Enquiries
Message
Home > Products > Other
50Hz 60Hz 55KW wind turbine inverter dc ac solar power inverter 50kw 60KW 3 phase pure sine wave inverter circuit diagram
  • 50Hz 60Hz 55KW wind turbine inverter dc ac solar power inverter 50kw 60KW 3 phase pure sine wave inverter circuit diagram

50Hz 60Hz 55KW wind turbine inverter dc ac solar power inverter 50kw 60KW 3 phase pure sine wave inverter circuit diagram

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
XD
Model Number:
HDSX
Type:
DC/AC Inverters
Output Type:
3Phase
Output Current:
0~45A selectable
Output Frequency:
50Hz±0.5%
Size:
775*635*1400mm
Weight:
350kg
Certificate:
CE RoHS
Output Voltage:
380V±1%
Output waveform:
Pure sine wave
Mains supply:
charge for battery
Display:
LCD
Phase:
Single Phase
AVR Function:
Yes
AC output socket:
Universal AC socket
Packaging Details:
Standard export carton packing
Service:
OEM Service Offered Design Service Offered Buyer Label Offered
Product name:
50 60Hz 55KW wind turbine inverter dc ac solar power inverter 50kw
Supply Ability
Supply Ability:
10000 Piece/Pieces per Month
Packaging & Delivery
Product Description
  Exclusive Feature 

 

1. 100% unbalance loads design.

2. Low frequency, pure sine wave output.

3. Wide AC voltage input range, AVR output.

4. Peak power more than 3 times.

5. LCD display for all working datas.

6. AC prior/EC mode/Battery prior selectable.

7. AC charge current 0~45A selectable.

8. Seven battery type selectable.

9. 50Hz/60Hz automatic recognition.

10. Support diesel/gasoline generator input.

11. RS232/RS485/APP/SNMP/GSM communication port optional.

 

  Product Details 

 

To be added……

 

 

 

  Technical parameter

 

Specification
Model HDSX 503384 603384
Rated Power 50KW 60KW
Battery Voltage 384VDC 384VDC
N.W.(kg) 326 398
G.W.(kg) 350 422
Size(L*W*Hmm) 715*575*1275
Packing Size(L*W*Hmm) 775*635*1400
Parameter
Input Battery Input Voltage Range 168V~240V for 192V system; 336V~480V for 384V system
AC Input Voltage Range 380Vac/400Vac±10%(customized 190Vac/200Vac)
AC Input Frequency Range 45Hz-65Hz
Phase 3/N/PE
Output Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 380Vac/400Vac±10%(customized 190Vac/200Vac)
Output Frequency(Battery Mode) 50/60Hz ±1%
Output Wave(Battery Mode) Pure Sine Wave
Output waveform distortion Linear load≤3%
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Conforming to AC input
Output Frequency(AC Mode) Conforming to AC input
Phase 3/N/PE
AC charger AC charging current 0~45A selectable
AC charging method Three-stage(constant current, constant voltage, floating charge)
Battery type
(Optional)
U0: Gel U.S.A Charge Voltage: 224V for 192V system, 448V for 384V system;
Float Voltage: 219.2V for 192V system, 438.4V for 384V system.
U1: A.G.M.1 Charge Voltage: 225.6V for 192V system, 451.2V for 384V system;
Float Voltage: 214.4V for 192V system, 428.8V for 384V system.
U2: A.G.M.2 Charge Voltage: 233.6V for 192V system, 467.2V for 384V system;
Float Voltage: 219.2V for 192V system, 438.4V for 384V system.
U3: Sealed lead Acid Charge Voltage: 230.4V for 192V system, 460.8V for 384V system;
Float Voltage: 217.6V for 192V system, 435.2V for 384V system.
U4: Gel European Charge Voltage: 230.4V for 192V system, 460.8V for 384V system;
Float Voltage: 220.8V for 192V system, 441.6V for 384V system.
U5: Open lead Acid Charge Voltage: 236.8V for 192V system, 477.2V for 384V system;
Float Voltage: 216V for 192V system, 432V for 384V system.
U6: Calcuim(open) Charge Voltage: 241.6V for 192V system, 483.2V for 384V system;
Float Voltage: 217.6V for 192V system, 435.2V for 384V system.
U7: Sulphation cycle 15.5V for 4hrs 
customize battery Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.) can be customized according to user requirements.
Working Mode(Selectable) AC prior(d1) Under AC prior mode, device will always use utility source and through regulator to supply loads as well as charge battery(charging current selectable); when utility power is with high/low/serious distortion or other abnormal, device will auto converter battery source to supply loads.
EC mode(d2) Under Energy saving mode, device dedects load, when the load is <10% rated power, device will auto on/off AC output; when the load is > 10% rated power, device will start AC output.
Battery prior(d3) Under Battery prior mode, device will always use battery source to coverter high quality electricity for load; when battery source is failed, device will auto use utility source and through regulator to supply loads.
Protection Battery low voltage alarm 176V for 192V system, 352V for 384V system
Battery low voltage protection 168V for 192V system, 336V for 384V system
Battery high voltage alarm 240V for 192V system, 480V for 384V system
Battery high voltage protection 272V for 192V system, 544V for 384V system
Battery high voltage recover 232V for 192V system, 464V for 384V system
Overload protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Transfer Time ≤4ms
Display LCD
Thermal method Cooling fan in intelligent control
Communication RS232/RS485/APP/SNMP/GSM(Optional)
Environment Operating temperature  -10℃~40℃
Storage temperature -15℃~60℃
Noise 2000m(More than derating)
Elevation ≤65dB
Humidity 0%~95% ,No condensation
Note: All specifications are subject to change without prior notice

 

  How to Use the Solar Inverter?

