Model | S-350-5 | S-350-12 | S-350-15 | S-350-24 | S-350-27 | S-350-48 | ||||||
DC output voltage | 5V | 12V | 15V | 24V | 27V | 48V | ||||||
DC output current | 0-50A | 0-29A | 0-23.2A | 0-14.6A | 0-13A | 0-7.3A | ||||||
Wave and noise | 100mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | ||||||
Inlet stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||||||
Load stablity | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||||||
Efficiency | 78% | 80% | 80% | 82% | 82% | 83% | ||||||
Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% | ||||||
AC input voltage range | 90~132VAC 180~264VAC 47~63Hz 255~373VDC | |||||||||||
AC Impact current | Cold-start current 30A/230V | |||||||||||
Setup rise hold up time | 200ms, 50ms, 20ms/230VAC at full load | |||||||||||
Withstand voltage | Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC | |||||||||||
Isolation resistance | Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ | |||||||||||
Working temperature and humidity | -10°C~+60°C(Refer to output derating curve),20%~90%RH | |||||||||||
Overall dimension | 215*115*50mm | |||||||||||
Weight | 1.01Kg | |||||||||||
Note: | ||||||||||||
1.The testing condition for the paramenter above is :230VAC input,rated load,25°C70% RH.Humidity. | ||||||||||||
2.Error.include the setting error,line stability and load stability.(Note:5). | ||||||||||||
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. | ||||||||||||
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. | ||||||||||||
5.Load stability test:the load is from 0% to 100%. | ||||||||||||
6.C2,3,6must be knocked down. |