Dry coolers are utilized for the cooling of processing liquids, generally pure or ethylene glycol water, particularly in refrigeration applications, air-conditioning or industrial processes such as free-cooling and the cooling of liquids that circulate inside industrial molding dies.
The coolers are so called "dry" since they utilize air as a secondary fluid. Compared to solutions that function with water, such as cooling towers, air avoids the problems resulting from the formation of incrustations.
Applications: Process cooling, air-conditioning and commercial cooling
Cooling capacity: 35-1044 kW
Fans: Maintenance free Ziehl-Abegg fans, EMB fan or Chinese fan.
Coil: aluminum fins 0,15 mm, copper tubes diameter 12 or 16 mm, fin spacing 2,1 mm
Casing: galvanized plate, spray
Cooling media: Water / glycol mixes and others
Air direction: vertical or horizontal
Performance ranges | Air cooled condensers capacity: from 148 to 921 kW * Airflow: from 76459 to 351663 m3/h Dry coolers: customized on demand | |
Coil features | High heat exchange efficiency. Designed with special "Air Intake" profile aluminum fins and inner grooved copper tubes, Copper tube 12.7mm Fin spacing: 2,1 mm | |
Casing features | galvanized plate, spray | |
Fan motor features | Diameter: 630mm Voltage: 400V/3P/50Hz Fan brand: Ziehl-Abegg, can be customized on demand | |
Testing | Heat exchanger are supplied clean and tested at a pressure of 3.0 Mpa. | |
Published capacity: ethylene glycol 20%, inlet temperature 45C, outlet temperature 40C, air inlet temperature 35C |
some standard dry cooler technical parameters as below, For more informations, please contact me at 0086 13916251589.
Dry Cooler Type | D2-148-4x630 | D2-228-6x630 | D2-276-6x630 | D2-310-8x630 | D2-364-8x630 | D2-392-10x630 | ||||||
Capacity | Water | KW | 147.99 | 227.85 | 276.53 | 309.85 | 364.07 | 391.99 | ||||
20% Et. Glycol | KW | 142.42 | 219.09 | 270.22 | 301.18 | 354.64 | 383.3 | |||||
Air flow | M3/h | 76459 | 114686 | 108188 | 152911 | 144255 | 191136 | |||||
Fan | No. X φ | 2x2x630 | 2x3x630 | 2x3x630 | 2x4x630 | 2x4x630 | 2x5x630 | |||||
Fan motor 380/3N/50HZ | A | 20.4 | 30.6 | 30.6 | 40.8 | 40.8 | 51 | |||||
Sound pressure level | dB(A)10m | 64 | 66 | 66 | 67 | 67 | 68 | |||||
Dimension | L | mm | 2186 | 3250 | 3250 | 4250 | 4250 | 5250 | ||||
H | mm | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | |||||
D | mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | |||||
D1 | mm | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | |||||
L1 | mm | 963 | 963 | 963 | 963 | 963 | 963 | |||||
L2 | mm | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | |||||
L3 | mm | 1963 | 2963 | 2963 | 3963 | 3963 | 4963 | |||||
Connections inlet/onlet φ | mm | 2XDN50 | 2XDN65 | 2XDN80 | 2XDN80 | 2XDN100 | 2XDN100 | |||||
Product weight(empty) | kg | 769 | 1134 | 1261 | 1498 | 1673 | 1864 |
• Unique floating coil design avoids leakage caused by thermal expansion and contraction.
• Staggered fin pattern design and corrugated fin enhance air flow turbulence
• Inner-grooved copper tube increase heat transfer area and enhance heat transfer
• Optimized flow pass design ensure fully heat exchange with refrigerant
• Equipped with 2nd generation owl-wing fan motor as standard. It features with low noise level, large volume flow and low energy consumption. Ready for dual speed connection.
• Outdoor type powder coated casing made of galvanized sheet metal and stainless steel bolts provide a high resistance to corrosion.
• Optional features:
§ EC variable speed fan motor, to save great energy
§ ZAplus/AxiTop for greater volume flow and extreme silence
§ Adiabatic system significantly reduce energy consumption in summer
§ Epoxy coated or hydrophilic aluminum fin suitable for coastal or high corrosion area
§ Fluid dry cooler
§ Clean stainless steel tube and aluminum fin coil for cooling deionized water.
Unique floating coil design avoids leakage caused by thermal expansion and contraction.
Tell us the datas as following:
A. Required water inlet temperature?
B. Required water outlet temperature?
C. Water flow?
D.Ambient temperature?
E.Supply power(voltage-Hz-phase)
G.Any other requirements ?
CONTACT Bella 0086 13916251589
The advanced rippled-corrugated HI-F design creates a state of continuous turbulence which effectively reduces the boundary layer formation. The exclusive rippled edge
instantly deflects the incoming air to create initial turbulence.
A succession of corrugations across the fin depth, in conjunction with the staggered tubes, increases the turbulating effect and eliminates the "dead spots" behind the tubes. In this manner, the HI-F design establishes a high standard in heat transfer efficiency yielding sharply increased performance.
The term "energy efficient," which is used to describe how well a system utilizes energy, has become a common expression in the HVAC industry.
The need to cut operating energy expenses is met by the E-F fin surface.
The smoother fin design of the E-F surface results in lower operating costs over the life of the equipment.
Contact Bella 0086 13916251589
The more moving air in contact with the tubes in the coil, the more performance obtained from the total available surface.
The staggered tube design exposes the tubes to more moving air than the in-line design. The geometry of the staggered tube design also allows the rows to be spaced closer together. This results in a more compact coil providing higher capacities.