 

1. Battery number and capacity should be configured according to the rated voltage of the solar power system or inverter;

2. We offer 3 optional working modes:

01 Grid priority mode: When the grid and battery are connected to the inverter, grid will supply power to the loads directly after voltage being stabilized and charge batteries via inverter. When the grid is cut off, the battery will automatically continue to supply power via inverter.
02 Energy saving mode: If the power of the connected AC loads is lower than 5% of the inverter’s rated power, there will be no output from the inverter. Only the chip of inverter is working. The power consumption of the inverter is only 1~6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%, within 5S the inverter will automatically convert DC to AC to supply power for the loads . The LCD shows the output voltage.
03 Battery priority mode: When the grid and battery are connected to the inverter, battery will supply power to the loads first. When battery capacity is not enough, the grid will continue to supply power automatically.

 

  Practical Application

 

Packaging & Shipping
  Packaging & Shipping

Package
Carton Box for packaging, or Wooden Box advised for Samples to protect in transportations.

Shipping
1. Fedex/ DHL/ TNT/ UPS for samples, door-to-door.
2. By air or by sea for batch goods, for CFL, Air port/ Port receiving.
3. Customers specifying freight forwarders or negotiable shipping methords.
4. Delivery time: 7 days for samples; 10 to 25 days for batch goods.

 

 

  Payment Term

 

T/T EXW 30% T/T in advance, balance paid before dispatch
FOB
CNF(CFR) 30% T/T in advance, balance paid against copy of B/L
CIF
L/C, D/A, D/P, Money Gram, Western Union, Paypal (Optional)

 

Related Products
50Hz 60Hz 55KW wind turbine inverter dc ac solar power inverter 50kw 60KW 3 phase pure sine wave inverter circuit diagram from China supplier
Company Information
  Why Choose Xindun Power? 

 

  About us 

 

Guangdong Xindun Power Technology Co.,Ltd

Factory Location

Foshan,Guangdong,China

Industry Experience

13-year manufacturer, 16-year trading, 8-year alibaba gold supplier

Product Range

solar inverter, hybrid inverter, ups, solar charge controller, solar power system, mini solar dc system
Main Market Africa, Middle East, Asia & South America. (Ukraine, Russia, Vietnam, Pakistan, Nigeria, Kenya, South Afriac, Ghana, Thailand, Philippines, etc.)
Factory 6000 Square Meters, 60+ workers
Department R&D, Production,  Sales, Marketing, Purchasing, QA, After-sale service department
Certificate ISO9001:2015, CE, IEC, etc.
Patent Software Paten, Design Patent, Project Pantent

 

 

  Workshop

  

  Production Process

 

 

  EXHIBITION & CUSTOMER

  

 

 

  CREDIBILITY

 

FAQ
  FAQ 

 

A: Are your inverters pure sine wave output?

Q: A Yes, All are true pure sine wave.

 

A: What kind of output you can do?

Q: Normally we produce inverter with 110V 115V 120V 220V 230V 240V, 50/60Hz self-adaption. If you have special requirements, please tell us for engineer consulting.

 

A: What' s the difference between low frequency and high frequency inverter?

Q: Low frequency inverter has various protections, strong ability to adapt to the environment. more reliable, with voltage regulation.

 

A: What's the difference between pure sine wave inverter and modified sine wave inverter?

Q: Pure sine wave output inverter is just as good as the Public power grid. Even better. Low repaired rate, long lifespan, Without harmonic pollution,  enviromental-friendly and appliances protected.

Modified sine wave output has a negative impact on appliances and can't load inductive load, such as air contition, refrigerator and etc. Certain motor control circuits don't like the modified wave.

 

A: What appliances your inverters can load?

Q: Our inverter can be used in household, Office, agricultural appliances and other inductive load such as refrigerator, air conditioner, water pump, etc.

 

A: Can you print our company logo on inverters, nameplates and packaging?

Q: Yes, we accept OEM orders.

 

A: How to choose a right inverter?

Q: Tell us your demand, then our sales will recommend a suitable inverter to you.

 

A: How to solve the technical problem?

Q: 24 hours after-service consultancy just for you and to make your problem to solveeasily.

 

A: Do I Need A Power Inverter?

Q: Actually, no. This is the only component of a solar energy system that is not absolutely required. However, if you don't use one, you will not have 220 or 230 volts AC and will have use battery power alone. This might be acceptable in a small RV or cabin, but most people want to use normal AC appliances.

 

A: What's The Difference Between 12, 24, And 48 Volt Inverters?

Q: This refers to the input voltage from the battery bank. The main consideration is that at higher voltages the current is less so that you can use smaller wires between your solar panel array and your battery bank. Of course, when you decide on a system voltage, the Solar Panels, Inverter, and Battery Bank all need to use the same voltage.

 

A: What to do if the product is broken? 

Q: If any product is faulty, you can send the picture or video to us, we sill study it and supply the spare parts of PCB board free for after sale service.

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher