VFD300 Economical General use frequency inverter
1,Support Applicable motors: AC induction motor, permanent magnet synchronous motor (PMSM)
2 High performance open loop and close loop vector control (support different kinds of encoders)
3.High torque control in low frequency 0.5Hz/150%(SVC), and 0Hz/180%(FVC)
real vector control with three hall sensor current detecting
4.Support 2 analog input 0-10v 4-20MA and two analog output as well as support IO expansion card
5. Protections: Over-voltage stall, under-voltage, current limit, overload, overheat, over speed, over-voltage, etc.
6.Support PID with fastest response
7 Support RJ45 Cables and standard keypad support 100m control
8 fast auto tuning less than 1 minutes
Item | Specifications | ||
Standard functions | Maximum frequency | 0~3200.00Hz | |
Carrier frequency | 0.5–16 kHz(The carrier frequency is automatically adjusted based on the load features.) | ||
Input frequency resolution | Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.025% | ||
Control mode | Sensor-less flux vector control (SFVC) Closed-loop vector control (CLVC) (+PG Card) Voltage/Frequency (V/F) control | ||
Startup torque | G type: 0.3Hz/150% (SFVC) ; 0 Hz/180% (CLVC) P type: 0.5Hz/100% | ||
Speed range | 1: 200 (SFVC) | 1:1000 (CLVC) | |
Speed stability accuracy | ± 0.5% (SFVC) | ± 0.02% (CLVC) | |
Torque control accuracy | ±5% (CLVC) | ||
Overload capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current P type: 60s for 120% of the rated current, 3s for 150% of the rated current | ||
Torque boost | Auto boost; Manual boost: 0.1%~30.0% | ||
V/F curve | Straight-line V/F curve Multi-point V/F curve N-powerV/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square) | ||
V/F separation | Two types: complete separation; half separation | ||
Acceleration/deceleration curve | Straight-line ramp S-curve ramp Four groups of acceleration/deceleration time with the range of 0.00s~65000s | ||
Standard functions | DC braking | DC braking frequency: 0.00 Hz ~ maximum frequency Braking time: 0.0~100.0s Braking trigger current value: 0.0%~100.0% | |
JOG control | JOG frequency range: 0.00Hz~50.00 Hz JOG acceleration/deceleration time: 0.00s~65000s | ||
Built-in PLC, multiple speeds | It realizes up to 16 speeds via the simple PLC function or combination of DI terminal states. | ||
Built-in PID | It realizes closed loop control system easily. | ||
Auto voltage regulation (AVR) | It can keep constant output voltage automatically when the mains voltage fluctuation. | ||
Overvoltage/ Over current stall control | The current and voltage are limited automatically during the running process so as to avoid frequently tripping due to overvoltage/over current. | ||
Rapid current limit function | It can auto limit running current of frequency inverter to avoid frequently tripping. | ||
Torque limit and control | (Excavator characteristics) It can limit the torque automatically and prevent frequently over current tripping during the running process. Torque control can be implemented in the VC mode. | ||
Individualized functions | High performance | Control of asynchronous motor is implemented through the high-performance current vector control technology. | |
Instant power off not stop | The load feedback energy compensates the voltage reduction so that the frequency inverter can continue to run for a short time. | ||
Rapid current limit | To avoid frequently over current faults of the frequency inverter. | ||
Timing control | Time range: 0.0~6500.0 minutes | ||
Multiple communication protocols | Currently supports communication bus via Modbus-RTU and later will support PROFIBUS-DP, CANopen, etc. | ||
Motor overheat protection | The optional I/O extension card enables AI3 to receive the motor temperature sensor input (PT100, PT1000) so as to realize motor overheat protection. | ||
Multiple encoder types | It supports incremental encoder and encoders such as differential encoder, open-collector encoder, resolver, UVW encoder, and SIN/ COS encoder. | ||
Advanced background software | It supports the operation of frequency inverter parameters and virtualoscillograph function, by which the state of frequency inverter can be monitored. | ||
Run | Running command giving | key panel Control terminals Serial communication port You can switch between these giving in various ways. |