Model | HA-IO400AF-CV24V/TP | ||||||
Voltage Range | AC90-265V | ||||||
Limited Voltage | 305VAC | ||||||
Power Factor | >0.95 | ||||||
T.H.D | <10% | ||||||
Efficiency | 90% | ||||||
Output | Rate Power | 400W | 350W | 400W | |||
Rate Current | 16.6A | ||||||
DC Voltage | 24V | ||||||
Current Accuracy | ±3% | ||||||
Power-on Time | <0.5S | ||||||
Protection | Short Circuit | constant voltage mode, recover automatically after fault condition is removed | |||||
Over Loading | ≤120% constant voltage limiting, recover automatically after fault condition is removed | ||||||
Over Temperature | 100℃±10℃ Shut down o/p voltage, recovers automatically after temperature goes down | ||||||
Others | Ta | 40℃ | |||||
Tc | 80℃ | ||||||
IP rating | IP67 | ||||||
Life span | 50000hours | ||||||
Warranty | 5 years | ||||||
Notes | 1. All parameters NOT specially mentioned are measured at 230VAC input , rated load and 25℃of ambient temperature. 2. Tolerance: includes set up tolerance, line regulation and load regulation . 3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. |