600/1000V 3 core, 4 core XLPE Insulated armoured 10 16 25 35 50 sq mm copper cable
Standard
IEC 60502
Application
0.6/1kV PVC/XLPE insulation 50 sq mm copper cable is used for fixed installations of rated voltages 1kV and below, such as distrubution networks or industrial installations.
Product Description
1) Rated Voltage: 0.6/1kV
2) Max. working temperature: 70°c (pvc insulation), 90°c (xlpe insulation)
3) Max. temperature during short circuit (≤5S): 160°c (pvc insulation), 250°c (xlpe insulation)
4) Conductor: stranded copper
5) Shape of conductor: circular
6) Sectional area: 50mm2
7) Insulation: PVC/XLPE
8) No. of cores: 1, 2, 3, 3+1, 3+2, 4, 4+1, 5
9) Armor: steel tape or steel wire available
10) Oversheath: PVC
11) Min. beding radius: 15 times cable radius for single-core cables and 12 times for multi-core ones
12) Max. conductor DC resistance at 20°c: 0.387Ω/km
1.PVC copper Cable:
Cu(Al)/PVC/PVC,Cu(AL)/PVC/SWA/PVC,Cu(Al)/PVC/STA/PVC copper Cable
TYPE | Description of Cable | Main Applications | |
CU core | AL core | ||
VV | VLV | Copper/Aluminium core,PVC insulated,PVC sheathed copper cable | Non-armoured PVC cable are suited for laying indoors,In cable trench,On cable racks and in pipes. Unable bear external pressures and tensions. |
VV22 | VLV22 | Copper/Aluminium core,PVC insulated,steel tape armored,PVC sheathed copper cable | Steel-tape armoured PVC cables are suited for vertical burial.Can bear moderate positive pressures,Unable bear tension forces. |
VV23 | VLV23 | Copper/Aluminium core,PVC insulated,steel tape armored,PE sheathed copper cable | |
VV32 | VLV32 | Copper/Aluminium core,PVC insulated,thin steel wire armored,PVC sheathed copper cable | Thin steel wire armoured PVC cables are used in case of great difference of levels or vertical installation and Can do vertical burial.Can bear moderate positive pressures and tension forces. |
2.XLPE copper Cable:
Cu(Al)/XLPE/PVC,Cu(AL)/XLPE/SWA/PVC,Cu(Al)/XLPE/STA/PVC copper Cable
YJV | YJLV | XLPE insulation PVC sheath copper cable (Cu/XLPE/PVC) | To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn't bear mechanical force outside |
YJV22 | YJLV22 | XLPE insulation, steel tape armor, PVC sheath copper cable | To be laid underground, the cable could bear certain mechanical force, but it couldn't bear great pulling force. |
(Cu/XLPE/PVC/STA/PVC) | |||
YJV23 | YJLV23 | XLPE insulation, steel tape armor, PE sheath copper cable | |
(Cu/XLPE/PVC/STA/PE) | |||
YJV32 | YJLV32 | XLPE insulation, thin steel-wire armor, PVC sheath copper cable | Be applicable to the well, water inside and fall in the bad soil, the cable cans bear the equal dint outside the machine with pull the dint |
(Cu/XLPE/PVC/SWA/PVC) | . |
3.Number of core:1 core to 5cores.
1 core | 1*10; 1*16; 1*25; 1*35; 1*50; 1*70; 1*95; 1*120; 1*150; 1*185; 1*240; 1*300; 1*400 |
2 core |
2*1.5; 2*2.5; 2*4; 2*6; 2*10; 2*16; 2*25; 2*35; 2*50; 2*70; 2*95; 2*120; 2*150; 2*185; 2*240; 2*300 |
3 core |
3*1.5; 3*2.5; 3*4; 3*6; 3*10; 3*16; 3*25; 3*35; 3*50; 3*70; 3*95; 3*120; 3*150; 3*185; 3*240; 3*300 |
4 core | 4*4; 4*6; 4*10; 4*16; 4*25; 4*35; 4*50; 4*70; 4*95; 4*120; 4*150; 4*185; 4*240 |
5 core |
5*1.5; 5*2.5; 5*4; 5*6; 5*10; 5*16; 5*25; 5*35; 5*50; 5*70; 5*95; 5*120; 5*150; 5*185; 5*240; |
3+1 core | 3*4+1*2.5; 3*6+1*4; 3*10+1*6; 3*16+1*10; 3*25+1*16; 3*35+1*16; 3*50+1*25; 3*70+1*35. |
4+1 core |
4*2.5+1*1.5; 4*4+1*2.5; 4*6+1*4; 3*10+1*6; 4*16+1*10; 4*25+1*16; 4*35+1*16; 4*50+1*25; 4*70+1*35; |
4.Rated voltage U0/U 0.6/1KV. 1.8/3kV 3.6/6kV 6/6kV 6/10kV8.7/10kV8.7/15kV,12/20kV,19/33KV,21/35kV,26/35kV ETC
The copper cable is manufactured according to GB/T 12706-2002 or IEC 60502-1997.It is suitable to be installed in the four wires system with rated voltage of 220KV And Below for transmiting electricity.
600/1000V 3 core, 4 core XLPE Insulated armoured 10 16 25 35 50 sq mm copper cable
WHATAPP 0086 13803890503
...