Part Number | SMWC50-0350SS/SD | SMWC50-0700SS/SD | SMWC50-1050SS/SD | SMWC50-1400SS/SD |
| ||||||
| OUTPUT | DC VOLTAGE | 86-143V | 43 -71V | 29-48V | 21-36V | |||||
| CONSTANT CURRENT REGION Note.4 | 350mA | 700mA | 1050mA | 1400mA | ||||||
| RATED POWER | 50W | |||||||||
| RIPPLE & NOISE(max.) Note.2 | 6.8V | 4.8V | 3.8V | 3.7V | ||||||
| CURRENT TOLERANCE Note.3 | ±5.0% | |||||||||
| LINE REGULATION | ±2.0% | |||||||||
| LOAD REGULATION | ±3.0% | |||||||||
| SETUP, RISE TIME(Typ.) Note.7 | 1500ms/50ms 115VAC at full load 500ms/50ms 230VAC | |||||||||
| INPUT | VOLTAGE RANGE Note.5 | 90 ~305VAC | ||||||||
| FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
| POWER FACTOR(Typ.) | 0.99@115VAC 60HZ | 0.99@115VAC 60HZ | 0.99@115VAC 60HZ | 0.99@115VAC 60HZ | ||||||
| EFFICIENCY(Typ.) | 90% | 89.5% | 89% | 88.5% | ||||||
| AC CURRENT(Typ.) | 0.6A/115VAC 0.3A/230VAC | |||||||||
| INRUSH CURRENT(Typ.) | COLD START 48A ( Twidth=270us measured at 50% Ipeak ) at 230VAC | |||||||||
| LEAKAGE CURRENT | <0.75mA/265VAC | |||||||||
| PROTECTION | OVER CURRENT Note.4 | 95 ~ 108% | ||||||||
| Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
| SHORT CURRENT | Hiccup mode, recovers automatically after fault condition is removed | |||||||||
| OVER VOLTAGE | 160V | 90V | 63V | 48V | ||||||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||
| OVER TEMP. | Hiccup mode, recovers automatically after fault condition is removed | |||||||||
| ENVIRONMENT | WORKING TEMP. | -35 ~ +70℃ (Refer to “Derating Curve”) | ||||||||
| WORKING HUMIDITY | 10 ~ 100% RH non-condensing | |||||||||
| STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 5 ~ 100% RH | |||||||||
| TEMP. COEFFICIENT | ±0.03%℃ (0~50℃) | |||||||||
| VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||||
| SAFETY & EMC | SATETY STANDARDS Note.6 | UL8750, UL935, UL1012, CSA-C22.2 No.107.1, EN61347-1, EN61347-2-13 | ||||||||
| WITHSTAND VOLTAGE | I/P – O/P: 3.75kVAC,I/P-FG:2KVAC | |||||||||
| ISOLTATION RESISTANCE | I/P – O/P: 100M Ohms / 500VDC /25℃ / 70% RH | |||||||||
| EMC EMISSION | Compliance to EN55015, EN61000-3-2 Class C (≥60% load); EN61000-3-3 | |||||||||
| EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 2kV), criteria A | |||||||||
| OTHERS | MTBF | 340khrs min. MIL-HDBK-217F (25℃) | ||||||||
| DIMENSIION | 117(121)*49*33MM(L*W*H) | |||||||||
| PACKING | 380±10g |
We will arrange to ship your orders with3- 15 working days after payment
confirmed:
1. EMS: Reach most countries takes about 6- 8 days
2. DHLFedex/UPS: Reach most countries takes about3 - 5 days
Valid Tracking number will be provided in the next day.
3. By Air Transportation and By Sea for bulk orders
The normal LED Driver packing is use carton (size: L * W * H).If exported to European countries, cartons will be fumigated, according to the special requirements of the customer.