220v 500va 1000va line interactive ups circuit diagram
1.line interactive ups
2.DC voltage : 12v 24v 48v
3.Output voltage:220v
4.Remote control function--- option
5.Over high or over low voltage input & output protection
6.Nominal capacity:500va/400w 1000va/800w
7.RS232 communication monitoring interface--- option
8.Overload/ over temperature output protection
9.Display panel :lcd or led (optional)
10.Wave form : pure sine wave
Model |
500va |
1000va |
1500va |
2000va |
3000va |
4000va |
5000va |
6000va |
Continuous power |
400w |
800w |
1200w |
1600w |
2400w |
3200w |
4000w |
4800w |
Surge power |
800w |
1600w |
2400w |
3200w |
4800w |
6400w |
8000w |
9600w |
Work mode |
Low frequency line interactive |
|||||||
Phase |
Single phase |
|||||||
Transfer time |
≤5ms |
|||||||
Max efficiency |
≥92%(full load) |
|||||||
INPUT |
||||||||
Voltage range |
145- 275Vac (single phase L+N+G) |
|||||||
Input power factor |
>0.8 |
|||||||
Input Frequency |
50hz/60hz±10% |
|||||||
OUTPUT |
||||||||
Input AC voltage |
220vac/110vac ±25 % (single phase L+N) |
|||||||
Frequency |
50Hz/60hz ±1% (battery mode) |
|||||||
COSΦ |
0.8(lag) |
|||||||
Waveform |
Pure Sine Wave |
|||||||
Wave Form distortion |
Linear load<3%; Non linear load<5% |
|||||||
CREST FACTOR RATIO |
>3:1 |
|||||||
CHARGER |
||||||||
Charge Current |
1-10A (optional) |
|||||||
Charge Model |
First constant current, then constant voltage; float charge and average charge automatic transfer |
|||||||
Float Charge |
13.7V |
27.5v |
55v |
|||||
Average Charge |
14.2V |
28.4v |
56.8v |
|||||
BATTERY |
||||||||
Rated battery voltage |
12VDC |
|||||||
Battery Type |
lead acid maintenance-free battery |
|||||||
Battery capacity |
7-999AH adjustable |
|||||||
External battery Qty. |
12V/1pcs |
12v/2pcs |
12V/4pcs |
|||||
PROTECTION |
||||||||
Input protection |
Over voltage, and over frequency |
|||||||
output protection |
Over current, short-circuit, battery low/high voltage |
|||||||
Overload protection |
<120%→30s <150%→10s >150%→0s |
|||||||
Battery protection |
Over-charge and over discharge |
|||||||
Temperature protection |
UPS Internal and external environment over temperature protection |
|||||||
HW FAILSAFE |
When auxiliary power abnormal, the relay jump and fuse disconnect; The over-voltage and over-current protection of the internal parts |
|||||||
ENVIRONMENT |
||||||||
Ambient temperature |
0 - 50oC |
|||||||
Humidity |
20—90% noncondensing |
|||||||
Noise |
≤40DBA(for 1 meter distance) |
|||||||
Altitude |
<1000m (Each additional 100 meters, power down 1%. Maximum 4000 m) |
|||||||
Protection Class |
IP 21 |
|||||||
GENERAL |
||||||||
Net Weight(kg) |
9kg |
11.7kg |
14kg |
32kg |
35kg |
36kg |
37kg |
39kg |
Enclosure Size (WxDxH) mm |
320*145*235mm |
440*245*300mm |
||||||
OPTIONAL EXTRA FUNCTION |
||||||||
Communication |
RS232 |
|||||||
RMON ( remote monitoring ) |
SNMP |
|||||||
Display panel |
LED: green light for mains output; yellow light for inverter output; red light for faults LCD: input/output battery voltage; input/output frequency; number of load and condition |