Water machine -500Liter per hour | ||||||
Inlet flow: | ≥0.75m3/h | Outlet flow: | 500L per hour | |||
Inlet pressure: | ≥2KG | Recovery rate: | 60-75% | |||
Raw water Conductivity: | ≤450us/cm | Desalination rate: | 98% | |||
RO output Conductivity: | ≤10us/cm | Power:(220V,60hz,1 phase) | 1.85kw | |||
Control model: | Automatic |
Every part of the reverse osmosis system | ||||||
S/N. | Commodity name | Application | Remark | |||
1 | Raw water tank | Store water, buffering pressure, overcome instability of supplying water by pipe, ensure to supply water stably and continuously for whole system | Customer provide for themselves, because big size will result in expensive freight. | |||
2 | Raw water pump or called booster pump | Provide needed pressure for every pretreatment filter | We can provide CNP pumps or Grundfos pumps | |||
3 | Mechanical filter or called quartz sand filter or sand filter | We use fiber glass or stainless steel vessel as housing, fill quarts sand, it can filter big particles impurities, suspended substances, colloids etc. | ||||
4 | Activated carbon filter | We use fiber glass or stainless steel vessel as housing, fill activated carbon, remove color, odor, residual chlorine and organics substances. | ||||
5 | Water softener, demineralizer, or called Na+ exchanger | Adopt cation resin to soften water, cation resin will absorb Ca2+, Mg2+(main elements for composing scale), reduce hardness of raw water, System can make resin intelligently regenerate, recycling | ||||
6 | Security filter or pp filter, or called PP sediment filter | prevent large particles, bacteria, viruses into RO membrane, accuracy is 5µm, | ||||
7 | High pressure pump | Provide needed working pressure for RO system, ensure production capacity of pure water. | CNP pump, Grundfos optional | |||
8 | RO(reverse osmosis) system | Can remove particles, colloids, organic impurities, heavy metal ions, bacteria, virus, heat source etc. harmful substances and 99% dissolved salts. | RO membranes USA Filmtec D |