Model | M0075G3 |
Power range | Three phase AC 380V (-15%~+30%) 0.75~500KW |
Output Frequency Range | 0~600Hz |
Control Mode | V/F Control, Sensorless Vector Control, Torque Control |
Starting Torque | 0.5Hz/150%(SVC), 1Hz/150%(V/F); |
Communication port | RS-485, which support MODBUS protocol |
Vibration | Less than 5.9m/s |
Fault Protection | protect from over current, over voltage, under voltage, over temperature, phase failure, over load etc. |
Item | Specifications | ||
Basic function | Over load capability | G type:150% rated current 60s;180% rated current 3s | |
P type:120% rated current 60s;150% rated current 3s | |||
Torque boost | Auto torque boost function; Manual torque boost 0.1%~30.0% | ||
V/F curve | Linear V/F, multi-point V/F and square V/F curve(power of 1.2,1.4,1.6,1.8,2) | ||
V/F separation | 2 ways: separation and semi-separation | ||
Acc./dec curve | Straight line or S curve acceleration and deceleration mode, | ||
Four kinds of acceleration and deceleration time. Acceleration and deceleration time range from 0.0s to 6500.0s | |||
DC braking | DC braking frequency:0.00Hz to maximum frequency. Braking time:0.0s to 36.0s | ||
Brake current value:0%-100% | |||
Jog frequency range:0.00Hz~50.00Hz; | |||
Jog acceleration/deceleration:0.0s~6500.0s. | |||
Simple PLC | It can realize at maximum of 16 segments speed | ||
Basic function | Multiple segment speed running | Running via the built-in PLC or control terminal. | |
Built-in PID | It is easy to realize process-controlled closed loop control system. | ||
Auto voltage regulation (AVR) | It can keep constant output voltage automatically in the case of change of network voltage. | ||
Over-voltage/current stall control | It can limit the running voltage/current automatically and prevent frequent over-voltage/current tripping during the running process. | ||
Quick current limit | Minimize the over-current fault, protect normal operation of the AC Drive. | ||
Torque limit & control | "Excavators" characteristics, automatically limit torque during operation, prevent frequent over-current tripping. Closed loop vector mode can realize the torque control. | ||
Personalized function | Instantaneous stop non-stop | When instantaneous power off, voltage reduction is compensated through load feedback energy, which could make AC Drive keep running in a short period of time. | |
Rapid current limit | To avoid AC Drive frequent over-current fault. | ||
Timing control | Timing control function:set time range 0Min~6500.0Min. | ||
Running | Operation panel reference, control terminal reference and serial communication port reference. These channels can be switched in various modes. | ||
Frequency source | There are totally eleven types of frequency sources, such as digital reference, analog voltage reference , analog current reference, pulse reference, MS speed, PLC, PID and serial port reference. | ||
5 digital input terminals. | |||
2 analog input terminals. | |||
1 supporting 0-10V voltage input or 0~20mA current input terminal. | |||
2 digital output terminals. | |||
2 relay output terminals. | |||
2 analog output terminals, supporting 0~10V voltage output or 0~20mA current output. | |||
Keyboard operation | Keyboard potentiometer | Equipped with keyboard potentiometer or coding potentiometer. | |
Keyboard operation | Protection function | It can implement power-on motor short-circuit detection, input /output phase loss protection, over current protection, over voltage protection, under voltage protection, overheating protection and overload protection. | |
Environment | Using place | Indoor, and be free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt. | |
Altitude | Below 1000m | ||
Ambient temperature | -10 ℃ to +40 ℃ (Derating use when under ambient temperature of 40 ℃ to 50 ℃) | ||
Humidity | Less than 95%RH,without condensing | ||
Vibration | Less than 5.9m/s (0.6g) |