Filter Material | ||||||||
Nylon/PTFE/PTFE L/PES/PVDF/MCE/CA/GF/PP/Activated Carbon | ||||||||
Pore Size | ||||||||
0.1μm | 0.22μm | 0.45μm | 0.65μm | >1.0μm | ||||
Mycoplasmas Colloids Small Particulates | UHPLC Bacteria Small Particulates | HPLC Particulates | Yeasts Particulates | Large Particulates | ||||
Process Volume | ||||||||
Process Volume | 1-10ml | 10-60ml | 10-80ml | 10-100ml | ||||
Syringe Filter Diameter | 13mm | 20mm | 25mm | 33mm |
Classification | FILTSTAR™ | Winstar™ | ||||||||||
Filter Media | Media Nylon/PTFE/PTFE L/PES/PVDF/MCE/CA/GF/PP/Activated Carbon | Nylon /PTFE /PES /PTFEL/ PVDF/ PVDF L | ||||||||||
Pore Size, μm | 0.1μm, 0.22μm, 0.45μm, 0.65μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm, 10μm | 0.22μm, 0.45μm | ||||||||||
Pre-filter | 1um Glass Fiber or PP | Non | ||||||||||
Housing | PP | PP | ||||||||||
Diameter | 4mm | 13mm | 25mm | 33mm | 50mm | 13mm | 25mm | |||||
Filtration Area | 0.2cm² | 1.3cm² | 4.9cm² | 8.5cm² | 19.8cm² | 1.0cm² | 4.3cm² | |||||
Maximum Operating Pressure | 5.2bar | 6.2bar | ||||||||||
Process Volume | 2ml | 10ml | 100ml | 200ml | 5000ml | 10ml | 100ml | |||||
Hold-up Volume | <10μl | <50μl | <100μl | <200μl | <350μl | <25μl | <100μl | |||||
Inlet | Female Luer Lock | 7~13 mm stepped hose barb connection with 6:100 Luer slip | Female Luer Lock | |||||||||
Outlet | Male Luer Unlock | Male Luer Unlock | ||||||||||
Flow Direction | Flow should enter from the inlet | Both is fine | Flow should enter from the inlet | |||||||||
Temperature | Maximum Operating Temperature 131℃ | 131℃ | ||||||||||
Sterilization | Autoclave at 121℃ at 1 bar for 20 minutes/EO/Gamma | By EO or autoclave cycles of 30 min at 123℃. | Autoclave at 121℃ at 1 bar for 20 minutes/EO/Gamma |