Technical parameter
Product name:Protection Circuit Module
Model No:PCM-L02S05-D79
For 2S 18650/18500 Lithium-ion/Lithium Polymer/LiFePO4 Battery Packs
Product Feature:
1. Suitable for 2S Lithium-ion/Lithium Polymer/LiFePO4 Battery Packs;
2. Measuring IC adopts BQ4050/BQ40Z50, which can read parameters such as voltage, capacity, current, temperature and cycle times.
3. Overcharge, over discharge, short circuit, over current, temperature protection, etc.
4. Maximum continuous working current 5A, charging and discharging at the same port;
No. | Test item(Test at normal temperature 25±2℃ ) | Criterion | |
1 | Communication Interface | SMBus | |
2 | Capacity | Designing battery capacity(PCM) | 2200mAh |
Max capacity(Battery pack) | 7000mAh | ||
Min capacity(Battery pack) | 500mAh | ||
External capacity Indication | LED | ||
Gas gauge algorithm | CEDV | ||
3 | Voltage | Charging voltage | DC:12.6V CC/CV(4.2v/Cell) |
4 | Balance | Cell-balance window | 100mv |
Balance Resistance | 100R | ||
CCC Voltage threshold | 3.27V | ||
5 | Supply Current | Normal mode(Firmware running, no flash writes) | 500uA |
Sleep mode | 300uA | ||
Shutdown mode | 1uA | ||
Maximal continuous charging current | 5A | ||
Maximal continuous discharging current | 5A | ||
6 | Over-charge Protection (single cell) |
Over-charge detection voltage | 4.25±0.05V |
Over-charge detection delay time | 1S | ||
Over-charge release voltage | 4.05±0.05V | ||
7 | Over-discharge protection (single cell) |
Over-discharge detection voltage | 2.50±0.05V |
Over-discharge detection delay time | 1S | ||
Over-discharge release voltage | 3.00±0.05V | ||
9 | Short protection | Detection condition | Exterior short circuit |
Short protection Current | 6~10A | ||
Discharge short-circuiting detection delay time | 200-800us | ||
Release condition | Cut load | ||
10 | Resistance | Protection circuitry | ≤30mΩ |
11 | Temperature protection | Charge temperature(1st Level Safety) | 55℃ |
Charge temperature detection delay time (1st Level Safety) |
2s | ||
Charge release temperature(1st Level Safety) | 50℃ | ||
Discharge temperature (1st Level Safety) | 60℃ | ||
Discharge temperature detection delay time (1st Level Safety) |
2s | ||
Discharge release temperature(1st Level Safety) | 50℃ | ||
Charge temperature (2nd Level Safety) | 65℃ | ||
Charge temperature detection delay time (2st Level Safety) |
0s | ||
Discharge temperature(2st Level Safety) | 75℃ | ||
Discharge temperature detection delay time (2st Level Safety) |
0s | ||
Operating temperature | -40~+85℃ | ||
Functional temperature | -40~+110℃ | ||
Storage temperature range | -65~+150℃ | ||
Dimension | L54*W12*T4mm | ||
B+:Battery+ | |||
B-:Battery- | |||
SMBD:SMBus data line | |||
SMBC:SMBus clock line | |||
P+:Charge+/discharge+ | |||
P-:Charge-/discharge- |