1. Competitive factory direct price, fast delivery.
2. The company has been focusing on R & D and production for 13 years, quality assurance
2. One-stop solution to the complete solar energy system can save your time and money.
3. Professional sales team, exported to more than 80 countries.
4. For large-scale solar power station projects, engineers can provide on-site guidance and installation services.
5. OEM service is acceptable and customized LOGO can be printed on the product.
HV-48 series is a new all-in-one hybrid solar charge inverter, which integrates solar energy storage &means charging energy storage and AC sine wave output.Thanks to DSP control and advanced controlalgorithm, it has high response speed, high reliability and high industrial standard.
Model | HF4830S60-H | HF4850S60-H | HF4835U60-H | HF4850U80-H |
AC mode | ||||
Rated input voltage | 220Vac/230Vac | 110Vac/120Vac | ||
Input voltage range | (170Vac~280Vac)±2%;(90Vac-280Vac)±2% | (90Vac-140Vac)±2% | ||
Frequency | 50Hz/60Hz(auto-sensing) | |||
Frequency Range | 47±0.3Hz~55±0.3Hz(50Hz)/57±0.3Hz~65±0.3Hz(60Hz); | |||
Overload/short circuit protection | Breaker | |||
Efficiency | >95% | |||
Conversion time(bypass and inverter) | 10ms(Typical value) | |||
AC reverse protection | yes | |||
Maximum bypass overload current | 40A | 63A | ||
Inverting mode | ||||
Output voltage waveform | Pure sine wave | |||
Rated output power(VA) | 3000(2600/2700/3000) | 5000(4350/4500/4800/5000) | 3500(2900/3000/3200) | 5000(4100/4300/4500) |
Rated output power(W) | 3000(2600/2700/3000) | 5000(4350/4500/4800/5000) | 3500(2900/3000/3200) | 5000(4100/4300/4500) |
Power factor | 1 | |||
Rated output voltage(Vac) | 230Vac(200/208/220/240Vac settable) | 120Vac(100/105/110Vac settable) | ||
Output voltage error | ±5% | |||
Output frequency range(Hz) | 50Hz±0.3Hz/60Hz±0.3Hz | |||
Efficiency | >90% | |||
Overload protection | (102%<load<125%)±10%:reporting error and turm off the output after 5 minutes; ((125%<load<150%)±10%:reporting error and turm off the output after 10 seconds;Load>150%±10%reporting error and turn off the output after 5 seconds; |
(102%<load<110%)±10%:reporting error and turn off the output after 5 minutes; (110%<load<125%)±10%:reporting error and turn off the output after 10 seconds; Load> 125%±10%reporting error and turn off the output after 5 seconds; |
||
Peak power | 6000VA | 10000VA | 5000VA | 7000VA |
Loaded motor capacity | 2HP | 4HP | 2HP | 3HP |
Output short-circuit protection | Breaker | |||
Specification of bypass breaker | 40A | 63A | ||
Rated battery input voltage | 48V(minimum start voltage 44v] | |||
Battery voltage range Power saving mode |
40.0Vdc~60Vdc ±0.6Vdc(undervoltage alarm/tumoff voltage/overvoltage alarm/overvoltage restoration.. settable LCD screen) Load s50W |
|||
AC charge | ||||
Battery type | Lead acid or lithium battery | |||
Maximum charge current | 60A | 40A | ||
Charge current error | ±5Adc | |||
Charge voltage range | 40~60Vdc | |||
Short-circuit protection | Breaker and blown fuse | |||
Breaker specification | 40A | 63A | ||
Overcharge protection | Turm off charge after 1min alarm | |||
Solar charge | ||||
Maximum PV opencircuit voltage | 500Vdc | 450Vdc | 500Vdc | |
PV operation voltage range | 120-500Vdc | 120-450Vdc | 120-500Vdc | |
MPPT voltage range | 120-450Vdc | 120-430Vdc | 120-450Vdc | |
Battery voltage range | 40-60Vdc | |||
Maximum output power | 4200W | 5000W | 4200W | 5000W |
Charge current range of solar energy(settable) | 0-60A | 0-80A | 0-60A | 0-80A |
Charge short-circuit protection | Blown fuse | |||
Wiring protection Authentication specification |
Inverse wiring protection | |||
Specification authentication | CEQEC62109),RoHs | |||
EMC authentication grade | EN61000 | |||
Operation temperature range | -15Cto 55℃ | |||
Storage temperature range | -25℃~60℃ | |||
Humidity range | 5%to 95%(Conformal coating protection) | |||
Noise | ≤60dB | |||
Thermal dissipation | Forced cooling with adjustable air speed | |||
Communication interface | USB/RS485(WiFi/GPRS)/dry node control | |||
Dimension(L*W*D) | 426mm*322mm*126mm | |||
Weight(kg) | 10.9 | 11.6 |
·Adopt full digital voltage and current double closed-loop control and advanced
SPWM technology to output pure sine wave.
·Two output modes, i.e. mains bypass and inverter output can achieve
uninterrupted power supply function.
·Available in 4 charging modes: Only Solar, Mains Priority, Solar Priority and
Mains & Solar hybrid charging.
·Advanced MPPT technology, with efficiency up to 99.9%.
· Wide MPPT voltage range.
·There is no commercial power or battery, and the solar energy has
independentloading function.
·With function of activating lithium battery with solar energy and AC mains
power,it supports connection of lead-acid battery and lithium battery.
·LCD screen design and 3 LED indicator lights dynamically display system
data andoperation states.
·ON/OFF rocker switch can control AC output.
·With power saving mode function, it can reduce no-load loss.
·Intelligent adjustable speed fan is adopted for efficient heat dissipation and
extended system life.
·Possessing multiple protection functions and 360° comprehensive protection.
·Possessing complete short circuit protection, overvoltage and undervoltage
protection, overload protection, back filling protection, etc.