220V Single Phase to 380V 3 Phase Converter 15KW AC Motor Drive Inverter 50Hz 60Hz VFD
Model and Technichal Parameters
Voltage | Inverter Model | Rated capacity (kVA) | Output C(A) | Adaptable motor (KW) |
220V | XXX-2S0007 | 1.4 | 4 | 0.75 |
XXX-2S0015 | 2.6 | 7 | 1.5 | |
XXX-2S0022 | 3.8 | 10 |
2.2 |
Specifications
Item |
Specifications |
|
Input |
Rated Voltage/Frequency |
Single Phase:220V,Three Phase:220V;50Hz/60Hz |
Allowable Variablerange |
Voltage:-20%~+20% ,Voltage imbalance rate:<3% ,Frequency:±5% |
|
Output |
Rated Voltage |
0~220V |
Voltage Range |
0Hz~400Hz |
|
FrequencyResolution |
0.01Hz |
|
Overload capacity |
150% Rated Current:1 minute,180%:1 second ,200%:Instantaneous protection |
|
Basic Functions |
modulation mode |
Optimization Space Voltage Vector PWMmodulation |
FrequencyAccuracy |
Digital Setting:Maximum Frequency ×±0. 01%; |
|
FrequencyResolution |
Digital Setting:0.01Hz;Analog Setting:Maximum Frequency ×0.1% |
|
Start upFrequency |
0.40Hz~10.00Hz |
|
Torque boost |
AutomaticTorque boost |
|
V/F Curve |
Linear V/F Curve,Square V/F Curve,Customized V/F Curve |
|
Acceleration and deceleration Time |
Optional Hourly basis(Min/Sec) ,The longest:3600(0.1-3600) |
|
AC Braking |
Optional during starting and halting::Operation frequency:0~20.00Hz |
|
Inching |
Inching frequency range:0.1Hz~50.00Hz, |
|
Built in PID |
Composition closed-loop control system easily for controlling pressure and flux progress |
|
Multistage speed running |
Realizing multistage speed via built in PLC or control terminal |
|
Textile swing frequency |
Swing frequency Function can realize set or regulate range of oscillation |
|
Automatic Voltage Regulation(AVR) |
Output constant voltage when voltage change in grid |
|
Automatic Energy-saving running |
Automatic optimize V/F Curve base on load and realize Energy-saving running |
|
Automatic limit Current |
Automatic limit Current during running ,avoid frequently overload trip |
|
Communication |
RS485 Standard Interface,supporting two formats MODBUS protocol :ASCII and RTU With Master-Slave linkage function. |
|
Operation Functions |
Running command channel |
Operation Interface setting,Control terminal setting, Serial port setting.Can change three modes. |
Frequency Setting Channel |
Keypad analog Potentiometer setting;Keypad:up,down setting;Function code digital setting;Serial port setting;Terminal UP/DOWN Setting;Analog Voltage setting;Analog current setting,Pulse setting;Combination setting;Can change multiple modes |
|
Switch Input channel |
Positive inversion instruction;5 channels programmable switch input,can set 35 functions individually. |
|
Analog Input channel |
2 channels analog signal input,4~20mA,0~10V optional |
|
Analog Output channel |
Analog signal output, 4~20mA or 0~10Voptional,can set frequency and output frequency |
|
Operation Interface |
LED Digital display |
Display set frequency,output voltage,output current,etc parameters |
External meter display |
Output frequency,output current,output voltage etc |
|
Protection |
Over Current protection;Over Voltage protection;Under Voltage protection; Over heat protection;Overload protection |
|
Optional accessories |
Braking combination;Remote operation interface;Remote electric cable; |
|
|
Installation location |
Indoor, ,free from direct sunlight, dust, corrosive gas,Oiliness gas, water vapour |
Altitude |
Less than 1000m(More than 1000m need derating) |
|
temperature |
-10℃~+40℃ |
|
Ambient temperature |
Less than 90%RH,no water condenses |
|
Vibration |
Less than 5.9m/sec 2(0.6G) |
|
Storage temperature |
-20℃~+60℃ |
|
Structure |
Level of Protection |
IP20 |
Cooling-down method |
Forced air cooling |
|
Installation |
Wall-mount |