD) | ||
Resolution | 0.003%FS(Full Range) | ||
Stability | ≤0.03% | ||
Current | Per Channel Current Range | Charge:0.1mA~50mA;Discharge; 0.1mA~50mA | |
Accuracy | ±(0.1%FS+0.1%RD) | ||
Resolution | 0.003%FS(Full Range) | ||
Stability | ≤0.03% | ||
Time | Rise Time | The Current 10%-80% Hardware Response Time is 1ms | |
Step Time | 1s≤Single Step Time Range≤365*24 h, Time Form Support 00:00:00(h、min、s) | ||
Aux Channel | Aux Input | Temperature, Voltage | |
Temperature | -25℃~40℃ | ||
Temperature Accuracy | ±2℃ | ||
Temperature Resolution | 0.1℃ | ||
Voltage Accuracy | ±0.1% of FS | ||
Charge | Charge Mode | Constant Current Charge、Constant Voltage Charge、 Constant Current and Constant Voltage、 Charge Constant Power Charge | |
End Condition | Voltage、Current、Relative Time、Capacity、-△V | ||
Aux Temperature, Voltage | |||
Discharge | Discharge Mode | Constant Current Discharge、Constant Power Discharge、Constant Resistance discharge | |
End Condition | Voltage、Current、Relative Time、Capacity、-△V | ||
Pulse | Charge | CCC,CPC | |
Discharge | CCD,CPD | ||
Minimum Pulse Width | 500ms | ||
Pulse | 32 pulse setting in one step | ||
Automated Switch | Automated switch from charge to discharge for each pulse | ||
Cycle | Loop Measure Range | 1~65535 times | |
Max Steps Per Loop | 254 | ||
Nested Loop | Max three levels of loops | ||
Protection | Software Protection | Power-down Data Protection | |
Off-line Testing Function | |||
Setting Protection Condition,Setting Parameter:Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time | |||
Hardware Protection | Additional Anti-reverse Protection Model | ||
Voltage and Current Testing Sample | 4-wire connecting | ||
Noise | <85dB | ||
Database | MySQL Database | ||
A Means of Communication of Upper Machine | TCP/IP Protocol | ||
Data Output | EXCEL、TXT、Graph | ||
Communication Interface | Ethernet Port | ||
Per Unit Main Channels No. | 8 | ||
Dimensions(L*W*H) | 480*380*130 mm | ||
Weight | 18 kg | ||
Accessory | Main Machine | Battery Analyzer | |
Ethernet Cable | For connecting the main machine to the computer (need switch below) | ||
Software | BST Server and Client Software | ||
Alligator | For connecting battery (Larger clip for current and small clip for voltage) | ||
Switch | For connecting analyzer and computer | ||
Power Cable | AC wall outlet to equipment |