Mounting surface | ISO4401 standard 06,10 |
Max flow | 40L/Min(06) and 100L/Min(10) When the pressure drop is equal to 70 bar |
Max pressure | 31.5 MPa |
Structure | Direct acting spool valve with steel sleeve |
Drive | Proportional solenoid valve with position controller |
Type of installation | Base plate, mounting hole structure diameter 6 (ISO 4401-03-02-0-94) |
Installation position | Any |
Ambient temperature range | -20...+50 °C |
Weight | 2.3kg |
Seismic, detection conditions | The maximum 25g vibrates in three dimensions(24h) |
Electrical parameters | ||
Relative power-on duration | 100% | |
Supply voltage | 24Vnom( External electrical amplifier ) | |
Protection grade | Accord with DIN 40050 standards based IP 65 | |
Electromagnet connection | Socket DIN 43650/ISO 4400, M16x1.5( 2P+PE ) | |
Displacement sensor wiring | Socket Pg7(4P) | |
Maximum wiring current | 2.7A | |
Coil resistance R20 | 2.5Ω | |
Maximum power consumption, when 100% load and working temperature | 40VA | |
Motion detector DC/DC-technology | Power supply:+15V/35mA;-15V/35mA Signal:0...±10V( RL≥10kΩ ) |
Steady state/Dynamic | ||
Hysteresis | ≤0.2% | |
Manufacturing tolerance, against qmax | <10% | |
Response time, for signals Variation 0...100% | <10% ms | |
Temperature drift | Zero displacement <1%, ∆T=40°C | |
Zero adjustment | Factory setting ±1% |